Max retries – This is the maximum number of times (between 0 and 4) that the WM44 will attempt to
apply power to the pump socket after an interruption to water-flow is detected. The factory default
for this setting is 2.
6.4.1
Turning Pump Protection ON/OFF
Step
Action
Display
1
Press MENU and use ▼button to scroll to the "Pump" menu.
2
Press ENTER and the "PUMP" menu will be displayed with the
cursor highlighting either "Protect (ON)" or "Protect (OFF)".
3
Pressing ENTER multiple times will cycle between "Protect (ON)"
and "Protect (OFF)". When "Protect (ON)" is displayed, the factory
pre-set values for pump protection will be displayed.
Either press MENU twice to return to the home screen to leave the
default settings or continue to step 4 to adjust these settings.
4
Use the ▼button to scroll to "Max dry run (mins)" and press
ENTER. This value can be altered between 1 and 9 minutes using
the ▲ and ▼buttons and then press ENTER to save.
5
Use the ▼
button to scroll to "Retry after (mins)" and press ENTER.
This value can be altered between 5 and 30 minutes using the ▲
and ▼buttons and then press ENTER to save.
6
Use the ▼button to scroll to "Max retries" and press ENTER. This
value can be altered between 0 and 4 using the ▲ and ▼buttons
and then press ENTER to save. Pump protection set up is now
complete. Press MENU twice to return to the home screen.
6.5
Statistics Menu
The statistics menu provides useful technical information to the manufacturer and/or service personnel. This
menu is a read-only menu and there are no user adjustable settings.
Statistics Menu
1. Press MENU.
2. Use the ▼button to scroll to "Statistics".
3. Press ENTER.
4. Press MENU twice to return to the home screen.