Waldorf RN8410G Installation And Operation Manual - page 10
8
Clearances
NOTE: Only non-combustible materials can be used in close proximity to this appliance.
* Side clearances can be 50 mm when the adjacent surface is at least 100 mm below the cooking
surface.
Assembly
NOTE:
• All Models are delivered completely assembled. No further assembly is required.
• This appliance is fitted with adjustable feet to enable the appliance to be positioned
securely and level. This should be carried out on completion of the gas connection. Refer
to the ‘Gas Connection’ section.
Optional Accessories (Refer to Replacement Parts List)
• Rear Roller Kit. For installation details, refer to the instructions supplied with each kit.
• Plinth Kit. For installation details, refer to the instructions supplied with each kit.
1.
Check that all the feet (or castors) are securely fitted.
2.
Adjust the four feet to make the convection oven range steady and level.
Gas Connection
NOTE: ALL GAS FITTING MUST ONLY BE CARRIED OUT BY AN AUTHORISED PERSON.
1.
Waldorf Ranges do not require an electrical connection, as they function totally on the gas supply
only.
2.
It is essential that the gas supply is correct for the appliance to be installed and that adequate
supply pressure and volume are available. The following checks should therefore be made before
installation:-
a. Gas Type the appliance has been supplied for is shown
on coloured stickers located above the gas connection
and next to the rating plate. Check that this is correct
for the gas supply the appliance is being installed for.
The gas conversion procedure is detailed in this manual.
b. Supply Pressure required for this appliance is shown in
the ‘Specifications’ section of this manual. Check the gas
supply to ensure adequate supply pressure exists.
c. Input Rate of this appliance is stated on the Rating Plate
and in the ‘Specifications’ section of this manual. The
input rate should be checked against the available gas
supply line capacity. Particular note should be taken
if the appliance is being added to an existing
installation.
NOTE: It is important that adequately sized piping runs directly to the connection joint on the
appliance with as few tees and elbows as possible to give maximum supply volume.
3.
Fit the gas regulator supplied, into the gas supply line as close to the appliance as possible.
Installation
Combustible Surface
Non Combustible Surface
Left/Right hand side
250 mm (*)
0 mm
Rear
100 mm
0 mm
Fig 1
Rating Plate
Location