10. Slideboilerintochassiscompartmentandpressfirmlytoensureboiler
isproperlyplaced(fig.E).Topreventpersonalinjuryorproperty
damage,theboilermustbefullyengagedpriortostart-up.
11. Plugpowercordintoaproperlyrated,groundedoutlet.
12. Press“Start”buttonatbaseofboiler(fig.E).“Start”buttonwillillum-
inatewhenheating;however,thelightwillgooutandboilerwillstop
heatingifelectricalpowerisinterruptedorstopped.Ifthisoccurs,
press“Start”buttonagaintorestartthedistillationcycle.
NOTE:Thecoolingfanwillnotstartimmediatelybecauseofa
delayedfanstart-upfeature.Thefanwillstartoncetheboilerhas
reachedapredeterminedtemperature,approximately30to40minutes
afterstartingthecycle.
WARNING:Topreventpersonalinjury,burnand/orscaldinjury,
DO NOT removeboilerwhile“Start”buttonisilluminatedoratanytime
whentheboilerishot.AlwaysunplugDistillerfromwalloutletandallow
boilertocoolcompletelybeforeremovingitfromtheDistiller(atleast30
minutes).
DO NOTchange
positionorlocationofDis-
tillerwhileitisoperatingor
cooling.
13. Placepreparedcarbon
filtercupintoopening
atthetopofthecollec-
tor/dispenserbottle.
DO NOTinstallcap
ontobottle(fig.F).
14. Replacethecollector/
dispenserbottle
(fig.F).Makesurethe
dispensingvalveis
securelytightened.
Waterwise 9000 Distiller Use & Care Guide
7
Figure E
Start
Button
Boiler
Boiler
Boiler Cap
Spout
Maximum Fill Point
(bottom of tabs)
Steam Baffle Securing Nut
Steam Baffle (flat side)
O-ring
Flange
Gasket
Figure D
Boiler Cap
Gasket
Distiller
Chassis