3. Set the power switch to ON and verify that the Power LED is lit. If it is not, check the following:
The power switch is in the ON position.
The power cord is properly connected to the wall outlet and to the power connection on the switch.
The wall outlet is functional.
Note: Network cable segments can be connected or disconnected from the switch while the power is on, without
interrupting the operation of the switch.
3.3 Module
Installation
Warning: Before installing the modules into the QS3200, you must disconnect the switch from the main power
supply.
Handling the Modules
The module can be easily damaged by electrostatic discharge. To prevent damage, please observe the following:
Do not remove modules from their packaging until you are ready to install it into a switch.
Do not touch any of the pins, connections or components on the modules.
Handle the modules only by its edges and front panel.
Always wear an anti-static wristband connected to a suitable grounding point.
Always store or transport modules in appropriate anti-static packaging.
Module Setup and Installation
1. Ensure that the switch is disconnected from the main power supply and that you are wearing an anti-static
wristband connected to a suitable grounding point.
2. Place the switch on a flat surface.
3. Using a small cross-bladed screwdriver, remove the blank module plate from the front of the switch. Do not
remove any other screws from the switch.
4. Keep the blanking plate and screws in a safe place. If you remove the module at any time, you must replace the
blanking plate to prevent dust and debris from entering the switch and to aid the circulation of cooling air.
5. Hold the module so that the text on the front panel is oriented correctly, and insert it into the switch, ensuring the
connectors are fully engaged. Tighten the two captive thumbscrews that secure the module in place.
Figure 3 - Inserting the module
3.4
Connecting the Modules
Connecting the 10/100Base-TX Modules
1. Insert the RJ-45 connector on your cable into the socket of the module.
2. Connect the other end of the cable to an appropriate device with a 100Mbps Fast Ethernet or 10Mbps Ethernet
twisted pair interface.
3. Power up the switch.