    Wl270 operating, installation, and service manual waterlogic commercial products, llc 11710 stonegate circle omaha, ne 68164 (800) 288-1891 www.Waterlogic.Us.

  • Page 2

    Wl270 operating, installation, and service manual congratulations on your choice of the waterlogic wl270water treatment system. The wl270 model dispenses cold, ambient and hot. Every wl270 includes: bio-cote® anti-microbial protection advanced in-tank ultraviolet (uv) purification the waterlogic wl2...

  • Page 3

    Wl270 features and benefits cold, ambient, and hot water the wl270 unit comes standard with ambient, cold and hot selections to meet a wide range of customer demands. Cold water temperature is adjustable. High volume storage and water capacity the wl270 unit has 4 liters of cold water capacity, 1.6 ...

  • Page 4

    Wl270 certifications waterlogic water treatment systems have been tested, and certified to rigorous nsf and ul standards. We believe that performance testing and certifications validate waterlogic as a world- leader in water treatment systems. Wl270 certifications include ul399 – certified drinking ...

  • Page 5

    Introduction carefully read and follow all instructions to ensure proper and efficient operation of your wl270. Contact waterlogic or an authorized waterlogic dealer if you have any questions. Waterlogic and authorized waterlogic dealers employ trained service personnel who are experienced in the in...

  • Page 6

    Safety precautions basic safety precautions should be followed, including the following: danger! If incorrectly installed, operated or maintained, this product can cause death or severe injury. Those who install, operate, or maintain this product should be trained in its proper use, warned of its da...

  • Page 7

    Model/part designations brand name description model - part number wl270 waterlogic wl270 – cold, ambient and hot 19-gu-sb f-1001-fs-hca-ut-bs-inn specifications item wl270 water connection ¼” quick connect cold water temperature cold water temperature – factory set point 41° - 5°c (adjustable) 34° ...

  • Page 8

    Operating instructions the above picture shows front lcd display and control panel for the waterlogic wl270. For cold water: press green cold water select button for ambient water: press glue ambient water select button for hot water: press both hold the hot safety button (right hand side) while hol...

  • Page 9

    Wl270 water flow diagram wl270 operating, installation, and service manual page 9 - revision: 4-7-2015.

  • Page 10

    Pre-installation procedures danger! Electrical shock hazard. Only qualified personnel who have read and understand this entire manual should attempt to install, or service this unit, failure to do so could result in death or serious injury. Do not plug into an electrical supply until specifically in...

  • Page 11

    3. Completely remove the plastic internal reservoir from the wl270. 3a. Remove and discard the clear silicon float protector from the electronic float. 3b. Loosen the water supply line fitting from the mechanical float. 3c. Disconnect the white plastic electrical connectors attached externally to th...

  • Page 12

    Caution! Filter flush required. Wl270’sare not supplied with filters. Filters should be configured to optimize your system. Filters need to be configured and specified to do the job given the local water conditions, usage, maintenance schedule, and placement restrictions. In order for our filters to...

  • Page 13

    Red compressor/heater switch must be in the o=off position while the hot tank is empty. Damage could occur within one minute and the overload (high limit) will require manual reset if heater is turned on with an empty hot tank. 9. Turn on the water and plug the wl270 into a power source. Verify the ...

  • Page 14

    17. Turn off the red compressor / heater switch. Unplug the unit. Switch off the cold and hot drain caps on the back of the unit. Drain the wl270, replace drain caps. Red compressor/heater switch must be in the o=off position. 18. Reconnect the uv wiring connectors. 19. With the red compressor / hea...

  • Page 15

    25. After the cold and hot water temperatures have been reached, turn the red heater/compressor switch off. Red heater and compressor power switch must be in the o=off position while the hot tank is empty. Damage could occur within one minute and the overload (high limit) will require manual reset i...

  • Page 16

    Wl270 draining instructions drain the wl270 for transportation. Warning! Store unit empty . Always sanitize before reuse. The unit must be completely drained and sealed before storing to avoid stagnation and reduce microbial growth). Prior to draining the hot tank, turn off the red heater and compre...

  • Page 17

    Installation procedures safety and installation guidelines ensure all local, state, and federal laws and codes including health and safety guidelines are met when installing waterlogic equipment. Only qualified service technicians should attempt installation and service of waterlogic equipment. Warn...

  • Page 18

    1. Attach the water supply line to the 1/4” feed water hose adaptor fitting on the back of the unit. Waterlogic requires the use of a water pressure regulator. Water feed pressure must be between 40-60 psi. Turn on the water supply and check for leaks. 2. Check to ensure that the red heater and comp...

  • Page 19

    12. Once the unit is at the target temperature(s), sample the water to ensure water meets expectations and additional rinsing or adjustment is not required. 13. Check the unit for any leaks. External leak protection is always recommended. Wl270 operating, installation, and service manual page 19 - r...

  • Page 20

    Service requirements warning! Read and understand the contents of this manual before attempting to service wl270. Failure to follow the instructions in this manual could result in death, serious personal injury, or severe property damage. Only trained and qualified technicians should attempt to inst...

  • Page 21

    Replacement components component part no. Frequency of replacement quartz sleeve for 8 watt lamp ct-2002 clean 12 months, or as required wlusa part no 10-1400 uv lamp assembly, 8 watt ct-2083 every 12 months wlusa part no 10-2350 replacement parts can be obtained from waterlogic or an authorized wat...

  • Page 22

    Hot tank descaling instructions the hot tank requires removal of mineral deposits (descaling) on a regular basis. Typically descaling should take place every 6 to 12 months to preserve the long-term health of your unit. Use non-toxic cleaner such as scalekleen, dezcal, 20% citric acid solution, or u...

  • Page 23

    6. When unit has finished draining, replace hot tank drain cap. 7. Remove reservoir from unit. 8. Mix descaler per instructions. 9. Add descaling mixture to the hot tank through the hot tank fill portal located in the water inlet port. 10. Replace reservoir. 11. Turn on water supply and plug in unit...

  • Page 24

    Resetting the overload or high limit safety 1. Turn off red heater and compressor power switch on rear of unit. 2. Unplug the power cord from rear of unit. 3. Remove the lower front panel of unit by removing the phillips head screws underneath the lower front panel. 4. Locate the protective metal bo...

  • Page 25

    6. Press the reset button 7. Reattach the metal box by depressing the top flap of the metal box so it snaps back into its original position on the hot tank. 8. Replace the lower front panel on unit using phillips head screws. 9. Plug in the power cord. 10 make sure the hot and cold tanks are filled ...

  • Page 26

    Wl270 layout drawing with part numbers no part no description wlusa part no. 1 pl-1254 top charcoal cover 19-5005 2 pl-1259 reservoir cover with biocote® 19-1038 3 st-8212 side panel – silver 19-1019 4 pl-1255 upper silver insert panel for drip tray with biocote® 19-1034 5 pl-1257 front hatch charco...

  • Page 27

    10 pl-1292 leak tray 19-1049 11 st-8229 front bottom bracket 19-1021 12 st-8035 down base 12-1602 13 co-9001-a compressor (r134a 1/8 hp) 110v / 60hz 10-2200 not shown co-9008 filter dryer 12-1001 14 pu-4100-c leak detection floats 19-1005 st-8232 leak level sensor bracket 19-1025 16 pu-4025 2” filte...

  • Page 28

    Wl270 hot and cold tank assembly print and parts list no part no description wlusa part no. 1 pl-1128 uv lamp retaining threaded nut 12-1210 2 ct-2083 uv lamp 8 w 10-2350 3 ct-2006 quartz sleeve o-ring 10-2500 4 ct-2002 quartz sleeve 10-1400 5 pu-1049 silicon seal – gf water inlet port to tanks bioc...

  • Page 29

    Wl270 faucet and front hatch assembly drawing and parts list no part no description wlusa part no. 1 lp-7180 led cover label 19-1014 2 pl-1257 black front insert panel 19-5010 3 pl-1264 ambient pushbutton faucet with biocote® 19-1042 4 pl-1263 cold pushbutton faucet with biocote® 19-1041 5 pl-1262 h...

  • Page 30

    Wl270 reservoir assembly drawing and parts list no part no description wlusa part no. 1 pl-1290 air filter silicone cap biocote® 19-1076 2 pl-4108 carbon air filter 19-1052 3 pl-1259 reservoir cover 19-1038 4 pu-4099 reservoir cover seal biocote® 19-1056 5 pl-1258 plastic reservoir storage tank 19-1...

  • Page 31

    Wl270 electrical diagram danger! High voltage electrical hazard. Pcb (printed circuit board) contains high voltage. Only trained and qualified technicians should attempt live testing. Wl270 operating, installation, and service manual page 31 - revision: 4-7-2015.

  • Page 32

    Troubleshooting water leaks possible reason solution water leak most leaks will be detected by the internal wl270 leak detection system that will trigger or turn off the inlet solenoid valve. Isolate the supply and start normal fault finding procedures. Wl270 operating, installation, and service man...

  • Page 33

    Troubleshooting low flow of cold water or hot water or both possible reason solution water pressure verify that the water pressure is at the recommended 40 to 60 psi for wl270 to operate properly. Check with pressure regulator. Filter or membrane blockage verify that the ro filters or membrane are n...

  • Page 34

    Troubleshooting bad or plastic taste possible reason solution reservoir not flushed properly if the unit is new, it may need flushing for a longer time. Wl270 operating, installation, and service manual page 34 - revision: 4-7-2015.

  • Page 35

    Troubleshooting hot water is not hot (185° +/- 5° f) note: the wl270 does not have sleep or power saving mode and the hot water should be a minimum of 185°f under normal operating conditions. The hot temperature set point is 185° f and is controlled by a thermostat on the side of the tank. There is ...

  • Page 36

    Troubleshooting restricted flow of hot water possible reason solution partially closed water supply valve to the unit. Open water supply valve. Hot tank outlet hole is scaled over. Remove outlet tube from hot tank to faucet. Add descaler to hot tank. Tubing is creased or has a “kink” in it. Inspect ...

  • Page 37

    Troubleshooting hot water flows, cold water does not flow. Possible reason solution cold tank frozen disconnect power supply for one house to allow tank to defrost. Flush the cold water system. Check that the cold thermostat settings are correct cold water temperature – factory set point 41° - 5°c (...

  • Page 38

    Troubleshooting cold water flows, hot water does not flow. Possible reason solution no hot water verify the pipes feeding the hot water tank. Check that the mechanical water outlet faucet valve is operating and the water flows through it. Wl270 operating, installation, and service manual page 38 - r...

  • Page 39

    Troubleshooting water is not being heated or chilled possible reason solution red heater and compressor switch on unit is off. Turn red heater and compressor switch on. I = on wl270 operating, installation, and service manual page 39 - revision: 4-7-2015.

  • Page 40

    Troubleshooting no cold or hot water will dispense from unit possible reason solution closed water supply valve open the water supply valve. The unit is not properly plugged into electrical outlet check electrical outlet connection, or for blown circuit breaker. Red heater and compressor button on u...

  • Page 41

    Troubleshooting compressor runs but does not chill possible reason solution condenser is dirty clean the condensing coil of any obstructions or dust. Reduction of airflow into unit. Make sure unit is not under minimum ventilation requirements (2 to 4 inches). Compressor is running very hot. Low or l...

  • Page 42

    Troubleshooting compressor is not running possible reason solution red heater and compressor power switch button on unit is in the off position turn red heater and compressor power switch on. I = on compressor starting circuit turn red heater and compressor power switch off. O = off. Remove the comp...

  • Page 43

    Troubleshooting small amount of water periodically dispenses from faucet automatically possible reason solution obstruction in solenoid housing is preventing proper sealing of component. Drain unit according to drain instructions in this manual. Remove reservoir tank open faucet housing and check fo...

  • Page 44

    Troubleshooting no power possible reason solution no power supplied verify the building electrical supply to the wl270 unit is on. Verify the power cord is plugged in. Verify the power indicator light is on. Test the fuse. Start normal electrical fault finding procedures using the electrical diagram...

  • Page 45

    Troubleshooting dispense buttons stick possible reason solution dirt or foreign material is filling the gap around the push-buttons. Inspect the push buttons and clean surrounding area. Inspect faucet assembly inside the unit and clean as necessary. Wl270 operating, installation, and service manual ...

  • Page 46

    Waterlogic manufactured water treatment system limited warranty united states and canada only waterlogic water treatment systems are guaranteed to the original purchaser to be free of defects in materials and workmanship for a period of three (3) years from the date of purchase, but in no event long...