Waldorf FNB8120GE Installation And Operation Manual - page 7
5
Specifications
- All Other Markets:
NOTE:
(*) M
easure burner operating pressure at Lower Test Point (Out) on the gas control
valve, with both burners operating at 'High Flame' setting.
(**) TOWN GAS Option is only available with specific ex-factory built Town Gas
models, which can also be converted to any other gas. Standard models can only be
converted between Nat. Gas, LP Gas and Butane, but not Town Gas.
Refer to ‘Gas Conversion and Specifications' section of this manual for further details.
Electrical Supply Requirements
220 -240Vac, 1P+N+E, 50Hz, 0.5A.
Electrical Connection
The power cord comes fitted with:
Australia / NZ models -
10A 3-pin plug.
United Kingdom models -
13A 3-pin fused plug.
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.
Warning
Natural Gas
Town Gas (**)
Input Rating (N.H.G.C.)
90 MJ/hr
90 MJ/hr
Supply Pressure
Non-CE
1.13 - 2.0 kPa
0.75 - 1.5 kPa
CE
25 mbar
N/A
Burner Operating Pressure (*)
0.98 kPa (*)
0.5 kPa (*)
Gas Connection
¾” BSP Male
LP Gas (Propane)
Butane
Input Rating (N.H.G.C.)
90 MJ/hr
90 MJ/hr
Supply Pressure
Non-CE
2.75 - 3.0 kPa
2.75 - 3.0 kPa
CE
37 mbar
37 mbar
Burner Operating Pressure (*)
2.5 kPa (*)
2.5 kPa (*)
Gas Connection
¾” BSP Male