Venmar Connaisseure C700 SERIES Installation Instructions Manual - 6. Install The Hood
8
6. INSTALL THE HOOD
CAUTION
After a power failure or during the range hood power up, a 5-second booting sequence is
executed. Wait for the control backlighting to turn off before use.
6.1
Run power cable to
installation location.
Position the hood in its
intended location. Using a
pen, mark the position of
the screws (as shown at
right). Remove the hood.
6.2
Install the first four no. 8 x 1/2’’ screws, leaving a 1/8’’ gap (do not install screws nos. 5, 6 and
7 yet).
6.3
Install the wire clamp and insert the power cable in the hood. Place the hood under the cabinet,
slide it in position and tighten the wire clamp to secure the cable. Make sure the adapter/
damper enters the duct opening. Tighten the first 4 screws completely, then add the last screws
(screws nos. 5, 6 and 7) in the center holes. Make sure the damper flap opens freely.
HD0413
1
7
6
5
4
2
3
7. CONNECT
WIRING
WARNING
!
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance
with all applicable codes and standards. Before connecting wires, switch power off at
service panel and lock service disconnecting means to prevent power to be switched on
accidentally.
HE0059
G
ROUND
SCREW
Connect cable to range hood wiring
using included wire connectors.
Connect BLACK to BLACK, WHITE to
WHITE and GREEN or BARE WIRE
to GREEN ground screw.
DO NOT
FORGET TO CONNECT THE GROUND.