Waldorf 800 Series RN8910GE Installation And Operation Manual - page 28
26
Gas Conversion and Specifications
- All Other Markets:
NOTE:
(*) Measure Burner operating pressure at manifold test point with two burners operating at
'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to information in this section for further details.
Natural Gas
Town Gas (**)
Open Burner
Main Burner
Ø 2.45mm
Ø 4.50mm
Pilot Burner ('PF' Option Only)
0.30 0.60
Supply Pressure
1.13 - 3-4 kPa
0.75 - 1.50 kPa
Burner Operating Pressure (*)
0.95 kPa
0.63 kPa
Gas Regulator Cap Screw
Adjustable Regulator
(Adjust to Burner Operating
Pressure specified).
LP Gas (Propane)
Butane
Open Burner
Main Burner
Ø 1.50mm
Ø 1.40mm
Pilot Burner ('PF' Option Only)
0.20 0.20
Supply Pressure
2.75 - 4.50 kPa
Burner Operating Pressure (*)
2.6 kPa
Gas Regulator Cap Screw