Wasp WDI4600 Product Reference Manual

Other manuals for WDI4600: Quick Reference Manual
Manual is about: 1D 2D Digital Scanner USB

Summary of WDI4600

  • Page 1

    Wdi4600 1d 2d digital scanner usb product reference guide.

  • Page 2

    Wasp barcode technologies 1400 10th street plano, texas usa 75074 tel. 214-547-4100 tel. 214-547-4101 ©2000-2013 wasp barcode technologies, inc. (an unpublished work provided under license). Patents this product may be covered by one or more of the following patents: design patents: cn zl20083014238...

  • Page 3: Table of Contents

    Product reference guide i table of contents introduction ................................................................................................................................................................................ 1 about this manual .................................................

  • Page 4

    Ii wdi4600 usb keyboard speed .....................................................................................................................................................................................................39 usb keyboard numeric keypad .............................................

  • Page 5

    Product reference guide iii upc-a 2d component ..................................................................................................................................................................................................84 upc-e .....................................................

  • Page 6

    Iv wdi4600 code 128 set length 1 ............................................................................................................................................................................................... 116 code 128 set length 2 ....................................................

  • Page 7

    Product reference guide v gs1 databar™ omnidirectional enable/disable ............................................................................................................................................... 150 gs1 databar™ omnidirectional gs1-128 emulation ......................................

  • Page 8

    Vi wdi4600 maxicode set length 2 .............................................................................................................................................................................................. 185 pdf417 ....................................................................

  • Page 9

    Product reference guide vii led and beeper indications .......................................................................................................................................................................243 error codes .................................................................

  • Page 10: Notes

    Viii wdi4600 notes.

  • Page 11: Chapter 1

    Product reference guide 1 chapter 1 introduction about this manual this product reference guide (prg) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The quick reference guide (qrg) and other publications associated wit...

  • Page 12: Manual Conventions

    Introduction references 2 wdi4600 manual conventions the following conventions are used in this document: the symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: notes contain information necessary for properly di...

  • Page 13: About The Reader

    About the reader introduction product reference guide 3 about the reader typically, units are factory-programmed for the most common terminal and communications settings. If you need to modify any programmable settings, custom configuration can be accomplished by scanning the programming bar codes w...

  • Page 14: Notes

    Introduction programming the reader 4 wdi4600 notes.

  • Page 15: Chapter 2

    Product reference guide 5 chapter 2 setup unpacking check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact wasp barcode technologies technical support. Information is shown on page 2 . Keep the packaging. Should the...

  • Page 16

    Setup installing the interface cable 6 wdi4600 installing the interface cable for corded versions, c onnect the reader cable by inserting the cable into the handle as shown in figure 1 . To remove it, insert a paper clip into the release aperture, then unplug the cable. Figure 1. Connect/disconnect ...

  • Page 17

    Installing the interface cable setup product reference guide 7 keyboard wedge connection the keyboard wedge cable has a ‘y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/pc. Reference figure 3 . Figure 3. K...

  • Page 18: Interface Selection

    Setup interface selection 8 wdi4600 figure 5. Other interface connections ib m k ey bo ard w edg e or... Specific cables are required for connection to different hosts. The connec- tors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect t...

  • Page 19

    Interface selection setup product reference guide 9 table 1. Available interfaces rs-232 features rs-232 standard interface select rs232-std set rs-232 interface features starting on page 19 $p,ha12,p(cr) select rs232-wn rs-232 wincor-nixdorf rs-232 for use with opos/upos/javapos $p,ha13,p(cr) selec...

  • Page 20

    Keyboard features $p,ha2b,p(cr) select usb alternate keyboard usb keyboard with alternate key encoding set keyboard wedge interface features starting on page 31 at, ps/2 25-286, 30-286, 50, 50z, 60, 70, 80, 90 & 95 w/standard key encoding $p,ha29,p(cr) select kbd-at $p,ha11,p(cr) select kbd-at-nk ke...

  • Page 21

    Keyboard (continued) features keyboard wedge for ibm terminals 31xx, 32xx, 34xx, 37xx make only key- board $p,ha15,p(cr) select kbd-ibm-m set keyboard wedge interface features starting on page 31 $p,ha16,p(cr) select kbd-ibm-mb keyboard wedge for ibm terminals 31xx, 32xx, 34xx, 37xx make break key- ...

  • Page 22: Configure Interface Settings

    Setup customizing configuration settings 12 wdi4600 customizing configuration settings configure interface settings if after scanning the interface barcode from the previous table, your installation requires you to select options to further customize your reader, turn to the appropriate section for ...

  • Page 23

    Customizing configuration settings setup product reference guide 13 resetting the product configuration to defaults restore custom defaults if you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the custom default configuration that may hav...

  • Page 24: Notes

    Setup customizing configuration settings 14 wdi4600 notes.

  • Page 25: Chapter 3

    Product reference guide 15 chapter 3 configuration using barcodes this and following sections provide programming barcodes to configure your reader by changing the default settings. For details about additional methods of programming, see " configuration methods" on page 3 . You must first enable yo...

  • Page 26

    Enter/exit programming mode 16 wdi4600 to program features: 1. Scan the enter/exit programming barcode, available at the top of each pro- gramming page, when applicable. 2. Scan the barcode to set the desired programming feature. You may need to cover unused barcodes on the page, and possibly the fa...

  • Page 27: Global Interface Features

    Global interface features enter/exit programming mode product reference guide 17 global interface features the following interface features are configurable by all interface types. Host commands — obey/ignore this option specifies whether the reader will obey or ignore host commands. When set to ign...

  • Page 28: Notes

    Enter/exit programming mode global interface features 18 wdi4600 notes.

  • Page 29: Rs-232 Interface

    Product reference guide 19 rs-232 interface b aud r ate on page 20 d ata b its on page 21 s top b its on page 21 p arity on page 22 h andshaking c ontrol on page 23 use the programming barcodes in this section if modifications to the standard rs-232 interface settings are necessary to meet your syst...

  • Page 30: Baud Rate

    Enter/exit programming mode rs-232 interface 20 wdi4600 baud rate see page 206 for information on this feature. $cr2ba00(cr) baud rate = 1200 $cr2ba01(cr) baud rate = 2400 $cr2ba02(cr) baud rate = 4800 $cr2ba03(cr) baud rate = 9600 default $cr2ba04(cr) baud rate = 19,200 $cr2ba05(cr) baud rate = 38,...

  • Page 31: Data Bits

    Rs-232 interface enter/exit programming mode product reference guide 21 data bits this parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ascii protocol for sending and receiving data. $cr2da00(cr) 7 data bits $cr2da01(cr) 8 data bits default stop bits set the number of...

  • Page 32: Parity

    Enter/exit programming mode rs-232 interface 22 wdi4600 parity this feature specifies parity required for sending and receiving data. Select the parity type according to host device requirements. See page 206 for more information. Default $cr2pa00(cr) parity = none $cr2pa01(cr) parity = even $cr2pa0...

  • Page 33: Handshaking Control

    Rs-232 interface enter/exit programming mode product reference guide 23 handshaking control default $cr2hc00(cr) handshaking control = rts $cr2hc01(cr) handshaking control = rts/cts $cr2hc02(cr) handshaking control = rts/xon/xoff $cr2hc03(cr) handshaking control = rts on/cts $cr2hc04(cr) handshaking...

  • Page 34: Rs-232/usb-Com Interfaces

    Product reference guide 24 rs-232/usb-com interfaces i ntercharacter d elay on page 25 b eep o n ascii bel on page 25 b eep o n n ot on f ile on page 26 ack nak o ptions on page 26 ack c haracter on page 27 nak c haracter on page 27 ack nak t imeout v alue on page 28 ack nak r etry c ount on page 28...

  • Page 35: Intercharacter Delay

    Rs-232/usb-com interfaces enter/exit programming mode product reference guide 25 intercharacter delay this parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increm...

  • Page 36: Beep On Not On File

    Enter/exit programming mode rs-232/usb-com interfaces 26 wdi4600 beep on not on file this option enables/disables the action of the reader to sound a three beep sequence upon receiving a not-on-file (nof) host command. $cbpnf00(cr) beep on not on file = disable default $cbpnf01(cr) beep on not on fi...

  • Page 37: Ack Character

    Rs-232/usb-com interfaces enter/exit programming mode product reference guide 27 ack character this setting specifies an ascii character or hex value to be used as the ack character. Ascii characters or any hex value from 0 to 0xff can be selected. See page 208 for more information. $cr2ac select ac...

  • Page 38: Ack Nak Timeout Value

    Enter/exit programming mode rs-232/usb-com interfaces 28 wdi4600 ack nak timeout value this option specifies the amount of time the reader waits for an ack character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increme...

  • Page 39: Ack Nak Error Handling

    Rs-232/usb-com interfaces enter/exit programming mode product reference guide 29 ack nak error handling this feature specifies the method the reader uses to handle receive errors detected while waiting for an ack character from the host. Default $cr2eh00(cr) ack nak error handling = ignore errors de...

  • Page 40: Disable Character

    Enter/exit programming mode rs-232/usb-com interfaces 30 wdi4600 disable character specifies the value of the rs-232 host command used to disable the reader. Ascii characters or any hex value from 0 to 0xff can be selected. Setting to previously defined characters such as xon, xoff, or host commands...

  • Page 41: Keyboard Settings

    Product reference guide 31 keyboard settings c ountry m ode on page 32 s end c ontrol c haracters on page 36 w edge q uiet i nterval on page 37 i ntercode d elay on page 37 c aps l ock s tate on page 38 n umlock on page 38 usb k eyboard s peed on page 39 usb k eyboard n umeric k eypad on page 40 use...

  • Page 42: Country Mode

    Enter/exit programming mode keyboard settings 32 wdi4600 country mode this feature specifies the country/language supported by the keyboard. Several languages are supported: default $ckbco00(cr) country mode = u.S. $ckbco01(cr) country mode = belgium $ckbco02(cr) country mode = britain $ckbco11(cr) ...

  • Page 43

    Keyboard settings enter/exit programming mode product reference guide 33 country mode (continued) $ckbco04(cr) country mode = france supports only the interfaces listed in the country mode feature description. $ckbco13(cr) country mode = french canadian $ckbco05(cr) country mode = germany supports o...

  • Page 44

    Enter/exit programming mode keyboard settings 34 wdi4600 country mode (continued) $ckbco14(cr) country mode = lithuanian supports only the interfaces listed in the country mode feature description. $ckbco07(cr) country mode = norway $ckbco12(cr) country mode = poland supports only the interfaces lis...

  • Page 45

    Keyboard settings enter/exit programming mode product reference guide 35 country mode (continued) $ckbco09(cr) country mode = spain $kbco0a(cr) country mode = sweden $ckbco0b(cr) country mode = switzerland supports only the interfaces listed in the country mode feature description..

  • Page 46: Send Control Characters

    Enter/exit programming mode keyboard settings 36 wdi4600 send control characters this feature specifies how the reader transmits ascii control characters to the host. Reference appendix e, scancode tables for more information about control characters. Options are as follows: control character 00 : c...

  • Page 47: Wedge Quiet Interval

    Keyboard settings enter/exit programming mode product reference guide 37 wedge quiet interval specifies amount of time to look for keyboard activity before scanner breaks keyboard connection in order to transmit data to host. The selectable range for this setting is 00 to 990 milliseconds (00-0x63 b...

  • Page 48: Caps Lock State

    Enter/exit programming mode keyboard settings 38 wdi4600 caps lock state this option specifies the format in which the reader sends character data. This does not apply when an alternate key encoding keyboard is selected. Default $ckbcl00(cr) caps lock state = caps lock off $ckbcl01(cr) caps lock sta...

  • Page 49: Usb Keyboard Speed

    Keyboard settings enter/exit programming mode product reference guide 39 usb keyboard speed this option specifies the usb poll rate for a usb keyboard. Default $ckbsp01(cr) usb keyboard speed = 1ms $ckbsp02(cr) usb keyboard speed = 2ms $ckbsp03(cr) usb keyboard speed = 3ms $ckbsp04(cr) usb keyboard ...

  • Page 50: Usb Keyboard Numeric Keypad

    $ckbsp07(cr) usb keyboard speed = 7ms $ckbsp08(cr) usb keyboard speed = 8ms $ckbsp09(cr) usb keyboard speed = 9ms $ckbsp0a(cr) usb keyboard speed = 10ms enter/exit programming mode keyboard settings 40 wdi4600 usb keyboard speed (continued) usb keyboard numeric keypad this option controls whether nu...

  • Page 51: Usb-Oem Interface

    Product reference guide 41 usb-oem interface usb-oem d evice u sage on page 42 i nterface o ptions on page 42 feature settings for usb interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the usb- o...

  • Page 52: Usb-Oem Device Usage

    Enter/exit programming mode usb-oem interface 42 wdi4600 usb-oem device usage the usb-oem protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a usb-oem pos, you may need to change this s...

  • Page 53: Data Format

    Product reference guide 43 data format g lobal p refix /s uffix starting on page 44 g lobal aim id starting on page 45 l abel id starting on page 48 • label id: pre-loaded sets • individually set label id • label id control • label id symbology selection • 1d symbologies • label id symbology selecti...

  • Page 54: Global Prefix/suffix

    Enter/exit programming mode data format 44 wdi4600 global prefix/suffix this option sets up to 20 characters each from the set of ascii characters or any hex value from 00 to ff. The characters may be added as a prefix (in a position before the barcode data, also called a header) and/or as a suffix ...

  • Page 55: Global Aim Id

    Data format enter/exit programming mode product reference guide 45 global aim id this feature enables/disables addition of aim ids for all symbology types. Aim label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data....

  • Page 56

    Enter/exit programming mode data format 46 wdi4600 databar expanded composite e 65 databar limited e 65 databar limited composite e 65 data matrix d 64 ean128 c 43 ean128 composite c 43 ean13 e 45 ean13 p2 e 45 ean13 p5 e 45 ean13 composite e 45 ean8 e 45 ean8 p2 e 45 ean8 p5 e 45 ean8 composite e 4...

  • Page 57

    Data format enter/exit programming mode product reference guide 47 set aim id individually for gs1-128 this feature configures a label id individually for the gs1-128 symbology and the programming for this works the same way as label id. See label id: set individually per symbology, starting on page...

  • Page 58: Label Id

    Enter/exit programming mode data format 48 wdi4600 label id a label id is a customizable code of up to three ascii characters (convert to hex using the ascii chart on the inside back cover of this manual), used to identify a barcode symbology type. It can be appended previous to or following the tra...

  • Page 59: Individually Set Label Id

    Data format enter/exit programming mode product reference guide 49 individually set label id this feature configures a label id individually for a single symbology. To set, first define whether you want it as a prefix or suffix by scanning a label below. Then turn to label id symbology selection • 1...

  • Page 60: Label Id Symbology Selection

    Enter/exit programming mode data format 50 wdi4600 label id symbology selection − 1d symbologies this option selects the symbology for which a label id is to be configured. See "label id" on page 48 or page 224 in “references” for more detailed instructions. $cacid if less than the expected string o...

  • Page 61

    Data format enter/exit programming mode product reference guide 51 label id symbology selection − 1d symbologies (continued) $cccid set code 39 cip label id character(s) $c35id set ean 13 p5 label id character(s) $c8bid set ean 8 label id character(s) $cxcid set gs1 databar expanded composite label ...

  • Page 62

    Enter/exit programming mode data format 52 wdi4600 label id symbology selection − 1d symbologies (continued) $cxbid set gs1 databar expanded label id character(s) $cgbid set gtin 8 label id character(s) $ciaid set iata industrial 2 of 5 label id character(s) $clpid set laposte code 39 label id chara...

  • Page 63

    Data format enter/exit programming mode product reference guide 53 label id symbology selection − 1d symbologies (continued) $cpzid set pzn code label id character(s) $cpbid set postnet bb label id character(s) $cprid set royal postal code label id character(s) $camid set upc-a composite label id ch...

  • Page 64

    $cazid set aztec label id character(s) $cmxid set maxicode label id character(s) $ccsid set china sensible label id character(s) $cp4id set pdf 417 label id character(s) $cdmid set data matrix label id character(s) $cmiid set micro pdf 417 label id character(s) $cmqid set micro qr label id character...

  • Page 65: Case Conversion

    Data format enter/exit programming mode product reference guide 55 advanced formatting: user label edit advanced formatting is available to create user label edit scripts. Contact wasp technical support for information. Case conversion this feature allows conversion of the case of all alphabetic cha...

  • Page 66: Character Conversion

    Enter/exit programming mode data format 56 wdi4600 character conversion character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ascii values. The first character in the pair is the character that will be converted. The second charact...

  • Page 67: Reading Parameters

    Product reference guide 57 reading parameters d ouble r ead t imeout starting on page 58 led and b eeper i ndicators starting on page 60 • power on alert • good read: when to indicate • good read beep type • good read beep frequency • good read beep length • good read beep volume • good read led dur...

  • Page 68: Double Read Timeout

    Enter/exit programming mode reading parameters 58 wdi4600 double read timeout double read timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the sp...

  • Page 69

    Reading parameters enter/exit programming mode product reference guide 59 double read timeout (continued) $csndr50(cr) double read timeout = 0.8 second $csndr5a(cr) double read timeout = 0.9 second $csndr64(cr) double read timeout = 1 second.

  • Page 70: Led and Beeper Indicators

    Enter/exit programming mode reading parameters 60 wdi4600 led and beeper indicators power on alert disables or enables the indication (from the beeper) that the reader is receiving power. $cbppu00(cr) power on alert = disable (no audible indication) $cbppu01(cr) power on alert = power-up beep defaul...

  • Page 71: Good Read Beep Type

    Reading parameters enter/exit programming mode product reference guide 61 good read beep type specifies whether the good read beep has a mono or bitonal beep sound. Default $cbpty00(cr) good read beep type = mono $cbpty01(cr) good read beep type = bitonal good read beep frequency adjusts the good re...

  • Page 72: Good Read Beep Length

    Enter/exit programming mode reading parameters 62 wdi4600 good read beep length $cbple06(cr) good read beep length = 60 msec $cbple08(cr) good read beep length = 80 msec default $cbple0a(cr) good read beep length = 100 msec $cbple0c(cr) good read beep length = 120 msec $cbple0e(cr) good read beep le...

  • Page 73: Good Read Beep Volume

    Reading parameters enter/exit programming mode product reference guide 63 good read beep volume selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels. $cbpvo00cr) good read beep volume = beeper off $cbpvo01cr) good read beep volume = low $cbpvo02cr) goo...

  • Page 74: Good Read Led Duration

    Enter/exit programming mode reading parameters 64 wdi4600 good read led duration this feature specifies the amount of time that the good read led remains on following a good read. The good read led on time can be set within a range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in ...

  • Page 75: Scanning Features

    Reading parameters enter/exit programming mode product reference guide 65 scanning features scan mode selects the reader’s scan operating mode. See page 228 in “references” for descriptions. $csnrm00(cr) scan mode = trigger single default $csnrm01(cr) scan mode = trigger hold multiple $csnrm02(cr) s...

  • Page 76: Stand Mode Indication

    Enter/exit programming mode reading parameters 66 wdi4600 stand mode indication this operation is useful for indicating when the reader is in stand mode. If enabled, the blue indicator will blink when stand mode scanning is active. If reader detects motion and switches out of stand mode into trigger...

  • Page 77: Stand Operation

    Reading parameters enter/exit programming mode product reference guide 67 stand operation specifies the behavior of the reader when stationary in a stand. When configured for stand mode, the reader will switch to stand mode when stationary. Below are further options concerning stand operation. Ignor...

  • Page 78: Pick Mode

    Enter/exit programming mode reading parameters 68 wdi4600 pick mode specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet. This...

  • Page 79: Scanning Active Time

    Reading parameters enter/exit programming mode product reference guide 69 stand mode illumination off time specifies the amount of time reader illumination stays off after pulling the trigger when in stand mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). S...

  • Page 80: Stand Illumination Control

    Enter/exit programming mode reading parameters 70 wdi4600 stand illumination control controls the illumination status while the reading mode is stand mode and the reader is attempting to detect objects. Default $csmil00(cr) stand illumination control = off $csmil01(cr) stand illumination control = o...

  • Page 81: Flash On Time

    Reading parameters enter/exit programming mode product reference guide 71 flash on time this feature specifies the on time for the indicator led while in flash mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. See page 232 in “references” fo...

  • Page 82: Aiming Pointer

    Enter/exit programming mode reading parameters 72 wdi4600 aiming pointer enables/disables the aiming pointer for all symbologies. $ctaap00(cr) aiming pointer = disable $ctaap01(cr) aiming pointer = enable default aiming duration timer specifies the frame of time the aiming pointer remains on after d...

  • Page 83: Green Spot Duration

    Reading parameters enter/exit programming mode product reference guide 73 green spot duration specifies the duration of the good read pointer beam after a good read. $clssp00(cr) green spot duration = disable (green spot is off ) $clssp01(cr) green spot duration = short (300 msec) default $clssp02(c...

  • Page 84: Decode Negative Image

    Enter/exit programming mode reading parameters 74 wdi4600 partial label reading control enable/disable to ignore partial labels to be read within the boundary of the field of view. Ippl00 partial label reading control = disable ippl01 partial label reading control = enable decode negative image enab...

  • Page 85: Corded Only Features

    Reading parameters enter/exit programming mode product reference guide 75 corded only features corded stand mode sets the stand mode operation for corded models default $csmvs00(cr) corded stand mode = disable $csmvs01(cr) corded stand mode = generic stand $csmvs02(cr) corded stand mode = for all-in...

  • Page 86: Corded Stand Beep

    Enter/exit programming mode reading parameters 76 wdi4600 corded stand beep enables/disables the beep that indicates when corded stand position is detected. Default $cbpvs00(cr) corded stand beep = disable $cbpvs01(cr) corded stand beep = enable this feature is available starting on firmware release...

  • Page 87: Multiple Label Reading

    Reading parameters enter/exit programming mode product reference guide 77 multiple label reading in standard (default) mode, when the reader’s aiming system is activated (by a trigger pull, motion or other method depending on the mode), it then acquires and processes each image in the area in front ...

  • Page 88

    Enter/exit programming mode reading parameters 78 wdi4600 multiple labels ordering by code symbology this feature allows you to specify the order multiple labels are transmitted by symbology type, when multiple labels per frame is enabled. See page 234 in “references” for detailed information on set...

  • Page 89: 1D Symbologies

    Product reference guide 79 1d symbologies 1d code selection the reader supports the following 1d symbologies (barcode types). See "2d symbologies" starting on page 171 for 2d barcodes. Symbology-dependent options are included in each chapter. • disable all symbologies, page 80 • gs1-128, page 118 • ...

  • Page 90: Disable All Symbologies

    Enter/exit programming mode disable all symbologies 80 wdi4600 4. Complete the programming sequence by scanning the enter/exit program- ming barcode to exit programming mode. Disable all symbologies use this feature to disable all symbologies. 1. Scan the enter/exit programming mode barcode. 2. Scan...

  • Page 91: Code Ean/upc

    Code ean/upc enter/exit programming mode product reference guide 81 code ean/upc coupon control this feature is used to control the reader’s method of processing coupon labels. $ccplc00(cr) coupon control = allow all coupon barcodes to be decoded $ccplc01(cr) coupon control = enable only upca coupon...

  • Page 92: Upc-A

    Enter/exit programming mode code ean/upc 82 wdi4600 upc-a the following options apply to the upc-a symbology. Upc-a enable/disable when disabled, the reader will not read upc-a barcodes. $caben00(cr) upc-a = disable $caben01(cr) upc-a = enable default upc-a check character transmission enable this o...

  • Page 93: Expand Upc-A to Ean-13

    Code ean/upc enter/exit programming mode product reference guide 83 expand upc-a to ean-13 expands upc-a data to the ean-13 data format. Selecting this feature also changes the symbology id to match those required for ean-13. Default $cab3b00(cr) upc-a to ean-13 = don’t expand $cab3b01(cr) upc-a to ...

  • Page 94: Upc-A 2D Component

    Enter/exit programming mode upc-e 84 wdi4600 upc-a 2d component this feature enables/disables a requirement that a 2d label component be decoded when a base label of this symbology is decoded. Default $cab2d00(cr) ean-13 2d component = disable (2d component not required) $cab2d01(cr) ean-13 2d compo...

  • Page 95: Upc-E 2D Component

    Upc-e enter/exit programming mode product reference guide 85 upc-e check character transmission enable this option to transmit the check character along with upc-e barcode data. $cebct00(cr) upc-e check character transmission = don’t send $cebct01(cr) upc-e check character transmission = send defaul...

  • Page 96: Expand Upc-E to Ean-13

    Enter/exit programming mode upc-e 86 wdi4600 expand upc-e to ean-13 expands upc-e data to the ean-13 data format. Selecting this feature also changes the symbology id to match those required for ean-13. Default $ceb3b00(cr) upc-e to ean-13 = don’t expand $ceb3b01(cr) upc-e to ean-13 = expand expand ...

  • Page 97: Gtin Formatting

    Gtin formatting enter/exit programming mode product reference guide 87 upc-e number system character transmission this feature enables/disables transmission of the upc-e system number character. $cebns00(cr) upc-e number system character = do not transmit $cebns01(cr) upc-e number system character =...

  • Page 98: Ean 13 (Jan 13)

    Enter/exit programming mode ean 13 (jan 13) 88 wdi4600 ean 13 (jan 13) the following options apply to the ean 13 (jan 13) symbology. Ean 13 enable/disable when disabled, the reader will not read ean 13/jan 13 barcodes. $c3ben00(cr) ean 13 = disable $c3ben01(cr) ean 13 = enable default ean 13 check c...

  • Page 99: Ean-13 Flag 1 Character

    Ean 13 (jan 13) enter/exit programming mode product reference guide 89 ean-13 flag 1 character enables/disables transmission of an ean/jan13 flag1 character. The flag 1 character is the first character of the label. $c3bf100(cr) ean-13 flag 1 char= don’t transmit $c3bf101(cr) ean-13 flag 1 char= tra...

  • Page 100: Ean-13 2D Component

    Enter/exit programming mode issn 90 wdi4600 ean-13 2d component this feature enables/disables a requirement that a 2d label component be decoded when a base label of this symbology is decoded. Default $c3b2d00(cr) ean-13 2d component = disable (2d component not required) $c3b2d01(cr) ean-13 2d compo...

  • Page 101: Ean 8 (Jan 8)

    Ean 8 (jan 8) enter/exit programming mode product reference guide 91 ean 8 (jan 8) the following options apply to the ean 8 (jan 8) symbology. Ean 8 enable/disable when disabled, the reader will not read ean 8/jan 8 barcodes. $c8ben00(cr) ean 8 = disable $c8ben01(cr) ean 8 = enable default ean 8 che...

  • Page 102: Expand Ean 8 to Ean 13

    Enter/exit programming mode ean 8 (jan 8) 92 wdi4600 expand ean 8 to ean 13 enable this option to expand ean 8/jan 8 labels to ean 13/jan 13. Default $c8b3b00(cr) expand ean 8 to ean 13 = disable $c8b3b01(cr) expand ean 8 to ean 13 = enable ean 8 2d component this feature enables/disables a requirem...

  • Page 103: Upc/ean Global Settings

    Upc/ean global settings enter/exit programming mode product reference guide 93 upc/ean global settings this section provides configuration settings for upc-a, upc-e, ean 13 and ean 8 symbologies, and affects all of these unless otherwise marked for each feature description. Upc/ean price weight chec...

  • Page 104: Upc/ean Quiet Zones

    Enter/exit programming mode upc/ean global settings 94 wdi4600 upc/ean quiet zones this feature specifies the number of quiet zones for upc/ean labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label. The property applies ...

  • Page 105: Add-Ons

    Add-ons enter/exit programming mode product reference guide 95 add-ons contact customer support for advanced programming of optional and conditional add-ons. Optional add-ons the reader can be enabled to optionally read the following add-ons (supplementals): default $cado200(cr) optional add-ons = d...

  • Page 106: Optional Add-On Timer

    Enter/exit programming mode add-ons 96 wdi4600 optional add-on timer this option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (also see "optional gs1-128 add-on timer" on page 99.) $cadot01(cr) optional add-on timer = 10ms $...

  • Page 107

    $cadot06(cr) optional add-on timer = 60ms $cadot07(cr) optional add-on timer = 70ms default $cadot0a(cr) optional add-on timer = 100ms $cadot0c(cr) optional add-on timer = 120ms $cadot0e(cr) optional add-on timer = 140ms $cadot10(cr) optional add-on timer = 160ms add-ons enter/exit programming mode ...

  • Page 108

    $cadot12(cr) optional add-on timer = 180ms $cadot14(cr) optional add-on timer = 200ms $cadot16(cr) optional add-on timer = 220ms $cadot18(cr) optional add-on timer = 240ms $cadot1a(cr) optional add-on timer = 260ms $cadot1c(cr) optional add-on timer = 280ms $cadot1e(cr) optional add-on timer = 300ms...

  • Page 109

    Add-ons enter/exit programming mode product reference guide 99 optional gs1-128 add-on timer this option sets the timer expiration value to read the added part after reading the linear ean/ upc part. For upc/ean add-ons other than those of that type, see "optional add-on timer" on page 96. Default $...

  • Page 110

    $cadut06(cr) optional gs1-128 add-on timer = 60ms $cadut07(cr) optional gs1-128 add-on timer = 70ms $cadut0a(cr) optional gs1-128 add-on timer = 100ms $cadut0c(cr) optional gs1-128 add-on timer = 120ms $cadut0e(cr) optional gs1-128 add-on timer = 140ms $cadut10(cr) optional gs1-128 add-on timer = 16...

  • Page 111

    $cadut12(cr) optional gs1-128 add-on timer = 180ms $cadut14(cr) optional gs1-128 add-on timer = 200ms $cadut16(cr) optional gs1-128 add-on timer = 220ms $cadut18(cr) optional gs1-128 add-on timer = 240ms $cadut1a(cr) optional gs1-128 add-on timer = 260ms $cadut1c(cr) optional gs1-128 add-on timer = ...

  • Page 112: Code 39

    Enter/exit programming mode code 39 102 wdi4600 code 39 the following options apply to the code 39 symbology. Code 39 enable/disable $cc3en00(cr) code 39 = disable $cc3en01(cr) code 39 = enable default code 39 check character calculation enable this option to enables/disables calculation and verific...

  • Page 113

    Code 39 enter/exit programming mode product reference guide 103 code 39 check character transmission enable this option to transmit the check character along with code 39 barcode data. $cc3ct00(cr) code 39 check character transmission = don’t send $cc3ct01(cr) code 39 check character transmission = ...

  • Page 114: Code 39 Full Ascii

    Enter/exit programming mode code 39 104 wdi4600 code 39 start/stop character transmission enable this option to enable/disable transmission of code 39 start and stop characters default $cc3ss00(cr) code 39 start/stop character transmission = don’t transmit $cc3ss01(cr) code 39 start/stop character t...

  • Page 115: Code 39 Quiet Zones

    Code 39 enter/exit programming mode product reference guide 105 code 39 quiet zones this feature specifies the number of quiet zones for code 39 labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label. $cc3lo02(cr) code 39...

  • Page 116: Code 39 Set Length 1

    Enter/exit programming mode code 39 106 wdi4600 code 39 set length 1 this feature specifies one of the barcode lengths for code 39 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the barcode’s data c...

  • Page 117: Code 39 Set Length 2

    Code 39 enter/exit programming mode product reference guide 107 code 39 set length 2 this feature specifies one of the barcode lengths for code 39 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes the...

  • Page 118: Trioptic Code

    Enter/exit programming mode trioptic code 108 wdi4600 trioptic code the following options apply to the trioptic symbology. Trioptic code enable/disable default $ccten00(cr) trioptic code = disable $ccten01(cr) trioptic code = enable code 32 (ital pharmaceutical code) the following options apply to t...

  • Page 119

    Code 32 (ital pharmaceutical code) enter/exit programming mode product reference guide 109 code 32 feature setting exceptions the following features are set for code 32 by using these code 39 settings: "code 39 quiet zones" on page 105 "code 39 length control" on page 105 "trioptic code" on page 108...

  • Page 120: Code 39 Cip Enable/disable

    Enter/exit programming mode code 39 cip (french pharmaceutical) 110 wdi4600 code 39 cip (french pharmaceutical) the following options apply to the code 39 cip symbology. Code 39 cip enable/disable enables/disables ability of the reader to decode code 39 cip labels. Default $cccen00(cr) code 39 cip =...

  • Page 121: Code 39 Laposte

    Code 39 laposte enter/exit programming mode product reference guide 111 code 39 laposte the following options apply to the code 39 laposte symbology. Code 39 laposte enable/disable enables/disables the ability of the scanner to decode code39 la poste labels. Default $clpen00(cr) code 39 laposte = di...

  • Page 122: Code 128

    Enter/exit programming mode code 128 112 wdi4600 code 128 the following options apply to the code 128 symbology. Code 128 enable/disable when disabled, the reader will not read code 128 barcodes. $cc8en00(cr) code 128 = disable $cc8en01(cr) code 128 = enable default expand code 128 to code 39 this f...

  • Page 123

    Code 128 enter/exit programming mode product reference guide 113 code 128 check character transmission enable this option to transmit the check character along with code 128 barcode data. Default $cc8ct00(cr) code 128 check character transmission = don’t send $cc8ct01(cr) code 128 check character tr...

  • Page 124: Code 128 Quiet Zones

    Enter/exit programming mode code 128 114 wdi4600 code 128 sub-code exchange transmission enables/disables the transmission of “sub-code exchange” characters (not transmitted by standard decoding). Default $cc8sc00(cr) code 128 sub-code exchange transmission = disable $cc8sc01(cr) code 128 sub-code e...

  • Page 125: Code 128 Length Control

    Code 128 enter/exit programming mode product reference guide 115 code 128 length control this feature specifies either variable length decoding or fixed length decoding for the code 128 symbology. See page 217 for more information. Default $cc8lc00(cr) code 128 length control = variable length $cc8l...

  • Page 126: Code 128 Set Length 1

    Enter/exit programming mode code 128 116 wdi4600 code 128 set length 1 specifies one of the barcode lengths for code 128 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the barcode’s data characters ...

  • Page 127: Code 128 Set Length 2

    Code 128 enter/exit programming mode product reference guide 117 code 128 set length 2 this feature specifies one of the barcode lengths for code 128 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes ...

  • Page 128: Gs1-128

    Enter/exit programming mode gs1-128 118 wdi4600 gs1-128 the following options apply to the gs1-128 symbology. (also known as uss-128, gs1-128, gtin-128, ucc-128, ean-128.) gs1-128 enable this option enables/disables the ability of the reader to translate gs1-128 labels to the gs1-128 data format. Op...

  • Page 129: Code Isbt 128

    Code isbt 128 enter/exit programming mode product reference guide 119 code isbt 128 the following options apply to the isbt 128 symbology. Isbt 128 concatenation use this option to enable/disable isbt128 concatenation of 2 labels. Default $ci8ce00(cr) isbn 128 concatenation = disable $ci8ce01(cr) is...

  • Page 130: Isbt 128 Concatenation Mode

    Enter/exit programming mode code isbt 128 120 wdi4600 isbt 128 concatenation mode specifies the concatenation mode between static and dynamic. Default $ci8cm00cr) isbt 128 concatenation mode = static $ci8cm01cr) isbt 128 concatenation mode = dynamic this option is only valid when isbt 128 concatenat...

  • Page 131

    Code isbt 128 enter/exit programming mode product reference guide 121 isbt 128 dynamic concatenation timeout specifies the timeout used by the isbt 128 dynamic concatenation mode. $ci8dt05(cr) isbt 128 dynamic concatenation timeout = 50 msec $ci8dt0a(cr) isbt 128 dynamic concatenation timeout = 100 ...

  • Page 132: I 2 of 5 Enable/disable

    Enter/exit programming mode interleaved 2 of 5 (i 2 of 5) 122 wdi4600 interleaved 2 of 5 (i 2 of 5) the following options apply to the i 2 of 5 symbology. I 2 of 5 enable/disable when disabled, the reader will not read i 2 of 5 barcodes. Default $ci2en00(cr) i 2 of 5 = disable $ci2en01(cr) i 2 of 5 ...

  • Page 133

    Interleaved 2 of 5 (i 2 of 5) enter/exit programming mode product reference guide 123 i 2 of 5 check character calculation this option enables/disables calculation and verification of an optional i 2 of 5 check character . Default $ci2cc00(cr) i 2 of 5 check character calculation = disable $ci2cc01(...

  • Page 134: I 2 of 5 Length Control

    Enter/exit programming mode interleaved 2 of 5 (i 2 of 5) 124 wdi4600 i 2 of 5 check character transmission enable this option to transmit the check character along with i 2 of 5 barcode data. $ci2ct00(cr) i 2 of 5 check character transmission = don’t send $ci2ct01(cr) i 2 of 5 check character trans...

  • Page 135: I 2 of 5 Set Length 1

    Interleaved 2 of 5 (i 2 of 5) enter/exit programming mode product reference guide 125 i 2 of 5 set length 1 this feature specifies one of the barcode lengths for i 2 of 5 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mo...

  • Page 136: I 2 of 5 Set Length 2

    Enter/exit programming mode interleaved 2 of 5 (i 2 of 5) 126 wdi4600 i 2 of 5 set length 2 this feature specifies one of the barcode lengths for i 2 of 5 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. The length ...

  • Page 137: Interleaved 2 of 5 Cip Hr

    Interleaved 2 of 5 cip hr enter/exit programming mode product reference guide 127 interleaved 2 of 5 cip hr the following options apply to the interleaved 2 of 5 cip hr symbology. Interleaved 2 of 5 cip hr enable/disable enables/disables ability of reader to decode interleaved 2 of 5 cip hr labels. ...

  • Page 138: Standard 2 of 5

    Enter/exit programming mode standard 2 of 5 128 wdi4600 standard 2 of 5 the following options apply to the standard 2 of 5 symbology. Standard 2 of 5 enable/disable when disabled, the reader will not read standard 2 of 5 barcodes. Default $c2sen00(cr) standard 2 of 5 = disable $c2sen01(cr) standard ...

  • Page 139

    Standard 2 of 5 enter/exit programming mode product reference guide 129 standard 2 of 5 check character transmission this feature enables/disables transmission of an optional standard 2 of 5 check character. $cs2ct00(cr) standard 2 of 5 check character transmission = don’t send $cs2ct01(cr) standard...

  • Page 140: Standard 2 of 5 Set Length 1

    Enter/exit programming mode standard 2 of 5 130 wdi4600 standard 2 of 5 set length 1 this feature specifies one of the barcode lengths for standard 2 of 5 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length inclu...

  • Page 141: Standard 2 of 5 Set Length 2

    Standard 2 of 5 enter/exit programming mode product reference guide 131 standard 2 of 5 set length 2 this feature specifies one of the barcode lengths for standard 2 of 5 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length m...

  • Page 142: Industrial 2 of 5

    Enter/exit programming mode industrial 2 of 5 132 wdi4600 industrial 2 of 5 the following options apply to the industrial 2 of 5 symbology. Industrial 2 of 5 enable/disable enables/disables ability of reader to decode industrial 2 of 5 labels. Default $cu2en00(cr) industrial 2 of 5 = disable $cu2en0...

  • Page 143

    Industrial 2 of 5 enter/exit programming mode product reference guide 133 industrial 2 of 5 check character transmission enables/disables transmission of an industrial 2 of 5 check character. $cu2ct00(cr) industrial 2 of 5 check character transmission = disable $cu2ct01(cr) industrial 2 of 5 check c...

  • Page 144

    Enter/exit programming mode industrial 2 of 5 134 wdi4600 industrial 2 of 5 set length 1 this feature specifies one of the barcode lengths for industrial 2 of 5 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length...

  • Page 145

    Industrial 2 of 5 enter/exit programming mode product reference guide 135 industrial 2 of 5 set length 2 this feature specifies one of the barcode lengths for industrial 2 of 5 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed le...

  • Page 146: Code Iata

    Enter/exit programming mode code iata 136 wdi4600 code iata the following options apply to the iata symbology. Iata enable/disable enables/disables the ability of the reader to decode iata labels. Default $ciaen00(cr) iata = disable $ciaen01(cr) iata = enable iata check character transmission enable...

  • Page 147: Codabar

    Codabar enter/exit programming mode product reference guide 137 codabar the following options apply to the codabar symbology. Codabar enable/disable when disabled, the reader will not read codabar barcodes. Default $ccben00(cr) codabar = disable $ccben01(cr) codabar = enable codabar check character ...

  • Page 148

    Enter/exit programming mode codabar 138 wdi4600 codabar check character transmission enable this option to transmit the check character along with codabar barcode data. $ccbct00(cr) codabar check character transmission = don’t send $ccbct01(cr) codabar check character transmission = send default cod...

  • Page 149

    Codabar enter/exit programming mode product reference guide 139 codabar start/stop character set this option specifies the format of transmitted codabar start/stop characters $ccbsc00(cr) codabar check character set = abcd/tn*e $ccbsc01(cr) codabar check character set = abcd/abcd $ccbsc02(cr) codaba...

  • Page 150: Codabar Quiet Zones

    Enter/exit programming mode codabar 140 wdi4600 codabar quiet zones specifies the number of quiet zones for codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label. $ccblo02(cr) codabar quiet zones = quiet z...

  • Page 151: Codabar Set Length 1

    Codabar enter/exit programming mode product reference guide 141 codabar set length 1 this feature specifies one of the barcode lengths for codabar length controlcodabar length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode...

  • Page 152: Codabar Set Length 2

    Enter/exit programming mode codabar 142 wdi4600 codabar set length 2 this feature specifies one of the barcode lengths for codabar length controlcodabar length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. The length in...

  • Page 153: Abc Codabar

    Abc codabar enter/exit programming mode product reference guide 143 abc codabar the following options apply to the abc codabar symbology. Abc codabar enable/disable enables/disables ability of reader to decode abc codabar labels. Default $ccbab00(cr) abc codabar = disable $ccbab01(cr) abc codabar = ...

  • Page 154

    Enter/exit programming mode abc codabar 144 wdi4600 abc codabar dynamic concatenation timeout specifies the timeout in 10-millisecond ticks used by the abc codabar dynamic concatenation mode. $ccbdt05(cr) abc codabar dynamic concatenation timeout = 50 msec $ccbdt0a(cr) abc codabar dynamic concatenat...

  • Page 155

    Abc codabar enter/exit programming mode product reference guide 145 abc codabar force concatenation forces labels starting or ending with d to be concatenated. Default $ccbfc00(cr) abc codabar force concatenation = disable $ccbfc01(cr) abc codabar force concatenation = enable.

  • Page 156: Code 11

    Enter/exit programming mode code 11 146 wdi4600 code 11 the following options apply to the code 11 symbology. Code 11 enable/disable when disabled, the reader will not read code 11 barcodes. Default $cc1en00(cr) code 11 = disable $cc1en01(cr) code 11 = enable code 11 check character calculation this...

  • Page 157: Code 11 Length Control

    Code 11 enter/exit programming mode product reference guide 147 code 11 check character transmission this feature enables/disables transmission of an optional code 11 check character. $cc1ct00(cr) code 11 check character transmission = don’t send $cc1ct01(cr) code 11 check character transmission = s...

  • Page 158: Code 11 Set Length 1

    Enter/exit programming mode code 11 148 wdi4600 code 11 set length 1 this feature specifies one of the barcode lengths for code 11 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the barcode’s check ...

  • Page 159: Code 11 Set Length 2

    Code 11 enter/exit programming mode product reference guide 149 code 11 set length 2 this feature specifies one of the barcode lengths for code 11 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes the...

  • Page 160

    Enter/exit programming mode gs1 databar™ omnidirectional 150 wdi4600 gs1 databar™ omnidirectional the following options apply to the gs1 databar™ omnidirectional (formerly rss-14) symbology. Gs1 databar™ omnidirectional enable/disable when disabled, the reader will not read gs1 databar™ omnidirectio...

  • Page 161: Gs1 Databar™ Expanded

    Gs1 databar™ expanded enter/exit programming mode product reference guide 151 gs1 databar™ omnidirectional 2d component this feature enables/disables a requirement that a 2d label component be decoded when a base label for this symbology is decoded. Default $c4b2d00(cr) gs1 databar™ omnidirectional ...

  • Page 162

    Enter/exit programming mode gs1 databar™ expanded 152 wdi4600 gs1 databar™ expanded gs1-128 emulation when enabled, gs1 databar™ expanded barcodes will be translated to the gs1-128 label data format. Default $cxbu800(cr) gs1 databar™ expanded gs1-128 emulation = disable $cxbu801(cr) gs1 databar™ exp...

  • Page 163

    Gs1 databar™ expanded enter/exit programming mode product reference guide 153 gs1 databar™ expanded length control this feature specifies either variable length decoding or fixed length decoding for the gs1 databar™ expanded symbology. Variable length: for variable-length decoding, a minimum length ...

  • Page 164

    Enter/exit programming mode gs1 databar™ expanded 154 wdi4600 gs1 databar™ expanded set length 1 this feature specifies one of the barcode lengths for gs1 databar™ expanded length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length ...

  • Page 165

    Gs1 databar™ expanded enter/exit programming mode product reference guide 155 gs1 databar™ expanded set length 2 this feature specifies one of the barcode lengths for gs1 databar™ expanded length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if...

  • Page 166: Gs1 Databar™ Limited

    Enter/exit programming mode gs1 databar™ limited 156 wdi4600 gs1 databar™ limited the following options apply to the gs1 databar™ limited (formerly rss limited) symbology. Gs1 databar™ limited enable/disable when disabled, the reader will not read gs1 databar™ limited barcodes. Default $clben00(cr) ...

  • Page 167: Code 93

    Code 93 enter/exit programming mode product reference guide 157 gs1 databar™ limited 2d component this feature enables/disables a requirement that a 2d label component be decoded when a base label of this symbology is decoded. Default $clb2d00(cr) gs1 databar™ limited 2d component = disable (2d comp...

  • Page 168

    Enter/exit programming mode code 93 158 wdi4600 code 93 check character calculation enables/disables calculation and verification of an optional code 93 check character. $cc9cc00(cr) code 93 check character calculation = disable $cc9cc01(cr) code 93 check character calculation = enable check c $cc9c...

  • Page 169: Code 93 Length Control

    Code 93 enter/exit programming mode product reference guide 159 code 93 length control this feature specifies either variable length decoding or fixed length decoding for the code 93 symbology. Variable length: for variable length decoding, a minimum and maximum length may be set. Fixed length: for ...

  • Page 170: Code 93 Set Length 1

    Enter/exit programming mode code 93 160 wdi4600 code 93 set length 1 specifies one of the barcode lengths for code 93 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the barcode’s data characters onl...

  • Page 171: Code 93 Set Length 2

    Code 93 enter/exit programming mode product reference guide 161 code 93 set length 2 this feature specifies one of the barcode lengths for code 93 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes the...

  • Page 172: Code 93 Quiet Zones

    Enter/exit programming mode msi 162 wdi4600 code 93 quiet zones enables/disables quiet zones for code 93. $cc9lo02(cr) code 93 quiet zones = quiet zones on two sides $cc9lo03(cr) code 93 quiet zones = small quiet zones on two sides default msi the following options apply to the msi symbology. Msi en...

  • Page 173

    Msi enter/exit programming mode product reference guide 163 msi check character calculation enables/disables calculation and verification of an optional msi check character. $cmscc00(cr) msi check character calculation = disable $cmscc01(cr) msi check character calculation = enable mod10 default $cm...

  • Page 174: Msi Length Control

    Enter/exit programming mode msi 164 wdi4600 msi length control this feature specifies either variable length decoding or fixed length decoding for the msi symbology. Variable length: for variable length decoding, a minimum and maximum length may be set. Fixed length: for fixed length decoding, two d...

  • Page 175: Msi Set Length 1

    Msi enter/exit programming mode product reference guide 165 msi set length 1 this feature specifies one of the barcode lengths for msi length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the barcode’s da...

  • Page 176: Msi Set Length 2

    Enter/exit programming mode msi 166 wdi4600 msi set length 2 this feature specifies one of the barcode lengths for msi length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes the barcode’s check, data, and ...

  • Page 177: Plessey

    Plessey enter/exit programming mode product reference guide 167 plessey the following options apply to the plessey symbology. Plessey enable/disable enables/disables ability of reader to decode plessey labels. Default $cplen00cr) plessey = disable $cplen01cr) plessey = enable plessey check character...

  • Page 178: Plessey Length Control

    Enter/exit programming mode plessey 168 wdi4600 plessey check character transmission enables/disables transmission of an msi check character. $cplct00(cr) plessey check character transmission = disable $cplct01(cr) plessey check character transmission = enable default plessey length control this fea...

  • Page 179: Plessey Set Length 1

    Plessey enter/exit programming mode product reference guide 169 plessey set length 1 this feature specifies one of the barcode lengths for plessey length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the ...

  • Page 180: Plessey Set Length 2

    Enter/exit programming mode plessey 170 wdi4600 plessey set length 2 this feature specifies one of the barcode lengths for plessey length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes the barcode’s check...

  • Page 181: 2D Symbologies

    Product reference guide 171 2d symbologies 2d global features • 2d maximum decoding time, page 172 • 2d normal/inverse symbol control, page 173 • 2d structured append, page 173 the reader supports the following 2d symbologies (barcode types). Symbology-dependent options for each symbology are includ...

  • Page 182: 2D Maximum Decoding Time

    Enter/exit programming mode 2d global features 172 wdi4600 2d maximum decoding time this feature specifies the maximum amount of time the software will spend attempting to decode a 2d label. The selectable range is 10 milliseconds to 2.55 milliseconds. $cdetm0a(cr) 2d maximum decoding time = 100 mse...

  • Page 183: 2D Structured Append

    2d global features enter/exit programming mode product reference guide 173 2d structured append enables/disables ability of reader to append multiple 2d codes labels in a structured format. The structured append property is globally applied to the following symbologies, if these are enabled: • data ...

  • Page 184: Aztec Code

    Enter/exit programming mode aztec code 174 wdi4600 aztec code aztec code enable / disable enables/disables the ability of the reader to decode aztec code labels. Default $cazen00(cr) aztec code = disable $cazen01(cr) aztec code = enable aztec code length control this feature specifies either variabl...

  • Page 185: Aztec Code Set Length 1

    Aztec code enter/exit programming mode product reference guide 175 aztec code set length 1 specifies one of the barcode lengths for aztec code length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Characters can be set fr...

  • Page 186: Aztec Code Set Length 2

    Enter/exit programming mode aztec code 176 wdi4600 aztec code set length 2 this feature specifies one of the barcode lengths for aztec code length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Characters can be set from...

  • Page 187: China Sensible Code

    China sensible code enter/exit programming mode product reference guide 177 china sensible code china sensible code enable / disable enables/disables the ability of the reader to decode china sensible code labels. Default $ccsen00(cr) china sensible code = disable $ccsen01(cr) china sensible code = ...

  • Page 188: China Sensible Code

    Enter/exit programming mode china sensible code 178 wdi4600 china sensible code set length 1 specifies one of the barcode lengths for china sensible code length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Characters ca...

  • Page 189

    China sensible code enter/exit programming mode product reference guide 179 china sensible code set length 2 this feature specifies one of the barcode lengths for china sensible code length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fi...

  • Page 190: Data Matrix

    Enter/exit programming mode data matrix 180 wdi4600 data matrix data matrix enable / disable enables/disables ability of reader to decode data matrix labels . $cdmen00(cr) data matrix = disable $cdmen01(cr) data matrix = enable default data matrix square/rectangular style specifies the options avail...

  • Page 191: Data Matrix Length Control

    Data matrix enter/exit programming mode product reference guide 181 data matrix length control this feature specifies either variable length decoding or fixed length decoding for this symbology. Variable length: for variable length decoding, a minimum and maximum length may be set. Fixed length: for...

  • Page 192: Data Matrix Set Length 2

    Enter/exit programming mode data matrix 182 wdi4600 data matrix set length 2 this feature specifies one of the barcode lengths for data matrix length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Characters can be set f...

  • Page 193: Maxicode

    Maxicode enter/exit programming mode product reference guide 183 maxicode maxicode enable / disable enables/disables ability of reader to decode maxicode labels. Default $cmxen00(cr) maxicode = disable $cmxen01(cr) maxicode = enable maxicode primary message transmission enables/disables the transmis...

  • Page 194: Maxicode Length Control

    Enter/exit programming mode maxicode 184 wdi4600 maxicode length control this feature specifies either variable length decoding or fixed length decoding for this symbology. Variable length: for variable length decoding, a minimum and maximum length may be set. Fixed length: for fixed length decoding...

  • Page 195: Maxicode Set Length 2

    Maxicode enter/exit programming mode product reference guide 185 maxicode set length 2 this feature specifies one of the barcode lengths for maxicode length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Characters can b...

  • Page 196: Pdf417

    Enter/exit programming mode pdf417 186 wdi4600 pdf417 pdf417 enable / disable enables/disables the ability of the reader to decode pdf417 labels. $cp4en00(cr) pdf417 = disable $cp4en01(cr) pdf417 = enable default pdf417 length control this feature specifies either variable length decoding or fixed l...

  • Page 197: Pdf417 Set Length 1

    Pdf417 enter/exit programming mode product reference guide 187 pdf417 set length 1 specifies one of the barcode lengths for pdf417 length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Length includes the barcode’s data c...

  • Page 198: Pdf417 Set Length 2

    Enter/exit programming mode pdf417 188 wdi4600 pdf417 set length 2 this feature specifies one of the barcode lengths for pdf417 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Length includes the barcode’s check, d...

  • Page 199: Micro Pdf417

    Micro pdf417 enter/exit programming mode product reference guide 189 micro pdf417 micro pdf417 enable / disable enables/disables the ability of the reader to decode micro pdf417 labels default $cmien00(cr) micro pdf417 = disable $cmien01(cr) micro pdf417 = enable . Micro pdf417 code 128 gs1-128 emul...

  • Page 200: Micro Pdf417 Length Control

    Enter/exit programming mode micro pdf417 190 wdi4600 micro pdf417 length control this feature specifies either variable length decoding or fixed length decoding for this symbology. Variable length: for variable length decoding, a minimum and maximum length may be set. Fixed length: for fixed length ...

  • Page 201: Micro Pdf417 Set Length 2

    Micro pdf417 enter/exit programming mode product reference guide 191 micro pdf417 set length 2 this feature specifies one of the barcode lengths for micro pdf417 length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length includes t...

  • Page 202: Qr Code

    Enter/exit programming mode qr code 192 wdi4600 qr code qr code enable / disable enables/disables the ability of the reader to decode qr code labels $cqren00(cr) qr code = disable $cqren01(cr) qr code = enable default . Qr code length control this feature specifies either variable length decoding or...

  • Page 203: Qr Code

    Qr code enter/exit programming mode product reference guide 193 qr code set length 1 specifies one of the barcode lengths for qr code length control . Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Characters can be set from 0001 t...

  • Page 204: Qr Code

    Enter/exit programming mode qr code 194 wdi4600 qr code set length 2 this feature specifies one of the barcode lengths for qr code length control . Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Characters can be set from 0001 to ...

  • Page 205: Micro Qr Code

    Micro qr code enter/exit programming mode product reference guide 195 micro qr code micro qr code enable/disable enables/disables the ability of the reader to decode micro qr code labels default mqen00 micro qr code = disable mqen01 micro qr code = enable . Micro qr code length control this feature ...

  • Page 206: Micro Qr Code

    Enter/exit programming mode micro qr code 196 wdi4600 micro qr code set length 1 specifies one of the barcode lengths for micro qr code length control. Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode. Characters can be set from 0001 ...

  • Page 207: Micro Qr Code

    Micro qr code enter/exit programming mode product reference guide 197 micro qr code set length 2 this feature specifies one of the barcode lengths for micro qr code length control. Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode. Ch...

  • Page 208: Ucc Composite

    Enter/exit programming mode ucc composite 198 wdi4600 ucc composite ucc composite enable / disable enables/disables the ability of the reader to decode the stacked part of a ucc composite label. Default $ccmen00(cr) ucc composite = disable $ccmen01(cr) ucc composite = enable this feature is not effe...

  • Page 209: Ucc Optional Composite Timer

    Ucc composite product reference guide 199 ucc optional composite timer specifies the amount of time the system will wait for the stacked part of a ucc composite label before transmitting the linear label without an add-on. Default $ccmot00(cr) ucc optional composite timer = timer disabled $ccmot01(c...

  • Page 210: Postal Code Selection

    Postal code selection 200 wdi4600 postal code selection enables/disables the ability of the scanner to decode labels of a specific postal symbology. • disable all postal codes • australia post • postnet • japan post • planet • imb • royal mail • sweden post • kix • portugal post default $cpoen00(cr)...

  • Page 211: Postnet Bb Control

    Postal code selection product reference guide 201 postal code selection (continued) $cpoen06(cr) postal code selection = enable japan post $cpoen07(cr) postal code selection = enable imb $cpoen08(cr) postal code selection = enable sweden post $cpoen09(cr) postal code selection = enable portugal post...

  • Page 212: Notes

    Postal code selection 202 wdi4600 notes.

  • Page 213: Motion Features

    Product reference guide 203 motion features m otion a iming c ontrol on page 203 m otion s ensitivity on page 204 m otionless t imeout on page 204 use this chapter to configure motion settings for the handheld. Reference appendix b for a listing of standard factory settings. Motion aiming control co...

  • Page 214: Motion Sensitivity

    Enter/exit programming mode motion features 204 wdi4600 motion sensitivity defines discrete set of levels for scanner motion sensitivity when in handheld use. $cmosy00(cr) motion sensitivity = low $cmosy01(cr) motion sensitivity = medium default $cmosy02(cr) motion sensitivity = high motionless time...

  • Page 215: Chapter 4

    Product reference guide 205 chapter 4 references this section contains explanations and examples of selected barcode features. See "configuration using barcodes" starting on page 15 for the actual barcode labels used to configure the reader. Rs-232 p arameters starting on page 206 s ymbologies start...

  • Page 216: Rs-232 Parameters

    References 206 wdi4600 rs-232 parameters rs-232 baud rate baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly. Stop bits the stop bit(s)...

  • Page 217: Rs-232/usb Com Parameters

    Rs-232 parameters product reference guide 207 rs-232/usb com parameters intercharacter delay this parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A s...

  • Page 218

    References 208 wdi4600 ack nak options this enables/disables the ability of the reader to support the rs-232 ack/nak protocol. When configured, the reader and/or host sends an “ack” when it receives data properly, and sends “nak” when the data is in error. Options are: • disable • enable for label t...

  • Page 219

    Rs-232 parameters product reference guide 209 nak character this setting specifies an ascii character or hex value to be used as the nak character. Ascii characters or any hex value from 0 to 0xff can be selected. Setting to previously defined characters such as xon, xoff, or host commands conflicts...

  • Page 220

    References 210 wdi4600 ack nak timeout value this option specifies the amount of time the reader waits for an ack character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout...

  • Page 221

    Rs-232 parameters product reference guide 211 ack nak retry count this feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimite...

  • Page 222

    References 212 wdi4600 disable character specifies the value of the rs-232 host command used to disable the reader. Ascii characters or any hex value from 0 to 0xff can be selected. Setting to previously defined characters such as xon, xoff, or host com- mands conflicts with normal operation of thes...

  • Page 223

    Rs-232 parameters product reference guide 213 enable character specifies the value of the rs-232 host command used to enable the reader. Ascii characters or any hex value from 0 to 0xff can be selected. Setting to previously defined characters such as xon, xoff, or host com- mands conflicts with nor...

  • Page 224: Keyboard Interface

    References 214 wdi4600 keyboard interface wedge quiet interval specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments. This feature applies only to the keyboard we...

  • Page 225: Intercharacter Delay

    Keyboard interface product reference guide 215 intercharacter delay this parameter specifies the intercharacter de lay be tween the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies ...

  • Page 226: Intercode Delay

    References 216 wdi4600 intercode delay specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes ...

  • Page 227: Symbologies

    Symbologies product reference guide 217 symbologies set length length control allows you to select either variable length decoding or fixed length decoding for the specified symbology. Variable length: for variable length decoding, a minimum and maximum length may be set. Fixed length: for fixed len...

  • Page 228: Data Editing

    References 218 wdi4600 4. Scan the appropriate two digits from the keypad in appendix d, keypad that represent the length setting which was determined in the steps above. You will hear a two-beep indi- cation after the last character. If you make a mistake, before the last character scan the cancel ...

  • Page 229: Global Prefix/suffix

    Data editing product reference guide 219 please keep in mind... • modifying a message string is not a mandatory requirement. Data editing is a sophisti- cated feature allowing highly customizable output for advanced users. Factory default set- tings for data editing is typically set to none. • a pre...

  • Page 230: Global Aim Id

    References 220 wdi4600 global aim id this feature enables/disables addition of aim ids for all symbology types. Aim label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. Aim label identifiers consist of three char...

  • Page 231: Label Id

    Data editing product reference guide 221 label id a label id is a customizable code of up to three ascii characters (each can be one of hex 0x01- 0xff), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this optio...

  • Page 232

    References 222 wdi4600 databar 14 composite r4 523400 c 523400 databar expanded rx 525800 t 740000 databar expanded composite rx 525800 d 525800 databar limited rl 524c00 v 760000 databar limited composite rl 524c00 i 524c00 data matrix dm 446d00 w 770000 ean128 000000 k 6b0000 ean128 composite 0000...

  • Page 233

    Data editing product reference guide 223 msi @ 400000 z 5a0000 pdf417 p 500000 r 720000 plessey a 610000 a 610000 postal australian $k 244b00 $k 244b00 postal imb $v 245600 $v 245600 postal japanese $r 245200 $r 245200 postal kix $u 245500 $u 245500 postal planet $w 245700 $w 245700 postal portugal ...

  • Page 234

    References 224 wdi4600 label id: set individually per symbology to configure a label id individually for a single symbology: 1. Go to page 49 and scan the enter/exit barcode. 2. Select label id position as either before (enable as prefix) or after (enable as suf- fix) by scanning the appropriate bar...

  • Page 235

    Data editing product reference guide 225 table 36 step action examples 1. Scan the enter/exit barcode (scanner enters programming mode) 2. Determine placement of the label id characters before or after with regard to scanned data using "label id control" starting on page 49 enable as prefix enable a...

  • Page 236: Character Conversion

    References 226 wdi4600 character conversion character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ascii values. The first character in the pair is the character that will be converted. The second character in the pair is the charac...

  • Page 237: Reading Parameters

    Reading parameters product reference guide 227 reading parameters good read led duration this feature specifies the amount of time that the good read led remains on following a good read. The good read led on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seco...

  • Page 238: Scanning Features

    References 228 wdi4600 scanning features scan mode this mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader. The following selections are valid for all models: trigger single: when the trigger is pulled, scanning is activated until one of the fol...

  • Page 239: Stand Mode Off Time

    Scanning features product reference guide 229 stand mode off time this feature specifies the amount of time reader illumination stays off after pulling the trigger when in stand mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). Follow these instructions to ...

  • Page 240: Scanning Active Time

    References 230 wdi4600 scanning active time this setting specifies the amount of time that the reader stays in scan on state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired ...

  • Page 241: Aiming Duration Time

    Scanning features product reference guide 231 aiming duration time specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature:...

  • Page 242: Flash On Time

    References 232 wdi4600 flash on time this feature specifies the on time for the indicator led while in flash mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in...

  • Page 243: Flash Off Time

    Scanning features product reference guide 233 flash off time this feature specifies the off time for the indicator led while in flash mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determi...

  • Page 244

    References 234 wdi4600 multiple labels ordering by code symbology this feature specifies the transmission ordering by symbology type, when multiple labels per frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string to 12 characters if not using all six symbolog...

  • Page 245

    Scanning features product reference guide 235 table 44 hex value symbology id hex value symbology id 00 don't care 2c gtin5 01 upc-a 2d gtin8 02 upc-e 2e s2of5 03 ean8 2f pdf417 04 ean13 30 code11 05 upc2 31 iata 06 upc5 32 micro_pdf 07 c128_addon 33 gs1 databar_lim_id 0a ean128 34 gs1 databar_lim_c...

  • Page 246: Motion Features

    References 236 wdi4600 motion features motionless timeout this setting specifies the amount of time that the reader takes to assume that it is in a motionless condition. The range for this setting is from 500 msec to 25.5 seconds, in 100 millisecond increments. Follow these instructions to set this ...

  • Page 247: Appendix A

    Product reference guide 237 appendix a technical specifications table 46 contains physical and performance characteristics, user environment and regulatory information. Table 46 item description physical characteristics color black /yellow dimensions height 7.1”/181 mm length 3.9”/100 mm width 2.8”/...

  • Page 248

    Technical specifications 238 wdi4600 depth of field (typical) a symbology standard range (sr) models code 39 5mil: 1.6” -7.5” (4.0 -19cm) 10mil: 0.4” - 11.8” (1.0 - 30cm) 20mil: up to 17.7” (up to 45cm) ean 7.5mil: 0.5” - 10.6” (2.0 - 27cm) 13mil: 0.6” - 15.7” (1.5 - 40cm) pdf 417 6.6mil: 1.0” - 5.9...

  • Page 249

    Technical specifications product reference guide 239 decode capability 1d barcodes upc/ean/jan (a, e, 13, 8); upc/ean/jan (includ- ing p2 /p5); upc/ean/jan (including; isbn / bookland & issn); upc/ean coupons; code 39 (including full ascii); code 39 trioptic; code39 cip (french pharmaceutical); logm...

  • Page 250

    Item description user environment wdi4600 operating temperature 32° to 131° f (0° to 55° c) charging temperature n/a storage temperature -4° to 158° f (-20° to 70° c) humidity operating: 5% to 90% relative humidity, non-condensing drop specifications scanner withstands 18 drops from 1.8 meters (5.9 ...

  • Page 251: Imager Labeling

    Technical specifications product reference guide 241 imager labeling sample labels are shown for illustrative purposes only. Please view the labels on your product for actual details, as they may vary from those depicted. Scanner regulatory label.

  • Page 252: Standard Cable Pinouts

    Technical specifications 242 wdi4600 standard cable pinouts figure 10 , and table 47 provide standard pinout information for the interface cable. Figure 10. Standard cable pinouts: handheld pin 10 cable clip (latch) to host cable cable strain relief bottom of scanner interface cable port pin 1 table...

  • Page 253: Led and Beeper Indications

    Technical specifications product reference guide 243 led and beeper indications the reader’s beeper sounds and its led illuminates to indicate various functions or errors on the reader. An optional “green spot” also performs useful functions. The tables below list these indications. One exception to...

  • Page 254: Error Codes

    Technical specifications 244 wdi4600 table 49 programming mode - the following indications only occur when the reader is in programming mode. Label program- ming mode entry a valid programming label has been scanned. Led blinks continuously reader sounds four low fre- quency beeps. Label program- mi...

  • Page 255: Appendix B

    Product reference guide 245 appendix b standard defaults the most common configuration settings are listed in the “default” column of the table below. page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provi...

  • Page 256

    Standard defaults 246 wdi4600 disable character ‘d’ 30 enable character ‘e’ 30 keyboard wedge country mode u.S. Keyboard 32 send control characters 00 36 wedge quiet interval 100 ms 37 intercode delay no delay 37 caps lock state caps lock off 38 numlock numlock key unchanged 38 usb keyboard speed 1 ...

  • Page 257

    Standard defaults product reference guide 247 good read beep length 80 ms 62 good read beep volume high 63 good read led duration 300 ms 64 scanning features scan mode trigger single 65 stand mode indication disable 66 stand operation switch to stand mode 67 pick mode disable 68 stand mode sensitivi...

  • Page 258

    Standard defaults 248 wdi4600 code selection - 1d symbologies code ean/upc coupon control enable only upca coupon decoding 81 upc-a upc-a enable/disable enable 82 upc-a check character transmission send 82 expand upc-a to ean-13 don’t expand 83 upc-a number system character transmission transmit 83 ...

  • Page 259

    Standard defaults product reference guide 249 ean 8 check character transmission send 91 expand ean 8 to ean 13 disable 92 ean 8 2d component 2d component not required 92 upc/ean global settings upc/ean price weight check disable 93 upc/ean quiet zones two modules 94 add-ons optional add-ons disable...

  • Page 260

    Standard defaults 250 wdi4600 code 39 danish ppt enable/disable disable 110 code 39 laposte enable/disable disable 111 code 39 pzn enable/disable disable 111 code 128 code 128 enable/disable enable 112 expand code 128 to code 39 don’t expand 112 code 128 check character transmission don’t send 113 c...

  • Page 261

    Standard defaults product reference guide 251 interleaved 2 of 5 cip hr enable/disable disable 127 follett 2 of 5 follett 2 of 5 enable/disable disable 127 standard 2 of 5 standard 2 of 5 enable/disable disable 128 standard 2 of 5 check character calculation disable 128 standard 2 of 5 check charact...

  • Page 262

    Standard defaults 252 wdi4600 codabar set length 2 50 142 abc codabar disable 143 abc codabar abc codabar enable/disable disable 143 abc codabar concatenation mode static 143 abc codabar dynamic concatenation timeout 200 msec 144 abc codabar force concatenation disable 145 code 11 code 11 enable/dis...

  • Page 263

    Standard defaults product reference guide 253 gs1 databar™ limited 2d component 2d component not required 157 code 93 code 93 enable/disable disable 157 code 93 check character calculation enable check c and k 158 code 93 check character transmission enable 158 code 93 length control variable 159 co...

  • Page 264

    Standard defaults 254 wdi4600 aztec code length control variable 174 aztec code set length 1 1 175 china sensible code enable / disable disable 177 china sensible code length control variable 177 china sensible code set length 1 1 178 china sensible code set length 2 7,827 179 data matrix enable / d...

  • Page 265

    Standard defaults product reference guide 255 micro qr code enable/disable disable 195 micro qr code length control variable 195 micro qr code set length 1 0001 196 micro qr code set length 2 0035 197 ucc composite enable / disable disable 198 ucc optional composite timer timer disabled 199 postal c...

  • Page 266: Notes

    Standard defaults 256 wdi4600 notes.

  • Page 267: Appendix C

    Product reference guide 257 appendix c sample barcodes the sample barcodes in this appendix are typical representations for their symbology types. 1d barcodes upc-a ean-13 978033029095 code 39 code 128 code 128 interleaved 2 of 5.

  • Page 268: Sample Barcodes (Continued)

    Sample barcodes 258 wdi4600 sample barcodes (continued) code 32 codabar 13579 code 93 code 11 123456789.

  • Page 269: Gs1 Databar™ (Rss)

    Sample barcodes product reference guide 259 gs1 databar™ (rss) gs1 databar™ expanded stacked 10293847560192837465019283746029478450366523 gs1 databar™ expanded 1234890hjio9900mnb gs1 databar™ limited 08672345650916 gs1 databar™ variants must be enabled to read the barcodes below (see gs1 databar™ om...

  • Page 270: 2D Barcodes

    Sample barcodes 260 wdi4600 2d barcodes aztec datamatrix china sensible code maxicode pdf 417 abcabc micro pdf 417 bv17453 qr code 35900g9 micro qr code 123456 ucc composite.

  • Page 271: Appendix D

    Product reference guide 261 appendix d keypad use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad. 0 1 2 3 4 5 6 7 8 9.

  • Page 272

    Keypad 262 wdi4600 a b c d e f.

  • Page 273: Appendix E

    Product reference guide 263 appendix e scancode tables control character emulation control character emulation selects from different scancode tables as listed in this appendix. each of the control character sets below are detailed by interface type in the tables. these apply to wedge andÂ...

  • Page 274

    264 wdi4600 interface type pc at ps/2, usb-keyboard or usb-keyboard for apple table 51. Scancode set when control character is 00 or 01 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x null c+@ soh c(s)+a stx c(s)+b etx c(s)+c eot c(s)+d enq c(s)+e ack c(s)+f bel c(s)+g bs ht tab lf c(s)+j vt c(s)...

  • Page 275

    Product reference guide 265 interface type pc at ps/2, usb-keyboard or usb-keyboard for apple (continued) table 52. Scancode set when control character is 02 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x ar ↓ ar ↑ al ↓ al ↑ cl ↓ cl ↑ cr ↓ cr ↑ bs tab s+ tab enter keypd enter ins pg up 1x pg dwn...

  • Page 276

    266 wdi4600 interface type pc at ps/2 alt mode or usb-keyboard alt mode table 53. Scancode set when control character is 00 or 01 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x alt+000 alt+001 alt+002 alt+003 alt+004 alt+005 alt+006 alt+007 bs ht tab alt+010 alt+011 alt+012 cr enter alt+014 alt+...

  • Page 277

    Product reference guide 267 interface type pc at ps/2 alt mode or usb-keyboard alt mode (continued) table 54. Scancode set when control character is 02 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x ar ↓ ar ↑ al ↓ al ↑ cl ↓ cl ↑ cr ↓ cr ↑ bs tab s+ tab enter keypd enter ins pg up 1x pg dwn home ...

  • Page 278: Digital Interface

    268 wdi4600 digital interface table 55. Scancode set when control character is 00 or 01 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x null c+@ soh c(s)+a stx c(s)+b etx c(s)+c eot c+d enq c(s)+e ack c(s)+f bel c(s)+g bs ht tab lf c(s)+j vt c(s)+k ff c(s)+l cr enter so c(s)+n si c(s)+o 1x dle c(...

  • Page 279: Ibm31Xx 102-Key

    Product reference guide 269 ibm31xx 102-key table 57. Scancode set when control character is 00 or 01 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x null c+@ soh c(s)+a stx c(s)+b etx c(s)+c eot c+d enq c(s)+e ack c(s)+f bel c(s)+g bs ht tab lf c(s)+j vt c(s)+k ff c(s)+l cr enter so c(s)+n si c(...

  • Page 280: Ibm Xt

    270 wdi4600 ibm xt table 59. Scancode set when control character is 00 or 01 x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xa xb xc xd xe xf 0x null c+@ soh c(s)+a stx c(s)+b etx c(s)+c eot c+d enq c(s)+e ack c(s)+f bel c(s)+g bs c(s)+h ht tab lf c(s)+j vt c(s)+k ff c(s)+l cr enter so c(s)+n si c(s)+o 1x dle c(s)+p...

  • Page 281

    Scancode tables product reference guide 271 microsoft windows codepage 1252 windows-1252 is a character encoding of the latin alphabet, used by default in the legacy components of microsoft windows in english and some other western languages..

  • Page 282: Notes

    Scancode tables 272 wdi4600 notes.

  • Page 283: Ascii Chart

    Ascii chart ascii char. Hex no. Ascii char. Hex no. Ascii char. Hex no. Ascii char. Hex no. Nul soh stx etx eot enq ack bel bs ht lf vt ff cr so si dle dc1 dc2 dc3 dc4 nak syn etb can em sub esc fs gs rs us 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18 19 1a 1b 1c 1d 1e ...

  • Page 284

    Wasp barcode technologies 1400 10th street plano, texas usa 75074 www.Waspbarcode.Com 820033790 (rev. C) december 2013.