Summary of EUROLINE

  • Page 1

    Page 1 (rev. 11/07) l113 read and save these instructions all hoods must be installed by a qualified installer installation instructions euroline/euroline pro island range hood read all instructions thoroughly before beginning installation warning - to reduce the risk of fire, electric shock, or inj...

  • Page 2: Ducting Do’S and Don’Ts

    Page 2 (rev. 11/07) l113 ducting do’s and don’ts never restrict the duct size. The island dual blower unit (t200) requires 8” round duct or equivalent (50 square inches). The island cluster blower unit (t400) requires 12” round or equivalent (113 square inches). Using the included vent-a-hood transi...

  • Page 3: Installation Details

    Page 3 (rev. 11/07) l113 installation details 1) read all instructions thoroughly before beginning installation. Note: these instructions apply to standard hoods only. Custom hoods may require additional specification consideration. 2) when installing an island range hood, it is recommended that the...

  • Page 4

    Page 4 (rev. 11/07) l113 centerline of hood 5" x 16" exhaust opening 8" transition opening centerline of hood vent holes electrical 7 3/4" 7 3/4" 12" transition opening 2 1/4" above top of hood 9" 16" 5" 8" round 8" round 18" 12" round 12" round 11 1/4" 8" round 8" round 8" round l e d o m e p y t s...

  • Page 5

    Page 5 (rev. 11/07) l113 installation details continued 9) raise the hood to its final position and attach it to the load-bearing framework in the ceiling using appropriate hardware or to the duct cover using the screws previously removed in step 3. 10) from inside the hood, using ul listed wire nut...

  • Page 6

    Page 6 (rev. 11/07) l113 venting accessories 6”,7”,8” 36” vp500 6” vp501 7” vp502 8” model dim 4 1/4” 3 1/4” 10” 3 1/4” 14” back vent elbow vp559 3 1/4”x10” model dim 10 to 7 transition 7” 7 1/2” 10” 3 1/4” model dim vp521 3 1/4” x 10”- 7” low profile roof jack (maximum 4/12 pitch) 16 3/4” 6 1/2” 16...