WAGNER SUNGO S Operating Instructions Manual

Manual is about: Solar Controller

Summary of SUNGO S

  • Page 1

    Operating instructions, issue sw1201/ 2.01/ hw2.4 wagner & co solar controller sungo s wagner & co contents 1. Technical description . . . . . . . . . . . . . . . . . . 2 2. General safety guidelines . . . . . . . . . . . . . . . 4 2.1 installer’s qualifications . . . . . . . . . . . . . . . . . 4 2...

  • Page 2

    2 en-sungo-s_ba-0804-1122p200 1. Technical description solar controller sungo s material 100 % recyclable abs casing for wall mounting dimensions (l x h x w in mm) 173 x 138 x 51 protection type ip40 according to vde 0470 rate of radio interference n according to vde 0875 mains supply 230 volt ac; 5...

  • Page 3

    En-sungo-s_ba-0804-1122p200 3 thyristors switch through the positive or negative sine half- wave as long as a switch-on difference exists. The triac switch switches off when the temperature falls below the switch-off difference. System protection in order to protect system components like solar circ...

  • Page 4

    4 en-sungo-s_ba-0804-1122p200 2. General safety guidelines the following safety advice is designed to protect you from dangers that can arise from improper handling of devices, whether intentional or otherwise. A distinction is made be- tween general advice presented here and specific advice present...

  • Page 5

    En-sungo-s_ba-0804-1122p200 5 installation in the solar circulation unit ● affix the sungo s with the appropriate screws to the wall mounting bracket of the solar circulation unit. ● open up the cable ducts next to the centre crosspiece in the bottom of the control. ● remove outer insulation of the ...

  • Page 6: Dt Min Max Start Stop

    6 en-sungo-s_ba-0804-1122p200 4. Operation 4.1 display and buttons ! Dt min max start stop r h r ok? 88888 °c % x manual operation menu special functions menu balance or start / stop values units tank temperature, upper half confirm / save icon system error settings menu information menu temperature...

  • Page 7

    En-sungo-s_ba-0804-1122p200 7 horizontal operating level vertical operating level set values settings menu as an example temperature limitation tank, bottom switch-on difference t1-t2, solar switch-off difference t1-t2, solar minimum temperature source set point temperature difference, speed control...

  • Page 8

    8 en-sungo-s_ba-0804-1122p200 4.2 information menu information menu menu item description display collector temperature; current value °c collector temperature; balance value; minimum, resettable °c collector temperature; balance value; maximum, resettable °c tank temperature, lower half; current va...

  • Page 9

    En-sungo-s_ba-0804-1122p200 9 4.4 manual operation menu manual operation menu menu item description range base value off = 0/on = 1 manual on/off via output a1 (solar circulation pump) 0 - 1 0 activation of manual operation lag time in automatic mode 0 - 600 min 0 min 4.5 special functions menu with...

  • Page 10

    10 en-sungo-s_ba-0804-1122p200 4.6 service – system messages display of system information display description correction system messages all system messages are displayed with a blinking caution symbol. In case of sensor errors the sensor in question is also marked with short circuit or interruptio...

  • Page 11

    En-sungo-s_ba-0804-1122p200 11 5. Application examples 5.1 standard single-tank system figure 4 standard single-tank system controlled by sungo s. P3 p2 ta a1 t2 t3 t1 circ o t2 ecoplus ttw t3 p1 t1 bwm hot water cold water oil or gas boiler heating circuit collector field t1: collector sensor t2: t...

  • Page 12

    Figure 5 secusol system controlled by sungo s. 5.2 secusol system t3 a1 t2 t1 secusol ta p3 p2 bwm t1 t2 t3 ttw p1 hot water cold water heating circuit collector field (euro c22) oil or gas boiler t1: collector sensor t2: tank sensor, lower half t3: tank 1 sensor, upper half (optional) p1: solar cir...