WAC Lighting MS-120 Installation Instruction
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DeCember, 2014
1
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
INSTALLATION INSTRUCTION
Motion Sensor
MS-120
WARNING
IMPORTANT: NEVER attempt any work without shutting off the electricity.
-
Read all instructions before installing.
-
System is intended for installation by a qualified electrician in accordance with the National Electrical Code and local regulations.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
-
Lisez toutes les instructions avant d’installer.
-
Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux.
INTRODUCTION
The Motion Sensor utilizes passive infrared (PIR) technology to detect heat radiation of moving bodies. Upon detection, the connected lighting
load will illuminate for a user-determined time period. An integrated daylight sensor (Photoelectric Cell) ensures operation and detection only at
night. The extension kit provides versatility in aiming the unit.
Input
: 120V AC
Max. Load
: 200W LED Lamp
Application Location
: Dry or Wet locations
FEATURES
1. Intelligent motion control of luminaires based on occupancy.
2. The double hinge structure allows users to aim the sensor in any position they want.
3. Can be mounted on a canopy or on a lighting fixture.
4. Built-in adjustable timer allows automatic shut off after the sensor coverage area is vacated.
Maximum time delay is 5 minutes, minimum is 5 seconds.
5. Designed for outdoor (wet location) or indoor application. Recommended ambient temperature is -20°C (-4°F) to 50°C (122°F).
I - Connector
L - Connector
Locking Nut
Extension Rod