Waldorf FNB8120GE Installation And Operation Manual - page 35
33
Gas Conversion and Specifications
Gas Specifications
- Australia
- New Zealand:
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
NOTE:
*
M
easure burner operating pressure at Operating Pressure Test Point (Lower - Out) on gas
control valve with both burners operating at 'High Flame' setting. Refer to ‘Gas Conversion
and Specification’ Section for further details.
Natural Gas (G20)
Propane (G31)
Main Burner Injectors
Ø 3.10mm
Ø 1.90mm
Pilot Burner Injectors
0.45 0.30
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure (*)
0.98 kPa
2.50 kPa
Supply Pressure
20 mbar
37 mbar
Natural Gas
LP Gas (Propane)
Main Burner Injectors
Ø 3.10mm
Ø 1.90mm
Pilot Burner Injectors
0.62 0.35
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure (*)
0.98 kPa
2.50 kPa
Supply Pressure
1.13 - 2.0 kPa
2.75 - 3.0 kPa
Natural Gas
LP Gas
Main Burner Injectors
Ø 3.10mm
Ø 1.90mm
Pilot Burner Injectors
0.62 0.35
Pilot Screw Adjustment
Full Out (CCW)
1½ turns out (CCW)
Burner Operating Pressure (*)
0.98 kPa
2.50 kPa
Supply Pressure
1.13 - 2.0 kPa
2.75 - 3.0 kPa