OPERATING DISPLAYS AND INSTRUCTIONS:
1. GENERAL OPERATION:When the system is operating, one of five displays may be shown and will alternate with the
installing dealer’s name and phone number for future service. Pressing
NEXT
will alternate between the displays.
1.
CURRENT TIME OF DAY and GPM
2.
FLOW RATE which is the current treated water flow rate through the system in Gallons Per Minute
3.
VACATION MODE allows the system to be “shut down” when there will be no water usage for an extended
period of time
4. CAPACITY REMAINING which is the gallons that will be treated before the system signals a regeneration cycle
5.
DAYS TO A REGEN is the number of days left before the system goes through a regeneration cycle, based on
the days override value
6.
DEALER NAME AND PHONE NUMBER is the dealer information to call when service is needed (this screen will
only appear if set by dealer)
The user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at the preset time of regeneration, the words “REGEN
TODAY” will appear on the display.
If a water meter is installed, “GPM” flashes on the display when water is being treated, indicating gallons per
minute going through the system.
2. VACATION MODE:This feature may be used to “shut down” the system while on vacation. The manufacturer has
factory set “OFF” as the default. Turn feature “OFF” or “ON” using the
+ or — buttons. When turned “ON”, the
unit will not regenerate while there is no water usage. Once water usage is observed (minimum of 50 gallons), the
unit will automatically regenerate that night and resume normal operation.
CAUTION: Depending on the severity of water conditions and the length of no water
usage, it may not be recommended to use this feature. Please contact
dealer or manufacturer for more information.
3. REGENERATION MODE:Typically a system is set to regenerate at a time of no
water usage. If there is a demand for water when the system is regenerating, untreated
water will be delivered. When the system begins to regenerate, the display will include
information about the step of the regeneration process and the time remaining for that
step to be completed. The system runs through the steps automatically and will reset
itself to provide treated water when the regeneration has been completed.
4. MANUAL REGENERATION:Sometimes there is a need to regenerate before the control valve calls for it. This
may be needed if a period of heavy water use is anticipated or when the system has been operated without salt.
•
To initiate a manual regeneration at the next preset regeneration time, press and release
REGEN
. The
words “REGEN TODAY” will flash on the display to indicate that the system will regenerate at the next
regeneration time (set in Programming, steps 4 and 5). If you pressed the
REGEN
button in error, pressing the
button again will cancel the command.
•
To initiate a manual regeneration immediately, press and hold the
REGEN
button for three seconds. The
system will begin to regenerate immediately. This command cannot be cancelled.