WaterFurnace TPCM32U03 Instruction Manual - page 7
7
INSTRUCTION GUIDE: ElITE COmmUNICaTING ThERmOSTaT
IG1602EW 06/12
Faults
Non-Critical Faults
Non-critical faults are displayed
below the temperature on the main
screen. These faults will clear
themselves if the fault condition
corrects itself. Your dealer should
be informed when either a critical or
non-critical fault occurs.
Lockout/Critical Faults
Critical faults will change the screen
to the service needed screen
and turn the backlight color to
red. The system can be reset by
pressing the left arrow key on the
thermostat. Some of the faults
will clear themselves if the fault
condition corrects itself. Your dealer
should be informed when either a
critical or non-critical fault occurs.
Fault Reference
Fault Code
Fault Description
1
Inputs Error (O and W)
2
high Pressure
3
low Pressure
4
Freeze Detection (FP2)
5
Freeze Detection (FP1)
7
Condensate Overflow
8
Over/Under Voltage
9
air Flow/RPm
10
Compressor monitor
11
FP1 or FP2 Sensor Error
15
hot Water limit
18
Non Critical Communication Error
19
Critical Communication Error
NOTE: For a complete list of fault codes, please reference the
unit’s manual.
1/5/12 12:40 PM
FAN AUTO
76°
OFF
E18-NCRITCOMM ERROR
HUMIDITY
34%
REL HUM
MODE FAN MENU
SERVICE
NEEDED
PHONE CONTRACTOR
CONTRACTORS NAME
HERE
555-555-5555
MODEL NUMBER
MODEL HERE
SERIAL NUMBER
0000000000
E2 –HIGH PRESSURE
◄ RESET TRIP
Events Per Day
This is where you can set the number of events per day. (an
event is a period of time scheduled with a certain heating and
cooling setpoint.) For instance if you are away from your home
from 8am to 5pm, make this period of time an event and set
the thermostat at an energy saving setting. You have the option
of setting the events per day to 4-RESIDENTIal (4 events),
2-RESIDENTIal (2 events) or 2-BUSINESS (2 events).
Smart Heat Staging (Heat Pump Only)
This delays 3rd stage heating for a set
time. Options are ON or OFF. Default is
OFF. Range for this are 0-120 minutes in 5
minute increments. If set to ON, 30 minutes
is the default time.( If ‘ON’ is selected and
the demand has not been satisfied the
thermostat will energize electric heat after the selected time has
expired regardless of demand.)
Cooling Lockout
When an outdoor temperature sensor is installed, it can be set
up so cooling option doesn’t energize if the outdoor temperature
is below a certain temperature. Ranges for this are NONE
(default), 45˚F, 50˚F, or 55˚F.
Electric Heat Or Dual Fuel Lockout
When an outdoor temperature sensor is installed, you can set it
up so the electric heat or Dual Fuel option doesn’t energize if the
outdoor temperature is above a certain temperature. Ranges for
this are NONE (default), 5˚F to 60˚F in 5˚ increments.
Compressor Satisfy
Normal – allows compressor downstaging from Y2 to Y1.
Recommended setting for most products.
Y2 Finish – Once the heat pump has engaged Y2 the thermostat
will not allow downstaging to Y1. The call is satisfied
in Y2.
Remote Sensor
allows selection of the remote sensor to determine indoor
temperature. Options are REmOTE SENSOR, aVERaGE, and
STaND alONE. The REmOTE SENSOR is connected to the ID
and GND on the thermostat terminals.
4-Residential
(Default)
2-Residential
2-Business