W&T Electronics SW 1.1 Manual - page 2
36
W&T
PC cards for ISA bus systems
© 01/2008 by Wiesemann & Theis GmbH
Subject to error and alteration:
Since it is possible that we make mistakes, you mustn’t use any
of our statements without verification. Please, inform us of any
error or misunderstanding you come about, so we can identify
and eliminate it as soon as possible.
Carry out your work on or with W&T products only to the
extent that they are described here and after you have comple-
tely read and understood the manual or guide. We are not liable
for unauthorized repairs or tampering. When in doubt, check
first with us or with your dealer.
Summary of SW 1.1
Page 1
35 w&t pc cards for isa bus systems subject to error and alteration manual pc cards for isa bus systems type 13001, 13401 13601, 13801 13802 release 1.3 w&t.
Page 2
36 w&t pc cards for isa bus systems © 01/2008 by wiesemann & theis gmbh subject to error and alteration: since it is possible that we make mistakes, you mustn’t use any of our statements without verification. Please, inform us of any error or misunderstanding you come about, so we can identify and e...
Page 3
37 w&t pc cards for isa bus systems subject to error and alteration w&t has made available an entire family of serial pc interface cards which, thanks to the integrated galvanic isolation of the ports from the pc and the ability to equip the serial ports on the card with various physical interfaces,...
Page 4
38 w&t pc cards for isa bus systems index inhalt pc cardsfor isa bus systems mainboard for 2 serial interface modules, #13001 ................. 39 2x 20ma, #13401 .............................................................. 45 2x rs422/rs485, #13601 ...................................................
Page 5
39 w&t pc cards for isa bus systems subject to error and alteration function the w&t serial module mainboard equip your pc with two independent serial interfaces with an insulation of up to 1000 volts. The integration of interface specific components in the form of exchangeable interface modules off...
Page 6
40 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...
Page 7
41 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...
Page 8
42 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the serial ttl interfaces of the w&t serial module mainboard use pin header connectors with identical pin configuration. The connector pin assignments are shown in the table below: irq...
Page 9
43 w&t pc cards for isa bus systems subject to error and alteration pin 1 of the pin head connector has a square pad while the other pins have round pads. Technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..115200 baud ...
Page 10
44 w&t pc cards for isa bus systems.
Page 11
45 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13401 equip your pc with two independent 20ma serial interfaces with an insulation of up to 1000 volts. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compatible wit...
Page 12
46 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...
Page 13
47 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...
Page 14
48 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the two ports of the w&t 20 ma pc card 13401 use db9 male connectors with identical pin configuration. The connector pin assignments are shown in the table below: irq sw 1.1 sw 1.2 sw ...
Page 15
49 w&t pc cards for isa bus systems subject to error and alteration applications the pc card 13401 can be used as an active or passive 20ma component. In the active mode, the card supplies the current required by the respective 20ma loop, while in the passive mode the loop current must be supplied b...
Page 16
50 w&t pc cards for isa bus systems technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..57600 baud data format: any data format operation modes: 20ma active / passive mode independently selectable for tx and rx current ...
Page 17
51 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13601 equip your pc with two independent rs422/rs485 serial interfaces with an insulation of up to 1000 volts. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compati...
Page 18
52 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...
Page 19
53 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...
Page 20
54 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the two ports of the w&t rs422/rs485 pc card 13601 use db9 male connectors with identical pin configuration. The connec- tor pin assignments are shown in the table below: irq sw 1.1 sw...
Page 21
55 w&t pc cards for isa bus systems subject to error and alteration operating mode the rs422/rs485 interface of the w&t pc card 13601 can be set for five different operating modes by dip switch setting. The selectable operating modes are briefly described here: rs422, rs485 4 wire bus master applica...
Page 22
56 w&t pc cards for isa bus systems end of transmission. The rs485 receiving channel is always active in this operating mode. Rs485, 2 wire application without echo, automatic control one data channel in each direction is available.The rs485 output driver is activated automatically with each transmi...
Page 23
57 w&t pc cards for isa bus systems subject to error and alteration applications rxd a (-) rxd b (+) txd a (-) txd b (+) cts a (-) cts b (+) rts a (-) rts b (+) rs422 de vice rs422 hardware handshake application data out a data out b data in a data in b handshake out a handshake out b handshake in a...
Page 24
58 w&t pc cards for isa bus systems technical data operating modes: rs422 rs485 2/4 wire mode with automatic control rs485 2/4 wire mode with handshake control switchover delay: approx. 10µs from send to receive for rs485 automatic control (can be factory changed on request) base addresses: 03f8h, 0...
Page 25
59 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13801 equip your pc with two independent rs232 serial interfaces. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compatible with standard rs232 interfaces, so that t...
Page 26
60 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...
Page 27
61 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...
Page 28
62 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..115200 baud data format: any data format isolation: no isolation esd protection: ...
Page 29
63 w&t pc cards for isa bus systems subject to error and alteration function the w&t pc card 13802 equip your pc with two independent rs232 serial interfaces with an insulation of up to 1000 volts. Both serial ports are equipped with type 16c550 fifo uarts; this makes them functionally compatible wi...
Page 30
64 w&t pc cards for isa bus systems configuring the card the base address and the required interrupt line can be set by dip switches at the lower edge of the card. Base addresses the i/o base addresses of the two ports can be set indepen- dently by dip switches to 03f8h, 02f8h, 03e8h or 02e8h. Seria...
Page 31
65 w&t pc cards for isa bus systems subject to error and alteration please see the following tables for an explanation of the address dip switch settings: since the address is decoded by means of gals, customizing of the i/o address is no problem. This option makes it possible to employ more than 4 ...
Page 32
66 w&t pc cards for isa bus systems interrupt setting port 1 interrupt setting port 2 connectors and pin assignment the two ports of the w&t rs232 pc card 13802 use db9 male connectors with identical pin configuration. The connector pin assignments are shown in the table below: irq sw 1.1 sw 1.2 sw ...
Page 33
67 w&t pc cards for isa bus systems subject to error and alteration technical data base addresses: 03f8h, 02f8h, 03e8h, 02e8h interrupts: irq3, irq4, irq5, irq7 irq9, irq10, irq11, irq12 baudrate: 50..115200 baud data format: any data format isolation: min. 1000 volts esd protection: up to 15kv acco...
Page 34
68 w&t pc cards for isa bus systems.