    Coolfreeze cfx28, cfx35, cfx40, cfx50, cfx65, cfx65dz cfx 28 cfx 35 cfx 40 cfx 50 cfx 65, cfx 65 dz compressor cooler instruction manual.

  • Page 3: Contents

    En cfx28 – cfx65dz 3 please read this operating manual carefully before starting the device. Keep it in a safe place for future reference. If the device is passed on to another person, this operating manual must be handed over to the user along with it. The manufacturer cannot be held liable for dam...

  • Page 4: Explanation of Symbols

    En explanation of symbols cfx28 – cfx65dz 4 11 disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 12 technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 1 explanation of symbols d ! ! A i ➤ action: this ...

  • Page 5: Safety Instructions

    En cfx28 – cfx65dz safety instructions 5 2 safety instructions 2.1 general safety d danger! On boats: if the appliance is powered by the mains, ensure that the power supply has a residual current circuit breaker. ! Warning! Do not operate the device if it is visibly damaged. If this device's power c...

  • Page 6: 2.2

    En safety instructions cfx28 – cfx65dz 6 a notice! Check that the voltage specification on the type plate corresponds to that of the energy supply. Only connect the device as follows: – with the dc cable to a dc plug socket in the vehicle (e. G. Cigarette lighter) – or with the 230 v connection cabl...

  • Page 7: Scope of Delivery

    En cfx28 – cfx65dz scope of delivery 7 do not fill the inner container with ice or fluid. Never immerse the device in water. Protect the device and the cable against heat and moisture. 3 scope of delivery item quantity description 1 1 cooler 2 1 connection cable for 12/24 vg connection 3 1 connectio...

  • Page 8: Accessories

    En accessories cfx28 – cfx65dz 8 4 accessories available as accessory (not included in scope of delivery): 5 intended use the cooler is suitable for cooling and freezing foods. The device is also suitable for use on boats. The device is designed to be operated from a 12 v g or 24 v g on- board suppl...

  • Page 9: Function Description

    En cfx28 – cfx65dz function description 9 6 function description the cooler can chill products, keep them cool as well as freeze them. A low maintenance refrigerant circuit with compressor provides the cooling. The generous insulation and powerful compressor ensure efficient and fast cooling. The co...

  • Page 10: –

    En function description cfx28 – cfx65dz 10 operating panel item description explanation 1 on off switches the cooler on or off when the button is pressed for between one and two seconds 2 power “p ” status indication led lights up green: compressor is on led lights up orange: compressor is off led f...

  • Page 11

    En cfx28 – cfx65dz function description 11 connection sockets emergency switch (when fitted) and usb port item description 1 connection socket ac voltage supply 2 fuse holder 3 connection socket dc voltage supply item description 1 emergency switch 2 usb port for power supply 100-240v~ac 12/24v dc 1...

  • Page 12: Operation

    En operation cfx28 – cfx65dz 12 7 operation 7.1 before initial use i reversing the lid opening direction cfx50, cfx65, cfx65dz the lid hinges can be moved to the opposite side if you want to open the lid from the opposite direction. To do this, proceed as follows: ➤ open the lid and remove it (a). ➤...

  • Page 13: 7.2

    En cfx28 – cfx65dz operation 13 selecting the temperature units temperature display units can be switched between celsius and fahrenheit as follows: ➤ switch on the cooler. ➤ press the “set” button (fig. 3 4, page 10) twice. ➤ use the “up +” (fig. 3 7, page 10) or “down –” (fig. 3 6, page 10) button...

  • Page 14: 7.3

    En operation cfx28 – cfx65dz 14 7.3 connecting the cooler connecting to a battery (vehicle or boat) the cooler can be operated with 12 v or 24 v g . A for safety reasons the cooler is equipped with an electronic system to prevent the polarity reversal. This protects the cooler against short-circuiti...

  • Page 15: 7.4

    En cfx28 – cfx65dz operation 15 7.4 using the battery monitor the device is equipped with a multi-level battery monitor that protects your vehicle battery against excessive discharging when the device is connected to the on-board 12/24 v supply. If the cooler is operated when the vehicle ignition is...

  • Page 16

    En operation cfx28 – cfx65dz 16 the battery monitor mode can be selected as follows: ➤ switch on the cooler. ➤ press the “set” button (fig. 3 4, page 10) three times. ➤ use the “up +” (fig. 3 7, page 10) or “down –” (fig. 3 6, page 10) buttons to select the battery monitor mode. ✓ digital display wi...

  • Page 17: 7.5

    En cfx28 – cfx65dz operation 17 7.5 using the cooler a cfx28, cfx35, cfx40, cfx50, cfx65 i notice! Danger of overheating! Ensure at all times that there is sufficient ventilation so that the heat that generated during operation can dissipate. Ensure that the ventilation slots are not covered. Make s...

  • Page 18

    En operation cfx28 – cfx65dz 18 cfx65dz ! I cfx28, cfx35, cfx40, cfx50, cfx65, cfx65dz ➤ place the cooler on a firm foundation. Make sure that the ventilation slots are not covered and that the heated air can dissipate. I ➤ connect the cooler, see chapter “connecting the cooler” on page 14. Caution!...

  • Page 19: 7.6

    En cfx28 – cfx65dz operation 19 a ➤ press the “on/off” button (fig. 3 1, page 10) for between one and two seconds. ✓ the led “p” lights up (fig. 3 2, page 10). ✓ the display (fig. 3 5, page 10) switches on and shows the current cool- ing temperature. ✓ the cooler starts cooling the interior. I latch...

  • Page 20: 7.7

    En operation cfx28 – cfx65dz 20 7.7 using the emergency switch (where fitted) the emergency switch (fig. 5 1, page 11) is located below the control panel on all models except cfx28 where it is located above the power inlet sockets. For normal operation the switch is in the “normal use” position. ➤ i...

  • Page 21: 7.10

    En cfx28 – cfx65dz operation 21 7.10 defrosting the cooler humidity can form frost in the interior of the cooling device or on the evaporator. This reduces the cooling capacity. Defrost the device in good time to avoid this. A to defrost the cooler, proceed as follows: ➤ take out the contents of the...

  • Page 22: 7.12

    En operation cfx28 – cfx65dz 22 7.12 replacing the plug fuse (12/24 v) ➤ pull the adapter sleeve (4) off of the plug. ➤ unscrew the screw (5) out of the upper half of the housing (6). ➤ carefully lift the upper half of the housing off from the lower (1) half. ➤ take out the contact pin (3). ➤ replac...

  • Page 23: 7.13

    En cfx28 – cfx65dz operation 23 7.13 replacing the light pcb ➤ disconnect the power supply to the device. ➤ pry out the transparent cover with a screwdriver (1). ➤ unscrew the pcb mounting screws (2). ➤ pull out the plug from the pcb (3). ➤ replace the defective light pcb with a new one. ➤ fit new p...

  • Page 24: Cleaning and Maintenance

    En cleaning and maintenance cfx28 – cfx65dz 24 8 cleaning and maintenance ! A ➤ occasionally clean the device interior and exterior with a damp cloth. ➤ make sure that the air inlet and outlet vents on the device are free of any dust and dirt, so that heat can be released and the device is not damag...

  • Page 25: Troubleshooting

    En cfx28 – cfx65dz troubleshooting 25 10 troubleshooting fault possible cause suggested remedy device does not func- tion, led does not glow. There is no voltage present in the 12/24 v socket (cigarette lighter) in your vehicle. The ignition must be switched on in most vehicles to apply current to t...

  • Page 26: Disposal

    En disposal cfx28 – cfx65dz 26 11 disposal ➤ place the packaging material in the appropriate recycling waste bins wherever possible. M if you wish to finally dispose of the product, ask your local recycling centre or specialist dealer for details about how to do this in accordance with the applicabl...

  • Page 27

    En cfx28 – cfx65dz technical data 27 i test/certificates: the coolant circuit contains r134a. Cfx50 cfx65 cfx65dz item no. 9105303572 9105303573 9105303574 connection voltage: 12/24 v g and 100–240 v w rated current: 12 v g : 7.8 a 24 vg: 3.6 a 100 v w : 0.95 a 240 v w : 0.46 a 12 v g : 8.2 a 24 vg:...

  • Page 28: Www.Waeco.Com.Au

    Austria dometic austria gmbh neudorferstrasse 108 2353 guntramsdorf +43 2236 908070 +43 2236 90807060 mail: info@waeco.At benelux dometic benelux b.V. Ecustraat 3 nl-4879 np etten-leur +31 76 5029000 +31 76 5029090 mail: info@dometic.Nl denmark dometic denmark a/s nordensvej 15, taulov dk-7000 frede...