    35 w&t pc cards for isa bus systems subject to error and alteration manual pc cards for isa bus systems type 13001, 13401 13601, 13801 13802 release 1.3 w&t.

  • Page 2

    36 w&t pc cards for isa bus systems © 01/2008 by wiesemann & theis gmbh subject to error and alteration: since it is possible that we make mistakes, you mustn’t use any of our statements without verification. Please, inform us of any error or misunderstanding you come about, so we can identify and e...

  • Page 3

    37 w&t pc cards for isa bus systems subject to error and alteration w&t has made available an entire family of serial pc interface cards which, thanks to the integrated galvanic isolation of the ports from the pc and the ability to equip the serial ports on the card with various physical interfaces,...

  • Page 4

    38 w&t pc cards for isa bus systems index inhalt pc cardsfor isa bus systems mainboard for 2 serial interface modules, #13001 ................. 39 2x 20ma, #13401 .............................................................. 45 2x rs422/rs485, #13601 ...................................................

  • Page 5

    39 w&t pc cards for isa bus systems subject to error and alteration function the w&t serial module mainboard equip your pc with two independent serial interfaces with an insulation of up to 1000 volts. The integration of interface specific components in the form of exchangeable interface modules off...

  • Page 6

    40 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...

  • Page 7

    41 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...

  • Page 8

    42 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the serial ttl interfaces of the w&t serial module mainboard use pin header connectors with identical pin configuration. The connector pin assignments are shown in the table below: irq...

  • Page 9

    43 w&t pc cards for isa bus systems subject to error and alteration pin 1 of the pin head connector has a square pad while the other pins have round pads. Technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..115200 baud ...

  • Page 10

    44 w&t pc cards for isa bus systems.

  • Page 11

    45 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13401 equip your pc with two independent 20ma serial interfaces with an insulation of up to 1000 volts. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compatible wit...

  • Page 12

    46 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...

  • Page 13

    47 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...

  • Page 14

    48 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the two ports of the w&t 20 ma pc card 13401 use db9 male connectors with identical pin configuration. The connector pin assignments are shown in the table below: irq sw 1.1 sw 1.2 sw ...

  • Page 15

    49 w&t pc cards for isa bus systems subject to error and alteration applications the pc card 13401 can be used as an active or passive 20ma component. In the active mode, the card supplies the current required by the respective 20ma loop, while in the passive mode the loop current must be supplied b...

  • Page 16

    50 w&t pc cards for isa bus systems technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..57600 baud data format: any data format operation modes: 20ma active / passive mode independently selectable for tx and rx current ...

  • Page 17

    51 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13601 equip your pc with two independent rs422/rs485 serial interfaces with an insulation of up to 1000 volts. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compati...

  • Page 18

    52 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...

  • Page 19

    53 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...

  • Page 20

    54 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the two ports of the w&t rs422/rs485 pc card 13601 use db9 male connectors with identical pin configuration. The connec- tor pin assignments are shown in the table below: irq sw 1.1 sw...

  • Page 21

    55 w&t pc cards for isa bus systems subject to error and alteration operating mode the rs422/rs485 interface of the w&t pc card 13601 can be set for five different operating modes by dip switch setting. The selectable operating modes are briefly described here: rs422, rs485 4 wire bus master applica...

  • Page 22

    56 w&t pc cards for isa bus systems end of transmission. The rs485 receiving channel is always active in this operating mode. Rs485, 2 wire application without echo, automatic control one data channel in each direction is available.The rs485 output driver is activated automatically with each transmi...

  • Page 23

    57 w&t pc cards for isa bus systems subject to error and alteration applications rxd a (-) rxd b (+) txd a (-) txd b (+) cts a (-) cts b (+) rts a (-) rts b (+) rs422 de vice rs422 hardware handshake application data out a data out b data in a data in b handshake out a handshake out b handshake in a...

  • Page 24

    58 w&t pc cards for isa bus systems technical data operating modes: rs422 rs485 2/4 wire mode with automatic control rs485 2/4 wire mode with handshake control switchover delay: approx. 10µs from send to receive for rs485 automatic control (can be factory changed on request) base addresses: 03f8h, 0...

  • Page 25

    59 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13801 equip your pc with two independent rs232 serial interfaces. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compatible with standard rs232 interfaces, so that t...

  • Page 26

    60 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...

  • Page 27

    61 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...

  • Page 28

    62 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..115200 baud data format: any data format isolation: no isolation esd protection: ...

  • Page 29

    63 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13802 equip your pc with two independent rs232 serial interfaces with an insulation of up to 1000 volts. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compatible wi...

  • Page 30

    64 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...

  • Page 31

    65 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...

  • Page 32

    66 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the two ports of the w&t rs232 pc card 13802 use db9 male connectors with identical pin configuration. The connector pin assignments are shown in the table below: irq sw 1.1 sw 1.2 sw ...

  • Page 33

    67 w&t pc cards for isa bus systems subject to error and alteration technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..115200 baud data format: any data format isolation: min. 1000 volts esd protection: up to 15kv acco...

  • Page 34

    68 w&t pc cards for isa bus systems.