Venus GREEN PLUS 630-730-700-850-1000-850D Instructions For Installation And Use Manual - page 11
INSTRUCTION FOR INSTALLATION AND USE - VENUS - WOOD
MONTAGE- UND BEDIENUNGSANLEITUNG - VENUS - HOLTZ
M-DESIGN
11
2.7.1 MINIMUM HEIGHT OF THE FLUE IN TERMS OF ITS REDUCTION.
MINIMUM HÖHE SCHORNSTEINKANAL MIT ANDEREM DURCHMESSER
ø 250
ø 200
ø 180
Venus 700
≥ 4m
Venus 850
≥ 4m
≥ 6m
Venus 1000
≥ 4m
≥ 6m
Venus 630
≥ 4m
≥ 6m
Venus 730
≥ 4m
≥ 6m
Venus 850 D
≥ 4m
≥ 6m
2.7 THE FLUE
The standard diameter of the Venus exhaust is:
VENUS 1000 Ø 250
VENUS 850 Ø 200
VENUS 700
Ø 180
VENUS 630
Ø 200
VENUS 730
Ø 250
VENUS 850D Ø 200
The construction of chimney must comply with strict conditions:
• The flue must be thermally insulated.
The opening into the flue and its position are very important.
• One individual flue does not have more than two changes of direction.
The angle of the corner of these changes of direction may not be greater than 45
° with the perpendicular.
• The existing obstacles in the vicinity of the opening into the flue must be taken
into account.
2.7 SCHORNSTEIN
Der Durchmesser der Abgasstutzen der Venusgeräte beträgt:
VENUS 1000 Ø 250
VENUS 850 Ø 200
VENUS 700
Ø 180
VENUS 630
Ø 200
VENUS 730
Ø 250
VENUS 850D Ø 200
Die Vorgaben für den Bau des Schornsteinkanals müssen unbedingt
beachtet werden.
•Der Winkel der Richtungsänderungen mit der Senkrechten darf nicht
größer sein als 45°.
•Der Ausgang des Schornsteins sowie die Ortsbestimmung sind sehr
wichtig.
•Ein individueller Schronstein hat maximal 2 Richtungsänderungen.
•Eventuell vorhandene Hindernisse im Bereich des Schornsteins sollten
beachtet werden.
•Schließen Sie nur ein Gerät pro Schornsteinkanal an, (Mehrfachbelegung
nur nach Absprache mit dem zuständigen Schornsteinfegermeister)