Extension cable
Only use permitted extension cables, see chapter Safety.
Refer to the following table for the required cross-section area of the exten-
sion cable:
Note:
Refer to the nameplate or the chapter Technical data (via the item
number) for the type designation and voltage rating of your machine.
WARNING
Electrical voltage.
Injuries from electrocution.
f Check power cable and extension cable for signs of damage.
f Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data).
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
110–127 1~
< 8
1.5
< 13
2.5
< 20
4.0
< 30
6.0
220–240 1~
< 27
1.5
< 44
2.5
< 70
4.0
< 105
6.0