Waldorf Fast-Fri FNB8120G Installation And Operation Manual - page 26
Manual is about: Fast-Fri Gas Fryer 800 Series
of
29
24
Gas Conversion and Specifications
Gas Specifications
NOTE:
*
Measure burner operating pressure at Operating Pressure Test Point (Lower - Out) on gas
control valve , this is to be carried out with all burners operating at the 'High Flame' setting.
Refer to ‘Gas Conversion and Specification’ Section for further details.
Natural Gas (G20)
LP Gas (Propane) (G31)
Main Burner Injectors
Ø 3.10mm
Ø 1.90mm
Pilot Burner Injectors
Non-CE
0.62
0.35
CE Only
0.45
0.30
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure
0.98 kPa (*)
(9.8 mbar)
2.50 kPa (*)
(25 mbar)
Supply Pressure
Non-CE
1.13 - 2.0 kPa
2.75 - 3.0 kPa
CE Only
20 mbar
37 mbar
Pilot Screw Adjustment