WaterLogic WL380 User Manual - page 2
WL380 User Manual
Page 5 ‐ Revision: 6‐9‐2016
WARNING!
DO NOT OPERATE IF DAMAGED. Unplug if abnormal case occurs. Contact Waterlogic or
authorized dealer for repair, service, and installation to avoid hazards.
WARNING!
HOT WATER. Unit produces Hot Water in excess of 188
o
F. Water above 125
o
F can
cause severe burns or scalding. Keep unauthorized people and children away from the unit to avoid
accidental dispensing of hot water.
WARNING!
CONNECT TO POTABLE WATER SUPPLY. This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality without
adequate disinfection. System is designed for the supplemental bactericidal treatment of public drinking
water, or other drinking water, which has been tested and deemed acceptable for human consumption
by the state or local health agency having jurisdiction. The system is designed to reduce normally
occurring non‐pathogenic or nuisance microorganisms only. System is not intended for treatment of
contaminated water.
WARNING!
TIP HAZARD. Dispenser could tip or fall causing serious injury. Always install unit on a
firm, flat, and level surface and secure the WL380 Water Treatment System to the base cabinet with the
screw provided to lock the components together. Secure unit to cabinet, wall, or floor if needed. Never
place heavy items on top of unit and never climb, stand, or hang on unit or storage cabinet to prevent
injury and damage.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED. Transport unit empty and always use
material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Sanitize before use to eliminate any
potential microbiological contaminates
CAUTION!
INDOOR USE ONLY. Intended for household use only.Never expose to direct sunlight,
heat sources, or ambient air temperature above 100°F (37°C) or below 35°F (2°C). Install indoors and
keep unit away from excessive humidity. Never expose to freezing temperatures. Ensure there is
adequate clearance around the unit to allow refrigeration system condenser to dissipate heat. Warmer
environments require more clearance around the unit. Minimum clearance around all surfaces of the
machine is 2‐inches. Installs where the ambient temperature exceeds 80°F, require a minimum of 4‐
inches clearance for proper heat dissipation and efficient operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 40 psi to 60 psi. Be aware
of any potential pressure surges caused by building/municipal pumping stations. Water block devices
and external leak detectors are strongly recommended. Locate the unit as close to the water supply and
the electrical connections as possible to minimize risk.
CAUTION!
USE PROPER SUPPLY LINES AND FEED WITH POTABLE AMBIENT WATER ONLY.
Feed water over 100° F (37°C) many damage the treatment components. Always use supply lines with
adequate pressure rating and UV resistance. Close water supply valve and contact service
representative if a leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.