Vent-Axia Air Minder Plus User Manual - page 6
1:6 Filter
Check
(Alternates every 3 seconds with 1:1 display).
Filter inspection required of the Intake and Extract Filters.
The Heat Recovery Unit’s filters will require regular
inspection and cleaning. (Refer to the Heat
Recovery Unit’s fitting and wiring instructions).
To reset the automatic reminder, press and hold
down the ‘ ’ and ‘V’ keys for 10 seconds.
1:7 System
Failure
If a fault is found then the Air Minder Plus is turned
off and the service telephone number shown;
alternating with the Fault code number.
Fault code number
1= Intake Fan not running
2= Exhaust Fan not running
3= Neither Fan running
Add
8 = Temperature Sensor T1 faulty
16 = Temperature Sensor T2 faulty
For example, a fault code of 10 indicates both
Exhaust Fan and Temperature Sensor T1 at fault.
For assistance contact your installer or service
provider and quote the Fault code number.
1:8 System
Running
Time
To display the Total Running Time (Hours).
Press and hold the ‘ ’,’V’ and ‘SET’ Keys for 5 seconds.
The display will return to normal running display
after 10 seconds.
Note:
The timer cannot be re-set. In the event of power
failure total time will be retained.
2:1. Press the ‘Boost Key’ to override the current speed
setting (Low or Medium depending on the Time Cycle).
The display will change from the default setting to
the screen below:
2:2. Press the ‘Boost Key’ again and the controller will
return the current speed setting (Low or Medium
depending on the Time Cycle).
Note:
If the ‘Boost Key’ is not pressed to return the speed
to the current setting, the speed will return to
default speed at the next change of the time cycle.
4
4
AIR MINDER plus
SET
>
>
F
C h
c k
i l t
e
e r
SET
>
>
2
e
e
S
3
v
r
i
P
2
0
c
h
0
n
o
e
1
4 5 6 7 8 9
SET
>
>
u
g
R
n
n
i
T
H
n
i
e
m
H H H H
u
>
>
e
u
T
d
e
M
i
SET
1
1
1 :
5
e
e
p
S
d
m
B o o s t
S p e e d
5
1
1
1
e
u
T
:
Boost key
V
V
1
p
u
T u
M e d i
1
m
S
: 1 5
e e d
e
Default Setting
2 : B O O S T S P E E D O V E R R I D E ( M A N U A L )