VOKERA Eclipse ESC User Instructions - page 5
5
LED 2 shows heating flow
temperature
LED 2 shows heating return
temperature
LED 2 shows cold water inlet
temperature
LED 2 shows set
temperature for heating or
hot water
(depending on current mode
of operation)
2.5
VIEWING THE OPERATING PARAMETERS
Press MODE button until a flashing decimal point
is shown in LED 1.
Press STEP until LED 1
shows 1
Press STEP until LED 1
shows 2
Press STEP until LED 1
shows 3
Press STEP until LED 1
shows 6
HOW TO...
3.1
HOW TO TOP-UP THE SYSTEM PRESSURE (fig. 3)
The system pressure must be checked periodically
to ensure the correct operation of the boiler. The
needle on the gauge should be reading between
1 and 1.5 bar when the boiler is in an off position
and has cooled to room temperature.If the
pressure requires ‘topping-up’ use the following
instructions as a guide.
●
Locate the filling valve connections (usually
beneath the boiler).
●
Attach the filling loop to both connections.
●
Open the filling valve slowly until you hear
water entering the system.
●
Close the filling valve when the pressure gauge
(on the boiler) reads between 1 and 1.5 bar.
●
Remove the filling loop from the connections.
3.2
HOW TO RESET THE APPLIANCE
When the status light is illuminated red, the
appliance will require to be reset manually. Before
resetting the boiler ensure that the pressure
gauge is indicating the correct level. Allow a
period of two minutes to elapse before pressing
the reset button.
IMPORTANT
If the appliance requires to be reset frequently, it may
be indicative of a fault, please contact your installer or
Vokera Customer Services for further advice.
3.3
HOW TO SHUT DOWN THE SYSTEM FOR
SHORT PERIODS
The system and boiler can be shut down for short
periods by simply turning the time clock to the off
position. It is also advisable to turn off the main
water supply to the house.
3.4
HOW TO SHUT DOWN THE SYSTEM FOR
LONG PERIODS
If the house is to be left unoccupied for any length
of time – especially during the winter – the system
should be thoroughly drained of all water.
Fig. 2
The gas, water, and electricity supply to the
house should also be turned off. For more detailed
advice contact your installer.
3.5
HOW TO CARE FOR THE APPLIANCE
To clean the outer casing use only a clean damp
cloth. Do not use any scourers or abrasive
cleaners.
3.6
HOW TO REGULATE THE HOT WATER
TEMPERATURE
Usually your installer will have adjusted the hot
water output to suit your requirements, however
if you would like to adjust the outlet temperature,
please follow the instructions in section 2.4.
NOTE
If you find that the hot water temperature is still
insufficient, try reducing the flow of water through
the tap.
Fig. 3