Volth S-36 Instruction Manual

Summary of S-36

  • Page 1

    S-36 1000a ac auto-range clamp meters 1000a ac auto-range clamp meters s-36 s-36 s-36 make industrial job easy with in-rush current.

  • Page 2

    I. Introduction welcome to use this product. The updated bm802a adopts high-performance mcu processor,it is great value as has high reliability,security, automatically setting range funcition,hand-held clamp meter etc.. The product has a large digital display, full range overload protection, data-ho...

  • Page 3

    3.1.5 auto negative polarity indication: displaying “-”. 3.1.6 lack of battery power: displaying “ ”. 3.1.7 auto power off after turning on the instrument and without turning the function switch or pressing any button, the instrument will automatically enter into sleep mode after 10 minutes,to save ...

  • Page 4

    3.2.4 resistance Ω overload protection: effective value 220v 3.2.5 capacitance overload protection: effective value 250v warning :there is about 20pf dead zone in the 10nf,capacitance below 20pf can not be measured 3.2.6 frequency overload protection: effective value 250v . Input sensitivity rms: ef...

  • Page 5

    3.2.8 temperature temperature sensor: k wrnm- 010 bare contact thermojunction overload protection :effective value 250v 3.2.9 forward voltage drop of diode displaying approximate forward voltage values of diode. Measuring condition: forward direct current is 1.5ma; opposite dc voltage is about 3 v. ...

  • Page 6

    4.2 measurement of ac/dc voltage turn the rotary switch to “v”. Then plug black lead in “com” socket, and plug red lead in “v/Ω” socket. Connect the test lead with the two ends of the circuit and then directly read the reading on the lcd display note : 1. The inrush measuring funciton can only be ch...

  • Page 7

    (7) connect the test lead with the two ends of the diode, and then read the value of forward voltage drop value. (8) when the test lead is under reverse connection or open-circuit status, the display will display “ol”. Note : a ) when the resistance measured is above 1mΩ, it needs several seconds fo...

  • Page 8

    (7) connect the test lead with the two ends of the diode, and then read the value of forward voltage drop value. (8) when the test lead is under reverse connection or open-circuit status, the display will display “ol”. Note : a ) when the resistance measured is above 1mΩ, it needs several seconds fo...