Water-Loo Portable Skid Toilet Operation Manual - page 8
8
TROUBLESHOOTING
Your Microflush toilet is designed to give you years of trouble-free operation. Please check the
following before beginning any service or repair.
Water Supply:
1. Is the water shut-off valve turned to “on” position?
Air System:
1. Is compressed air attached (on rail unit)?
2. Is air compressor turned on, fuse OK (solar unit)?
3. Is regulator set to 60-65 psi?
4. Do you have any air leaks or kinks in the air system?
5. Do you have water in the air system? This will cause irregular timing. Drain
the air reservoir and check filter regulator for water. To check for water in the
Air/Water Sequence Valve, remove bleed off plug, put finger over screw
opening and flush. If water is present, it will squirt from sides of valve body.
If water is detected, then air cylinder and airlines must also be drained.
Cycle Time:
1. Is bleed off plug blocked? Remove, clean and reinstall.
Trouble Possible
Cause
Correction
Flapper does not open.
Water does not flow.
Nothing happens.
1. No air supply to stool.
2. Water has accumulated in
Air/Water Sequence Valve
1. Connect air supply or turn on
compressor.
2. See “Air System” above
Flapper opens and closes 4-7
seconds after button is released,
but no water enters bowl.
1. No water in tank.
2. Water turned off.
1. Re-fill water tank
2. Open “shut-off” valve
Flapper opens when flushed and
closes immediately when button
is released.
Debris in check valve at base of
Air/Water Sequence Valve.
Clean Air/Water Sequence Valve
Flapper opens and will not close
Bleed-Off plug blocked
Remove, clean or replace,
reinstall
Water continues to run when
Microflush stool not in use.
1. “Flush” button stuck in down
position.
2. Foreign object is under water
valve in Air/Water Seq. Valve.
1. Remove, clean or replace,
reinstall flush button.
2. Clean Air/Water Sequence
Valve
Flush cycle is too long
Bleed-Off Plug blocked.
Remove, clean or replace,
reinstall.
Flush cycle is too short
Bleed-Off Plug missing or related
air lines leaking
Replace Bleed-Off plug and
check air lines for leaks
Battery Discharged
1. Cloudy weather conditions for
more than four days in a row
2. fuse blown on charge
controller
1. Re-Charge battery with battery
charger or position unit so that
solar panel faces sunlight
2. check for blown fuse on
charge controller, replace if
blown