Step 8S – Set Gallons Capacity using the or
∆
button. If value is set to:
• “AUTO” ...the gallon capacity will be automatically calculated and reserve capacity will be
automatically estimated.
• “oFF”...the regeneration will be based on the day override set
(see Installer Settings Step 3I).
• a specific number (allowable range 20 to 50,000)...the regeneration initiation will be based
on the value specified. The settable increment is 20 for the range 20 to 1000, 50 for the
range of 1000 to 10,000 and 100 for the range of 10,000 to 50,000.
If “oFF” or a specific number is used, hardness display will not be allowed to be set in
Installer Displays Step 2I. Press NEXT to go to Step 9S.
Press REGEN if you need to return to the previous step.
Step 9S – Set Regeneration Time Options using the or
∆
button. If value is set to:
• “NORMAL”...the regeneration will occur at the preset time.
• “on O”...the regeneration will occur immediately when the gallons capacity reaches 0
(zero).
• “NORMAL + on 0”...the regeneration will occur at one of the following:
— the preset time when the gallons capacity falls below the reserve or the specified
number of days between regenerations is reached whichever comes first; or,
— immediately after 10 minutes of no water usage when the gallon capacity reaches 0
(zero).
Press NEXT to go to Step 10S. Press REGEN if you need to return to the previous step.
Step 10S – Set Low Salt Warning using the or
∆
button. If the value is set to:
• “oFF”...no low salt level warning will appear for the user.
• a specific value...“FILL SALT” will flash on the display when
the calculated remaining pounds of salt falls below that level.
Allowable values range form 10 to 400 pounds in 10 pound
increments.
Press NEXT to exit SOFTENER SYSTEM SETUP.
Press REGEN if you ned to return to the previous step.
STEP 8S
ß
STEP 9S
ß
STEP 10S
ß
RETURN TO
NORMAL MODE
SOFTENER SYSTEM SETUP