Waldorf RN8510GC Installation And Operation Manual - page 6
Specifications
4
Gas Supply Requirements
- Australia:
- New Zealand:
- UK Only:
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
*
Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set through the appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas
Conversion’ section for details).
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Griddle
(each 300mm section)
Oven Open
Burner
(each)
Griddle
(each 300mm section)
Oven
Heat Input
(nett)
Nominal
6.5 kW
5.5 kW
7.8 kW
6.5 kW
5.5 kW
7.8 kW
Reduced
1.75 kW
1.85 kW
---
1.75 kW
1.95 kW
---
Gas Rate
(nett)
Nominal
0.69 m
3
/hr 0.58
m
3
/hr 0.83
m
3
/hr
0.51 kg/hr
0.43 kg/hr
0.61 kg/hr
Reduced
0.19 m
3
/hr 0.20
m
3
/hr
---
0.14 kg/hr
0.15 kg/hr
---
Supply Pressure
20 mbar
37 mbar
Burner Operating
Pressure (*)
9.5 mbar
26 mbar
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas
LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
21 MJ/hr
- Oven
30 MJ/hr
30 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas
LP Gas
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
28 MJ/hr
- each 300mm Griddle Section
21 MJ/hr
21 MJ/hr
- Oven
30 MJ/hr
30 MJ/hr
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Burner Operating Pressure (*)
0.95 kPa
2.6 kPa
Gas Connection
3
/
4
” B.S.P. Male