Water Filters Australia K-WFADUOGN Owner's Manual - page 7
CONNECT TO WATER SUPPLY
TheInstallationDiagramshowsanoverviewofthewater
supply connection including the Pressure Limiting Valve.
CONNECT DUAL FAUCET TO WATER SUPPLY (IF FILTER SYSTEM NOT INCLUDED)
• TakebluetubefromDualFaucetandinsertintothetubeconnectorattheendofthePLVDCasshown
inStep7.
• Pullbackonthetubetoensuretubeislockedintoposition.
• ConnectredlockingclipwhereshowninStep7.
• Tubingmustnotbekinkedortwisted.
• Tubingshouldbecuttoaconvenientlengthbutshouldnotbestretchedtaut.
• Ensureallfittingsandtubeconnectionsareprotectedagainstdamagefromobjectsstoredinthe
cupboard.
• The350kPapressure
limiting dual check
valve (PLVDC) must be
connected to the stop tap
as shown. Use plumbing
tape to create seal.
• Useplumbingtapeto
connect the ¼" mbsp
to ¼" tube pushfit
connector to the PLVDC
Stop tap for cold water
supply (not included)
¼” mbsp x ¼”
tube connector
Pressure Limiting
Dual Check
Valve 350kPa
Locking clip
INSTALL FILTER SYSTEM (IF INCLUDED) REFER INSTALLATION DIAGRAM
• Thefiltersystemshouldbeinstalledinaconvenientlocation.Pleaseallow40mmclearance
underneath the filter to facilitate filter replacement.
• Locatetheheadassemblyandaffixtokitchencupboardwithscrewsandbracketsupplied.
• Theheadassemblyhas'pushfit'fittingsontheinletandoutlet.Removetheredlockingclips.
• Takethelengthofbluetubingsuppliedandcuttosizetoconnectfromtheoutletofthefilterheadto
thePLVDC.MakesuretubeiscutsquareandcleanwithaStanleyknifeorsimilar.
• Takebluetubingfromthedualfaucetandinsertintheoutlet(righthandsideoffilterhead)offilter
head assembly. Push tubing in and then pull back to ensure a tight seal. Reconnect locking clip.
• Waterflowmustbeinthedirectionindicatedbythearrowonthetopofthefilterhead.
• Insertfiltercartridgeintofilterhead-twistcartridgeaquarterturnanticlockwiseuntilcartridge
locks firmly into filter head.
STEP 7
STEP 8
STEP 9