Waeco Bordbar CDF-11 Instruction Manual - Set

Other manuals for Bordbar CDF-11: Operating Manual, Instruction Manual

Summary of Bordbar CDF-11

  • Page 1

    Bordbar cdf-11 de 4 kompressor bordbar bedienungsanleitung en 18 compressor bordbar instruction manual _cdf-11_de_en.Book seite 1 freitag, 7. August 2009 4:11 16.

  • Page 2: Set

    Bordbar cdf-11 2 emergency override normal use 1 11 10 9 2 3 4 5 6 7 8 12 1 power fridge freezer error set 1 2 3 4 5 6 7 2 _cdf-11_de_en.Book seite 2 freitag, 7. August 2009 4:11 16.

  • Page 3

    Bordbar cdf-11 3 1 2 3 4 5 6 3 _cdf-11_de_en.Book seite 3 freitag, 7. August 2009 4:11 16.

  • Page 4: Contents

    Bordbar cdf-11 safety instructions 18 please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is resold, this operating manual must be handed over to the purchaser along with it. Contents 1 safety instructions . . . . . . . ...

  • Page 5: 1.2

    Safety instructions bordbar cdf-11 19 z the cooling device is not suitable for transporting caustic materials or materials containing solvents. Z do not open the refrigerant circuit under any circumstances! E z connect the device with the 12/24 v lead supplied to a 12/24 v socket. Z do not pull the ...

  • Page 6: Intended Use

    Bordbar cdf-11 intended use 20 z a few water drops may form inside the cooler if it has been cool- ing for a lengthy period. This is normal because the moisture in the air condenses to water when the temperature in the cooler falls. The cooler is not defective. Wipe it out with a dry cloth if necess...

  • Page 7: Technical Description

    Technical description bordbar cdf-11 21 4 technical description the cooler can chill products, keep them cool as well as freeze them. A main- tenance-free, cfc-free refrigerant circuit with compressor provides the cool- ing. The cooler is suitable for mobile use. When used in vehicles the cooler can...

  • Page 8: 4.2

    Bordbar cdf-11 technical description 22 4.2 operating and display elements control panel (fig. 2, page 2) item description explanation 1 on/off button switches the cooler on or off when the button is pressed for between one and two seconds 2 power status indication led lights up green compressor is ...

  • Page 9: Operation

    Operation bordbar cdf-11 23 5 operation the device is equipped with an interior led light which remains on whenever power is connected. The power consumption of this led light is extremely low and insignificant compared to the overall power consumption of the device. 5.1 before initial use i note be...

  • Page 10: 5.5

    Bordbar cdf-11 operation 24 5.5 securing the cooler in the vehicle ➤ open the lid of the cooler. ➤ place the seat belt into the fixing position (fig. 1 3, page 2) of the cooler. ➤ close the lid. ➤ fasten the seat belt and tighten it. 5.6 switching-on the cooler e caution – danger of overheating! Ens...

  • Page 11: 5.7

    Operation bordbar cdf-11 25 ➤ press the “on/off” button (fig. 2 1, page 2) for three seconds. ✓ the “power” led (fig. 2 2, page 2) lights up green. When the cooler reaches the preset temperature, the led lights up orange. ✓ the display (fig. 2 5, page 2) switches on and shows the current cooling tem...

  • Page 12

    Bordbar cdf-11 operation 26 i note when switched off by the battery monitor due to low voltage the display (fig. 2 5, page 2) goes blank and the “power” led (fig. 2 2, page 2) flashes orange. A caution – danger of damage! When switched off by the battery monitor, the battery will no longer be fully ...

  • Page 13: 5.10

    Operation bordbar cdf-11 27 5.10 using the emergency switch the device is equipped with an emergency switch. Thus you can keep cool- ing if an error occurs within the interior electronics. I note during normal operation the emergency switch (fig. 1 12, page 2) has to be set to the “normal” position....

  • Page 14: 5.13

    Bordbar cdf-11 cleaning and maintenance 28 5.13 replacing the plug fuse (12/24 v) ➤ pull the adapter sleeve (fig. 3 4, page 3) off of the plug. ➤ unscrew the screw (fig. 3 5, page 3) out of the upper half of the housing (fig. 3 6, page 3). ➤ carefully raise the upper half of the housing from the low...

  • Page 15: Troubleshooting

    Troubleshooting bordbar cdf-11 29 7 troubleshooting 8 disposal ➤ place the packaging material in the appropriate recycling waste bins wherever possible. M if you wish to finally dispose of the device, ask your local recycling centre or specialist dealer for details about how to do this in accordance...

  • Page 16: Technical Data

    Bordbar cdf-11 technical data 30 9 technical data i note at ambient temperatures above 32 °c (90 °f) the minimum temperature cannot be achieved. The coolant circuit contains r134a. Versions, technical modifications and delivery options reserved. Bordbar cdf-11 item no.: 9105100007 gross capacity: 10...

  • Page 17

    _cdf-11_de_en.Book seite 31 freitag, 7. August 2009 4:11 16.

  • Page 18: Www.Waeco.Com

    Europe a dometic austria gmbh neudorferstrasse 108 2353 guntramsdorf ℡ +43 2236 908070 +43 2236 90807060 mail: info@waeco.At h dometic switzerland ag riedackerstrasse 7a ch-8153 rümlang (zürich) ℡ +41 44 8187171 +41 44 8187191 mail: info@waeco.Ch l dometic denmark a/s nordensvej 15, taulov dk-7000 f...