Waterco Hydroxzone Ozone Generator Owner's Manual

Summary of Hydroxzone Ozone Generator

  • Page 1

    Www.Waterco.Com australian approval number: 13041001/00 hydroxzone ozone generator owner’s manual.

  • Page 2: General Safety Rules

    General safety rules 1. The equipment mentioned in this manual is specially designed for the sanitizing of water in swimming pools. 2. It is designed to work with clean water at a temperature not exceeding 60°c (140°f). 3. The installation should be carried out in accordance to the safety instructio...

  • Page 3: Save These Instructions

    Important safety instructions read and follow all safety instructions read and be familiar with this manual before installing or operating your new hydroxzone ozone generator. • voltage must be determined before unit is installed. • do not bury cord. • connect only to a properly grounded, grounding ...

  • Page 4

    Table of 1. Hydroxzone ozone generator ---------------------------- 01 2. Installation ----------------------------------------------------- 03 3. Hydroxzone maintenance/hours ------------------------ 09 4. Troubleshooting guide ------------------------------------- 09 5. Technical specifications --...

  • Page 5: 1.1 Introduction to Ozone

    1. Hydroxzone ozone generator 1.1 introduction to ozone the hydroxzone ozone generator system produces ozone when air is drawn across a special high-energy vacuum ultraviolet (vuv) lamp, converting some air to ozone and hydroxyl radicals. A dynamic venturi is inserted on the return line, by-passing ...

  • Page 6

    1.2 the dynamic venturi injector (dvi) assembly hydroxzone ozone generator uses a dynamic venturi injector that enhances the transfer of ozone to the water. The injector is specially designed to minimise the pressure drop across the system. Figure 1.2 how the injector works figure 1.3 venturi inject...

  • Page 7

    I pg 03 hydroxzone ozone generator 2. Installation 2.1 preparing for installation i. Check for and correct all leaks in plumbing. Ii. Balance the pool water iii. Backwash the filter on retrofit installation. Iv. Shock the pool. Hydroxzone must be used in combination with and approved/registered sani...

  • Page 8: (Water Balance)

    2.3 install the saddle clamps (bypass) 1. Turn pump off. 2. Locate section of existing plumbing in which you choose to install the entrance leg of the bypass. Location should be in any accessible area after the pump, but before the filter (please refer to figure 1.1). 3. Install saddle clamp top & b...

  • Page 9

    I pg 05 hydroxzone ozone generator note: for 50mm pipe, do not use 40 mm adapters and gasket and turn bushings so small end points toward injector (for entrance) or pvc pipe (for exit). Figure 2.2 saddle clamp assembly at bypass entrance figure 2.3 saddle clamp assembly at bypass exit venturi inject...

  • Page 10

    2.5 install hydroxzone supply tube 2.5.1. The hydroxzone unit is supplied with sufficient braided supply tube which may be cut to length. Ensure sufficient slack in the supply tube. Do not extend the length of the braided supply tube. 2.5.2. For installations where the hydroxzone unit is installed 4...

  • Page 11

    I pg 07 hydroxzone ozone generator 2.5.4. Connect the polybraided hose to the barb on the side of the hydroxzone ozone generator. (see figure 2.6). 2.5.5. For flooded installations or where the hydroxzone is installed below 400mm above the highest point of the filter system, two (2) check valves and...

  • Page 12: 2.6 Electrical Installation

    2.6 electrical installation hydroxzone ozone generator is designed to operate on either 120 or 240 vac, 50/60 hz. Connect thehydroxzone ozone generator either to the circulation pump switch or timer. Hydroxzone ozone generator unit and circulation pump should be started simultaneously. Refer to nati...

  • Page 13

    I pg 09 hydroxzone ozone generator 3. Hydroxzone maintenance the hydroxzone ozone generator is rated to last 20,000 hours of continuous operation. Start up and shut down cycles should be kept to a minimum to extend the life of the lamp. The u/v lamp within the hydroxzone will provide up to 80% of th...

  • Page 14

    5. Technical specifications 6. Spare parts list 7. Warranty power input (volts) 120 - 277 frequency (hz) 50/60 degree of protection ipx4 max. Current (a) 8 temperature operating range (°c) -32 to 60 dimension (mm) 425 x 160 x 90 part number description 60137201 check valve 1/4” 60137203 1/4” hose ba...

  • Page 15

    I pg 11 hydroxzone ozone generator.

  • Page 16

    Waterco limited abn 62 002 070 733 (zzb1460) 11/2014 offices - australia nsw - sydney (head office) tel: +61 2 9898 8600 qld - brisbane tel: +61 7 3299 9900 vic/tas - melbourne tel: +61 3 9764 1211 wa - perth tel: +61 8 9273 1900 sa/nt - adelaide tel: +61 8 8244 6000 act distribution tel: +61 2 6280...