    45812a printed in canada 05-07-2016 installation and operation manual me150 safety tested according to ulc s610 and ul 127 standards by an accredited laboratory e.P.A. Standards exempt www.Occanada.Com manufactured by: stove builder international inc. 250 rue copenhague, saint-augustin-de-desmaures ...

  • Page 2

    2 me150 - installation and operation manual thank you for choosing this ventis fireplace as one of north america’s largest and most respected wood stove and fireplace manufacturers, stove builder international takes pride in the quality and performance of all its products. We want to help you get ma...

  • Page 3

    Me150 - installation and operation manual 3 table of contents 1 introduction ..................................................................................................................... 4 1.1 me150 wood fireplace specifications ..................................................................

  • Page 4: Introduction

    4 me150 - installation and operation manual 1 introduction this manual contains all the information required for safe, efficient installation and use of your ventis fireplace. Read carefully all the instructions contained herein and keep this manual handy so you may refer to it whenever necessary. B...

  • Page 5

    Me150 - installation and operation manual 5 1.2 views with measurements.

  • Page 6: Installation

    6 me150 - installation and operation manual 2 installation this fireplace is designed and approved for installation with the brand of chimney mentioned in table 1 with a minimum of 15’ (4.6 m) and maximum of 45’ (13.5 m) in height. No other device must be added to the chimney connected to the firepl...

  • Page 7

    Me150 - installation and operation manual 7 2.1 fireplace installation 1. Before beginning installation, remove the fireplace trim to protect it from damage. The fastening screws are located behind the upper and lower louvers. Make sure no masonry products or acids come into contact with the trim as...

  • Page 8

    8 me150 - installation and operation manual 7. The opening must be at least 24" (610 mm) away from any wall at a right angle with the appliance’s face (see figure in section 4: fireplace finish). 8. Place the appliance in the desired location. It must directly abut against the finished wall and not ...

  • Page 9

    Me150 - installation and operation manual 9.

  • Page 10: Venting System

    10 me150 - installation and operation manual 3 venting system 3.1 general information the venting system is the engine that drives your wood heating system. Even the best fireplace will not function safely and efficiently as intended if not connected to a suitable chimney. The heat in the flue gases...

  • Page 11

    Me150 - installation and operation manual 11 3.3 chimney installation notes 1. If possible, install an interior chimney as it will provide better performance. In areas with continuous temperatures below − 18 ° c (0 ° f), the use of an exterior chimney increases the likelihood of operating problems s...

  • Page 12

    12 me150 - installation and operation manual 7. Deviations should be avoided whenever possible, especially the most pronounced. Each deviation adds some restriction to the chimney system and may lead to draft problems. Offsets of 30 degrees are allowed in the united-states and up to 45 degrees in ca...

  • Page 13

    Me150 - installation and operation manual 13 18" 457.21mm 18" 457.2mm 16" 406.4mm 16" 406.4mm 18" 457.2mm.

  • Page 14

    14 me150 - installation and operation manual 3.4 chimney installation instructions always refer to the chimney manufacturer’s installation manual to ensure a safe installation. Some non- illustrated parts may be required. Examples of typical chimney installation a to insure a good draft, it is recom...

  • Page 15

    Me150 - installation and operation manual 15 direct installation exterior offset installation.

  • Page 16

    16 me150 - installation and operation manual interior offset installation 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass. Use a plumb bob to line up the center of the holes. Make sure that the size of the floor and ceiling holes are in accordance with the chimn...

  • Page 17

    Me150 - installation and operation manual 17 4. Every time the chimney passes through a ceiling or a wall, install the appropriate firestop. When you reach the desired height, install the roof support (not illustrated). (refer to instructions included with the support). 5. Then, put the roof flashin...

  • Page 18

    18 me150 - installation and operation manual 3.5 offset chimney installation table 2 – the minimum system height when using elbows fireplace model me150 wood fireplace chimney model olympia chimney vertical installation 15 ft. (4.5 m) two (2) elbows 15 ft. (4.5 m) four (4) elbows 17 ft. (5.2 m) afte...

  • Page 19

    Me150 - installation and operation manual 19 a insulated wall radiation shield b gypsum board c insulated wall 3.7 chimney support installation universal roof support this support has three possible uses: 1. It must be used on a roof to support the chimney. 2. It may be used on a floor, ceiling or r...

  • Page 20: Fireplace Finish

    20 me150 - installation and operation manual 4 fireplace finish 1. Combustible materials can be used to finish the fireplace. The framing can be built directly on the sides of the appliance. 2. Side walls can exceed the appliance’s face by a maximum of 6" (152 mm). 3. Adjoining walls may also be bui...

  • Page 21

    Me150 - installation and operation manual 21 chimney enclosure canada and u.S. Chimney enclosure canada only..

  • Page 22

    22 me150 - installation and operation manual mantel position mantel lenght min. Distance from fireplace bottom 6" / 152 mm 48" / 1219 mm 8" / 203 mm 50" / 1270 mm 10" / 254 mm 52" / 1321 mm 12" / 305 mm 54" / 1372 mm 48” 1219 mm.

  • Page 23

    Me150 - installation and operation manual 23 1.1 fireplace facing 1. Remove the decorative trim. 2. Install the non-combustible facing material (marble, ceramic tile, durock, brick, etc.). 3. Reinstall the decorative trim. Note: make sure nothing obstructs or interferes with the front hot air outlet...

  • Page 24

    24 me150 - installation and operation manual.

  • Page 25: Use And Safety

    Me150 - installation and operation manual 25 5 use and safety 1. Teach children fireplace safety rules. 2. Do not use the fireplace under the following conditions: 1. Whenever a firestone is missing or broken. 2. Whenever the ceramic glass is cracked or broken. 3. Never use flammable liquids to ligh...

  • Page 26

    26 me150 - installation and operation manual 5.1 manufactured logs do not burn manufactured logs made of wax impregnated sawdust or logs with any chemical additives. Manufactured logs made of 100% compressed sawdust can be burned, but use caution in the number of these logs burned at one time. Start...

  • Page 27: Maintenance

    Me150 - installation and operation manual 27 6 maintenance 1. Clean color trim with soapy water and a soft cloth. Do not use any metal polish or abrasives. 2. Keep the glass relatively clean. Dirty windows will make the fireplace overheat. Wait until the glass is cool before attempting to clean it. ...

  • Page 28

    28 me150 - installation and operation manual pl60004.

  • Page 29: Troubleshooting

    Me150 - installation and operation manual 29 7 troubleshooting expansion and contraction noises during the heating and cooling cycle are normal. Here is how to prevent smoke flow reversal: position air intake lever to maximum, slowly open the fireplace doors before lighting the kindling, make a torc...

  • Page 30

    30 me150 - installation and operation manual 7.1 exploded view for replacement parts.

  • Page 31

    Me150 - installation and operation manual 31 7.2 parts list # item description qty 1 se60079 bottom or top louver assembly 2 2 30472 spring 1/2'' outside dia. X 3''l 4 3 pl59815 exhaust damper rod 1 4 se60063 exhaust damper assembly 1 5 30484 wing nut 1/4-20 2 6 pl59765 4'' adapter for fresh air int...

  • Page 32

    32 me150 - installation and operation manual ventis limited lifetime warranty the warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This warranty covers brand new products only, which have not been altered, modified nor repaired since shipment from f...