INSTALLATION INSTRUCTION
Motion Sensor
MS-120
WIRING DIAGRAM
Single Sensor
Neutral (White)
Neutral (White)
Line
120VAC, 60Hz
Line
120VAC, 60Hz
Fixture
(Shown WAC WP-LED119)
Fixture
(Shown WAC WP-LED119)
White
White
Time on adjustment knob
Light level adjustment knob
Less sensitive
More sensitive
Red
W
hit
e
W
hit
e
W
hit
e
Red
Red
Sensor
Sensor
Sensor
Black
Black
Black
Black
Black
Hot (Black)
Hot (Black)
Top view
Side view
100°
180°
12m
10m
5m
2m
2.5m
Multiple Sensors
OPERATION AND TESTING
WALKING TEST:
This test allows the user to establish the detection pattern and choose the
best position for the sensor. Adjust the sensor to point in the desired direction
by rotating the unit from left to right and up to down. See the sensitivity
patterns of the sensor to achieve the desired results.
1. Set the two adjustment controls on the bottom of the sensor to the
following positions:
TIME - Fully anti-clockwise (left hand dial);
LUX - Fully clockwise (right hand dial);
2. The unit will now operate during daytime as well as at night, illuminating
the lamp for approximately 5 seconds each time. Switch on the mains
power. The lamp will immediately illuminate as the unit goes through
its “warm-up” period. After approximately 1 - 2 minutes the lamp will
extinguish. Remain outside the detection area during the warm-up
period.
3. Walk across the detection area approximately 16 feet from the unit.
As you cross a detection “zone” the lamp will illuminate.
Now stand still until the lamp extinguishes.
This should take approximately 5 seconds.
4. Start moving. As you cross each “zone” the lamp will illuminate.
Repeat the above, walking at various distances and angles to the unit.