VOKERA Eclipse ESC User Instructions - page 4
4
When there is a demand for heating via the
timeclock, the boiler will go through an ignition
sequence, whereby the burner will light.
If the appliance fails to ignite during the ignition
sequence, it will re-attempt ignition several times
before going to a lockout condition. Should this
occur, please allow a period of two minutes
before re-setting.
When the appliance reaches the set temperature,
the burner will go off for minimum period of
approximately 3 minutes.
When the programmer/time clock or external
thermostats heating request has been satisfied,
the appliance will switch off automatically.
2.4
ADJUSTING THE OPERATING PARAMETERS
(see fig. 1 & 1A)
Usually your installer will have adjusted the
operating parameters to suit your requirements,
however should you wish to alter the operating
parameters, please use the following procedure:
●
press the MODE button repeatedly until you
see a fixed decimal point in LED 1;
●
press the STEP button repeatedly until the parameter
that is to be adjusted is shown in LED 1;
●
use the adjustment buttons (+/-) to alter the
current setting as shown in LED 2;
●
press the STORE button to store the new
setting into the memory;
●
press the MODE button repeatedly until no
decimal point is shown in LED 1.
To change the hot water outlet temperature
(variable between 40 - 65
°
C) press STEP button
until LED 1 shows 1.
Use the adjustment buttons (=/-) to alter the current
value to the new value.
Press the STORE button to save the new value.
Press the MODE button until no decimal point is shown
in LED 1.
To change the pre-heat temperature drop (02 =
5
°
C, 03 = 10
°
C, 04 = 20
°
C, 05 = 30
°
C) press the STEP
button until LED 1 shows 2.
Use the adjustment buttons (=/-) to alter the current
value to the new value.
Press the STORE button to save the new value.
Press the MODE button until no decimal point is shown
in LED 1.
To switch the central heating ON or OFF (00 = OFF, 01
= ON) press the STEP button until LED 1 shows 3.
Use the adjustment buttons (=/-) to alter the current
value to the new value.
Press the STORE button to save the new value.
Press the MODE button until no decimal point is shown
in LED 1.
To change the central heating flow temperature
(variable between 20
°
C and 90
°
C) press the STEP
button until LED 1 shows 4.
Use the adjustment buttons (=/-) to alter the current
value to the new value.
Press the STORE button to save the new value.
Press the MODE button until no decimal point is shown
in LED 1.
PRESS MODE BUTTON UNTIL A FIXED DECIMAL POINT IS SHOWN IN LED 1
Fig. 1A