    1 49634 010594 wap sc 702 wap sc 720 wap sc 730 operating instructions.

  • Page 2: Your Wap Sc.

    2 your wap sc. Congratulations on your purchase of a hot-water high-pressure cleaner of the sc generation. Do not use the unit without reading these operating instructions: • you will find all necessary information here. • you will become familiar with the technical details. • you will learn how to ...

  • Page 3

    3 © wap reinigungssysteme printed in germany contents 1 description ........................................................................................................................................ 4 1.1 general information ........................................................................

  • Page 4

    4 unsuitable cleaning agents lead to poor cleaning results and cause damage to the unit. Pre-dilute concentrate as described. Contain no. Pure or pre-dilut ph value in 1 % solution approx. Wapclean car shampoo intensive-action concentrate against dust, soot, grease, oil and insect residues. For deli...

  • Page 5

    5 1 2 3 4 5 6 7 8 9 10 11 13 12 3 5 4 1 2 1.3 unit design 4 rotating direction monitor g (sc 730 only) 5 calcification alarm g g this symbol means: not available on all models (special equipment, model versions). 1 power cable 2 tap water supply connection 3 swivel castor with locking brake 4 cleani...

  • Page 6

    6 1.4 technical data sc 702 sc 702 sc 702 sc 702 sc 720 sc 720 sc 720 sc 720 sc 730 sc 730 sc 730 sc 730 volume flow l/min 8,3-5,8 9,2-4,7 10,2-4,7 working pressure bar 105-50 130-25 140-25 permissible gauge pressure bar 200 200 200 permissible temperature °c 80/99 80/140 75/140 max. Supply temperat...

  • Page 7

    7 mode of operation of the safety equipment: the safety control block returns impermissibly high gauge pressure to the suction line of the pump via a bypass line without residual pressure. The safety valve is responsible for preventing impermissibly high gauge pressure. When actuated, the exiting li...

  • Page 8

    8 when setting up in rooms, the local building regulations for channelling exhaust gas into the open must be observed. Provide sufficient ventilation. The machine must be constantly supervised so that the operating personnel is able to notice if the flame goes out. Caution! If the machine runs dry, ...

  • Page 9

    9 el heating oil or diesel oil din 51 603 2.2 before initial start-up 2.2.1 machine secure machine with locking brake. Check oil level of high- pressure pump cut off pin on oil plug. Fill cleaning-agent tank with pre-diluted wap cleaning agent. Fill fuel tank with fuel (el heating oil or diesel oil ...

  • Page 10

    1 0 v a r i o p r e s s thumbwheel 2.2.3 electrical connection check the mains voltage of the machine before connecting it to the power supply. Make sure that the voltage indicated on the rating plate agrees with the local mains voltage. Only connect the machine with an approved plug. In the case of...

  • Page 11

    1 1 add „wap antikalk“ anti-calcification concentrate (no. 8466)! Fuel shortage! G motor is rotating in wrong direction - have electrical socket connected by an electrician in accordance with local standards ! G 2.3.3 using superclean hl-i nozzle 1. Simply turn superclean hl-i nozzle to adjust from ...

  • Page 12

    1 2 2.4 shut-down h set metering valve to 0 position. H set unit switch to position. H continue to run machine for approx. 1 minute, then set unit switch to 0 position. H operate spray gun until machine is depressurised. H lock operating lever. This lock must be engaged even when interrupting work f...

  • Page 13

    1 3 3 care and maintenance 3.1. Important safety information caution! Always pull power plug before working on machine! Your high-pressure cleaning machine will remain operable for years to come if you treat it with care. Use only genuine wap accessories and spare parts. The maintenance work marked ...

  • Page 14

    1 4 water hardness in °dh setting on potentiometer 0 - 15 1 16 - 30 2 3.2.6 adjusting wap automatic calcification alarm the automatic calcification alarm is preadjusted at the factory. However, should an adjustment be necessary, proceed as follows: h measure water hardness or obtain water-hardness r...

  • Page 15

    1 5 weekly or every 40 operating hours quarterly or every 200 operating hours annually or every 500 operating hours as required check oil level x change pump oil x clean screens and filters in water supply system x clean heat exchanger x clean ignition system x clean fuel system x grease hand-tighte...

  • Page 16

    1 6 fault cause remedy f) oil jet plugged (see b b)) clean nozzle and screen and replace if necessary g) oil filter dirty (see b b)) clean filter h) oil pump or coupling defective (see c a), b)) replace oil pump or coupling i) water quantity too low see d a) - f) for cause c burner produces soot a) ...

  • Page 17

    1 7 3.5 accessories, spare parts depending on the type of dirt and cleaning task, the corresponding nozzles can be used. The working pressure depends on the high-pressure nozzle. The required nozzle can be found in the following nozzle table. For high-pressure hose over 50 m in length, use the next ...

  • Page 18

    1 8 wap reinigungssysteme gmbh & co. Guido-oberdorfer-straße 2-8 d-89287 bellenberg eu declaration of conformity as defined by the eu machine directive 89/392/ewg, appendix iia we herewith declare that the design of the high-pressure cleaner wap sc 702, item no. 49128 wap sc 730, item no. 49130 wap ...

  • Page 19

    1 9.

  • Page 20

    Internet http://www.Alto-online.Com alto headquarters incentive international a/s kongens nytorv 28 p.O.Box 2064 1013 copenhagen k tel.: +45 33 11 11 42 fax: +45 33 93 46 36 e-mail: incentive@incentive-dk.Com subsidiaries australia alto overseas inc. 1b/8 resolution drive p.O.Box 797 caringbah, n.S....