VOLTA V-385 Instruction Manual

Manual is about: Portable power inverter

Summary of V-385

  • Page 2: Contents

    Thank you for purchasing volta power inverter. Volta power inverter is designed in accordance with industr standard . Eatures excellent performance, powerful function, reliable stability and a portable design the ideal solution outdoor ac power supply and indoor emergency supply. Features a special ...

  • Page 3

    I. Safety instruction 1. Safety precautions ● the rated power v-385 is 750w (at 800w, v-385 can work for only 3 minutes continuously.) do not use the v-385 with any equipment with the rated power of over 750w. ● do not operate the nverter in fog, rain, snow, or dusty conditions. It should be used in...

  • Page 4

    Control unit battery unit 01. Handle 17. Charging socket 02. Ac output socket (110v/60hz or 18. Charging socket cover 220v/50hz) 19. Input socket for external battery 03. Socket cover 20. Input socket for external battery 04. 21. Built-in battery output 22. External power output switch on (power on)...

  • Page 5

    (2) power indicator (06) (displays power output level) power led off green orange red red, blinking output power (lp450x) 0~35w 35w~200w 200w~350w 350w~460w >460w output power (v-385) 0~35w 35w~230w 230w~520w 520w~670w >670w (3) status indicator (07) (displays working status) status led red green wo...

  • Page 6

    Instead of using the built-in battery, an external power cable (sold separately) can be used to power the inverter with an external battery (11-15v). As some external batteries have larger capacities, the inverter can work longer than that in using the built-in battery. You can purchase external bat...

  • Page 7

    Vi. Introduction to function modes (taking v-385 as an example) do not reverse the connection on the external battery. Fuses and even cause irreparable damage to the inverter. Covered by the warranty. Do not use the inverter in or around explosive and flammable gases. Ensure that the “power input (1...

  • Page 8

    11 12 2.2 recycling time of the flash using the volta inverter (using the v-385) recycling time of the flash (1) the recycling time does not change if the flash recycles in 1 second and does not exceed 800ws similarly hereinafter). The time will increase if the flash recycles in 1 second but exceeds...

  • Page 9

    Xi. Technical data model continuous output peak power input voltage range output voltage/frequency output waveform high harmonic distortion no-load current consumption conversion efficiency low-voltage alarm low-voltage shutdown storage temperature range operating temperature range battery type nomi...