Watec WAT-902H2 ULTIMATE Operation Manuals
Danger
LEVEL
CLOSED
OPEN
Danger
Danger
Monochrome CCD Camera
WAT
WAT
WAT
WAT----902H
902H
902H
902H
2
2
2
2
ULTIMATE
ULTIMATE
ULTIMATE
ULTIMATE
WAT
WAT
WAT
WAT----902H
902H
902H
902H
3
3
3
3
ULTIMATE
ULTIMATE
ULTIMATE
ULTIMATE
Operation Manual
This Operation Manual covers safety, camera functions, installation and the
correct operating procedure for the WAT-902H
2/3
ULTIMATE. First, we ask you
to read this Operation Manual thoroughly, then install and operate the
WAT-902H
2/3
ULTIMATE as advised. In addition, for future reference, we also
advise safekeeping of this manual.
Please contact the distributor or dealer from which the WAT-902H
2/3
ULTIMATE
was purchased, if you do not understand the installation, operation or safety
instructions laid out in this manual. Not understanding the contents of the
Operation Manual sufficiently may cause damage to the camera.
Guide to the Safety Symbols
The definitions of the symbols used in this operation manual are:
When you do not adhere to or take notice of the “Danger” sign, it
may lead to a serious accident such as death or injury caused by
fire or electric shock.
When you do not adhere to or take notice of the “Warning” sign, it
may cause severe damage such as a physical injury.
When you do not adhere to or take notice of the “Caution” sign, it
may incur injury and cause damage to peripheral objects in the
immediate surroundings.
Cautions for Safety
WAT-902H
2/3
ULTIMATE is designed to be used safely; however, if not used
safely, it may lead to a physical accident caused by fire and electric shock.
Therefore, please keep and read the “Cautions for Safety” below for protection
against accidents.
•
Do not disassemble and/or modify the WAT-902H
2/3
ULTIMATE.
•
Do not operate the WAT-902H
2/3
ULTIMATE with wet hands.
•
Use only the AD901-120/230 or equivalent power adaptor for
the WAT-902H
2/3
ULTIMATE.
The recommended voltage is DC+12V
±
10%
•
Do not expose the WAT-902H
2/3
ULTIMATE to wetness or high
moisture conditions.
The WAT-902H
2/3
ULTIMATE is designed and approved for indoor
use only. The WAT-902H
2/3
ULTIMATE is not water-
resistant or waterproof. If the location of the camera is outdoors or
in an outdoor like environment, we recommend that you use an
outdoor camera housing.
•
Protect the WAT-902H
2/3
ULTIMATE from condensation.
Keep the WAT-902H
2/3
ULTIMATE dry at all times during storage
and operation.
•
Should the camera not work properly, switch off the power
immediately. Then check the camera according to the “Problems
and Trouble Shooting” section.
•
Avoid the striking of hard objects or dropping the WAT-
902H
2/3
ULTIMATE.
The WAT-902H
2/3
ULTIMATE uses high quality electrical parts
and precision components.
•
Do not connect any power supply directly to the video out
terminal of the unit.
Do not connect the WAT-902H
2/3
ULTIMATE with any monitor
using a video/power single transmission terminal. The WAT-
902H
2/3
ULTIMATE is not designed for use with this type of
equipment. We also advise you to read the operation manual of
the monitor you plan to use before any connections are made.
•
Do not install the WAT-902H
2/3
ULTIMATE in a position
subject to direct sunlight.
Sunlight shinning directly onto the WAT-902H
2/3
ULTIMATE lens
can cause damage to the CCD.
•
Select a stable place for installation of the WAT-902H
2/3
ULTIMATE.
Use a support of durable strength around an installation position
on a ceiling or wall when a camera stand or tripod is used.
•
Do not move the WAT-902H
2/3
ULTIMATE with the cables
connected.
Before moving the WAT-902H
2/3
ULTIMATE, always remove the
video cable and power cable from the rear of the camera first.
•
Avoid using the WAT-902H
2/3
ULTIMATE near any strong
electromagnetic field.
After installing into main equipment, if the WAT-902H
2/3
ULTIMATE is exposed to electromagnetic waves causing the
monitored image to become distorted, we recommend the camera
be shielded by appropriate protective casing.
Problems and Trouble Shooting
If any of the following problems occur when using the WAT-902H
2/3
ULTIMATE,
•
An optimal picture cannot be obtained, after checking that all the cables
and connections are correctly in place
•
Smoke or any unusual odor emerges from the WAT-902H
2/3
ULTIMATE.
•
An object becomes embedded or a quantity of liquid seeps into the camera
housing
•
More than the recommended voltage or/and amperage has been applied
to the WAT-902H
2/3
ULTIMATE by mistake
•
Anything unusual occurring to any equipment connected to the WAT-
902H
2/3
ULTIMATE.
Disconnect the camera immediately according to the following
procedures:
①
Switch off the main power supply to the camera.
②
Remove the power and video cables connected to the WAT-902H
2/3
ULTIMATE.
③
Contact the distributor or dealer from which the WAT-902H
2/3
ULTIMATE was
purchased.
About EMC
The WAT-902H
2/3
ULTIMATE is in conformity with EMC test standards carried
out by authorized organizations in Japan.
E I A
/
FCC Part15 class B
CCIR EN61000-6-3/EN50130-4
Do not modify the WAT-902H
2/3
ULTIMATE. A modified camera
may not conform to EMC test standards.
Contents
Using the contents figures below, check to make sure all parts are present before
use.
Lens Mount Cap
WAT-902H
2/3
ULTIMATE
DC plug
Iris connector
Description of Parts
①
CCD FRONT FACE
・
・
・
・
The light receiving face of the CCD camera
(Dirt, water or oil deposits on the CCD will cause an unclear picture on the
monitor. Attach the lens cap to protect the lens and CCD from contamination
and damage.)
②
LENS MOUNT
・
・
・
・
Mount for the lens (Thread type)
③
IRIS LEVEL VOLUME
・
By controlling the volume, the iris level of a DC iris lens can be adjusted.
④
FOCUSING ADJUSTMENT SCREWS
・
・
・
・
There are 3 hex. adjustment screws each placed at intervals of 120
゜
for fine
focusing of the lens.
⑤
AUTO-IRIS SOCKET
・
・
・
・
This socket is for a video or DC auto-iris lens cable connector.
(Video/DC: Auto selected by the camera)
⑥
TRIPOD MOUNTING SCREW HOLES
・
・
・
・
Mounting holes for stands. The size of these threads are 1/4”, 20 threads, 4.5
±
0.2mm, which is the same as any standard camera tripod (U1/4”).
⑦
CAMERA BASE
・
・
・
・
The camera base has a thread for fixing to a standard tripod and four M3 size
holes for additional easy fixing.
⑧
VIDEO OUT (BNC)
・
・
・
・
The terminal for composite video signal output
⑨
GAMMA CORRECTION SWITCH
・
・
・
・
Three gamma values are selectable, 1.0, 0.45, 0.35.
⑩
POWER IN
・
・
・
・
The terminal designed for the DC-plug of the power adaptor
⑪
MGC VOLUME ADJUSTING
・
The volume for setting manual gain control
⑫
AGC/MGC SELECTION SWITCH
・
Switch for setting AGC HI
、
LO or MGC
⑬
BACK LIGHT
・
・
・
・
The switch for back light compensation
⑭
ELECTRONIC SHUTTER ON/OFF SWITCH
・
・
・
・
The switch for the selecting electronic shutter mode
⑮
AE MODE CONTROL
・
・
・
・
The switch for the shutter speed mode control according to the object being
monitored
Power Supply
If any other power adaptor besides the AD901-120/230 is used, please use a
stabilized power adaptor designed for DC+12V
±
10%, with a current capacity of
more than 250mA.
Use the optional DC plug if the shape or polarity of the DC plug of the power
adaptor to be used is not compatible with the camera (See the drawing on the
right below).
The wiring on the connector must be exact.
Be careful not to touch the other terminal while wiring.
Protect the wiring portion by using insulation tape after
wiring. If the above care and attention is not adhered to,
damage to the WAT-902H
2/3
ULTIMATE
and power
adaptor may occur and may also cause fire.
Auto-iris Lens
Before connecting the auto-iris lens, please make sure that the pin configuration
is correct by confirming with the following table. If the configuration of your iris
connector is different from the following, the plug and pins will need to be
rewired.
Pin No.
EIAJ Video
Auto-iris Lens
Arrangement
EIAJ DC
Auto-iris Lens
Arrangement
①
Power
Control
-
②
Not used
Control
+
③
Iris signals
Drive
+
④
Common (GND)
Drive
-
Camera Base
There is a tripod mounting screw
hole as shown in the diagram on
the right .
In addition, there are 4 corners
holes M3 size and one
φ
5 for
stability.
Set-up and Operation
1)
Ensure that the power to the WAT-902H
2/3
ULTIMATE and the peripheral
equipment is turned off before making any connections.
2)
Remove the lens mount cap from the WAT-902H
2/3
ULTIMATE and attach the
CS-mount lens. Use the optional C-mount adaptor (30CMA-R) when a
C-mount lens is used.
3) Connect the iris control cable to
⑤
AUTO-IRIS SOCKET on the WAT-902H
2/3
ULTIMATE when an auto-iris lens is being used.
4) Connect
⑧
VIDEO OUT on the WAT-902H
2/3
ULTIMATE with the monitor,
using a coaxial cable with 75
Ω
impedance, such as an RG-58/U or an
RG-6/U. Select a monitor with the same television system as the
WAT-902H
2/3
ULTIMATE: EIA or CCIR. A monitor with more than 600TV lines
is recommended.
5) Insert the power plug of the power adaptor into
⑩
POWER IN on the back
panel of the WAT-902H
2/3
ULTIMATE. Confirm that the power adaptor is not
connected to the power supply before insertion of the power plug into
⑩
POWER IN.
6)
Turn on the power to the WAT-902H
2/3
ULTIMATE, monitor and all other allied
equipment. When a picture cannot be obtained on the monitor, or a problem
occurs, check and follow the procedure mentioned in the
【
Problems and
Trouble Shooting
】
section.
7)
After following the procedure below and the picture is still out of focus, open
the iris fully and loosen
④
FOCUSING ADJUSTMENT SCREWS with the hex.
wrench and move the lens forwards until a clear picture is obtained.
Manual Lens
Adjust the focus and iris to the best position on
the lens.
Video Auto-iris Lens
Adjust the focus on the lens.
DC Auto-iris Lens
Adjust the iris level on the camera, then adjust
the focus on the lens. See below.
Iris Level Adjustment (for DC auto-iris lenses only)
Adjust
③
IRIS LEVEL VOLUME placed on the side
of the unit until an acceptable light level is attained.
No change will occur if a video iris lens or manual
iris lens is fitted.
8)
Select any required gamma by the
⑨
GAMMA CORRECTION SWITCH.
Mode
Gamma
Effect
OFF
1.0
Required for image processing such as data
storage for PCs and for FA.
LO
0.45
Standard setting for using TVs and
Monitors. Natural images can be obtained
in dark areas.
HI
0.35
Dark areas can be lightened and bright
areas can be reduced.
※
Select LO position for normal use. In a low light environment or dark
viewing, HI mode is recommended.
※
The switch is set to LO(
γ≒
0.45) upon shipment.
9)
Select any required gain control by the
⑫
AGC/MGC SELECTION SWITCH.
Mode
Range
Effect
MGC
5 - 60dB
・
In a low light environment, when
illumination of the object is important,
increase the manual gain. Lower the gain
control for a clearer picture with less
noise. (Factory automation or Image
processing)
AGC HI
5 - 60dB
・
When minimum illumination is more
important than the S/N ratio
(Surveillance in a low light environment)
AGC LO
5 - 32dB
・
When SN ratio is more important than
minimum illumination.
・
When adequate lighting is present or a
stable lighting condition is available.
※
The switch is set to LO(5-32dB) upon shipment.
10)
Set the gain to any required environment by
⑪
MGC VOLUME ADJUSTING.
Manually adjusted in a range between 5 to 60dB. In a low light environment,
when illumination of the object is important, increase the manual gain.
Lower the gain control for a clearer picture with less noise.
※
The volume is set to L(Min.) upon shipment.
Warning
DC+12V
COMMON(GND)
Caution
Warning
Caution
①
②
③
④
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
Warning
Caution
Hex. Wrench