Watkins Caldera Spa Vacanza Series Owner's Manual - Spa Lock
lOCk FEATURES
The locking features, TEMPERATURE LOCK and SPA LOCK, are enabled from the control panel by a specific combination of buttons. Once enabled, a lock will remain
active until the specific button combination is applied to disable the lock. Even if power is disconnected from the spa and soon thereafter reapplied (such as a power
outage), the lock will remain in place.
SPA lOCk
To activate the Spa Lock feature, press “SET” button. When the “SET” icon flashes push “
TEMP t” button. Do not press any other buttons on the control panel
until the “SET” icon stops flashing. The
SLOC symbol is displayed and the “SET” icon will stop flashing. To deactivate the Spa Lock, press “SET” button. When
the “SET” icon flashes press the “
TEMP t” button. Do not press any other buttons on the control panel until the “SET” icon stops flashing. The SLOC symbol is
no longer illuminated and the “SET” icon will stop flashing .
TEMPERATURE lOCk
To activate the Temperature Lock feature, press “SET” button. When the “SET” icon flashes push “
TEMP s” button. Do not press any other buttons on the
control panel until the “SET” icon stops flashing. The
TLOC symbol is displayed and the “SET” icon will stop flashing. To deactivate the Temperature Lock, press
“SET” button. When the “SET” icon flashes press the “
TEMP s” button. Do not press any other buttons on the control panel until the “SET” icon stops flashing.
The
TLOC symbol is no longer illuminated and the “SET” icon will stop flashing .
FIlTER CYClES
When the spa is first powered up, the automatic filter cycle will wait 10 minutes before starting. Your spa will automatically turn the first filter cycle on for
60 minutes on low speed. The second filter cycle will activate for 30 minutes, 12 hours later. The filter cycle icon, F1 or F2, will be displayed on the
control panel.
NOTE: The optional Monarch
®
or PureWater ozone systems only work during the filter cycles.
To modify the length of either filter cycle:
A. Press and hold the “SET” button for approximately three seconds (The filtration icon will flash during programming).
B. Press the “LIGHT” button to select Filter Cycle 1 or 2 (a F1 or F2 will flash in the display). NOTE: Each filter cycle can be set independently.
C. Using the "
TEMP s" or the "TEMP t" button, adjust the length of filtering time desired (0 to 6 hours).
D. Programming will then be saved 10 seconds after the last button is pushed.
The filter cycle will activate the low speed of the jet pump for the entire cycle. When activated, the filter cycle icon on the display is turned on. If the temperature exceeds
the set point by three degrees F for more than three hours, the system will suspend the FILTER cycle and the filter cycle icon will blink for the remaining filter cycle time.
Should the temperature cool down to 1.5º F (1º C) within the set point before the end of the cycle, the cycle will resume for the rest of the time. Should you use the spa
during the filter cycle by placing the jet pump on high speed, the filter cycle icon will blink. Once the jet pump has been shut off, a ten minute tranquil mode begins (filter
cycle icon will be blinking during tranquil mode) before the filter cycle will resume. The blinking filter cycle icon indicates that the filter cycle timer is still counting, but the
cycle has been temporarily interrupted.
NOTE: When power is lost to the spa, both the temperature setting and filter cycle, revert to the previous setting.
OPERATION NOTE: For proper water-circulation during filtration cycles, rotate the air control valves counterclockwise to the off position.
MANUAl ClEAN CYClE
The clean-up cycle operates in the following manner: Jet pump 1 runs for ten minutes on high speed.
This system is initiated by pressing the “SET” button, then “JETS” button. The Filter and Jets icon will flash.
SlEEP MOdE
The Sleep Mode operation is a feature that minimizes pump operation during evening hours. For example, if Filter Cycle 1(F1) is set to activate at
8:00am, by default, Filter Cycle 2 (F2) will be set to activate at 8:00pm (12 hrs. later). During 8:00pm to 8:00am, if the spa should call for heat, the
pump and heater will activate to heat the spa. However, when in Sleep Mode, should the spa call for heat,
the pump and heater will be suspended
until the activation of Filter Cycle 1 at 8:00am, to minimize pump activation during evening hours.
NOTE: If water temperature drops below 80º F (26.7º C), pump and
heater will automatically activate to prevent temperature from dropping further.
To activate the Sleep Mode feature, press and hold “
TEMP s” and “TEMP t” buttons together for three seconds. This will activate the feature and override the normal
filter cycle operation. When these buttons have been engaged, the Sleep Mode icon will illuminate on the control panel display, indicating the feature is active. To
deactivate this feature, simply press and hold the specific buttons in the same manner once again.
AIR CONTROl
The Air Control(s) located next to your spa-side control panel allows you to change the power of the jets by regulating the amount of air that is mixed with the water
coming out of the jets.