Watts Premier HT-5-VOC-B Installation, Operation And Maintenance Manual

Summary of HT-5-VOC-B

  • Page 1

    Page 1 installation, operation and maintenance manual warning please read carefully before proceeding with installation. Failure to follow attached instructions or operating parameters may lead to the product’s failure. ********************************************************************************...

  • Page 2

    Page 2 thank you for your purchase of a state of the art reverse osmosis (ro) water treatment system. Water quality concerns are becoming more of a focus for the public. You may have heard about contaminants in the drinking water, such as arsenic, chromium, cryptosporidium or giardia. There may also...

  • Page 3: Table of Contents

    Page 3 ** before installation, please take a moment to fill out the warranty card on page 17. Table of contents operational parameters ................................................................................................................... 4 contents of reverse osmosis system ...............

  • Page 4: Operational Parameters

    Page 4 do not use with water that is micro biologically unsafe or of unknown quality without adequate disinfection before or after the system. System is intended to be installed on the cold water line only. If any of the items are missing please contact watts prior to installing. Contents of reverse...

  • Page 5

    Page 5 plumbing diagram and parts list 1 faucet 116118 2 polishing filter 100004 3 storage tank 119019 4 tank ball valve 134039 5 power transformer 152018 6 filter housing bowl 113013 7 adapt-a-valve 560080 8 booster pump 152012 9 tee fitting 125063 10 elbow qc 1/4” 125089 11 1/4 x 1/4 conn 125041 1...

  • Page 6

    Page 6 after drilling, remove all sharp edges and make sure the surroundings of the sink are cooled before mounting the faucet. Step 3 step 4 determine desired location for the ro faucet on your sink and place a piece of masking tape over where the hole is to be drilled. Mark the center of the hole ...

  • Page 7: Adapt-A-Valve Installation

    Page 7 turn off the cold water supply to the faucet by turning the angle stop valve completely off. Open cold water sink faucet to relieve pressure. Step 9 step 10 choosing the configuration that fits your plumbing, attach the adapt-a-valve as illustrated in the four photos above. Adapt-a-valve inst...

  • Page 8: Drain Saddle Installation

    Page 8 drain saddle fits standard 1 ¼” – 1 ½” drain pipes drain saddle installation step 11 step 12 step 13 the drain saddle must be mounted at least 1 ½” above the nut of the p-trap or cross bar from the garbage disposal to insure proper drainage. Assemble the drain saddle around the drain pipe at ...

  • Page 9: Tank Ball Valve Installation

    Page 9 thread the plastic ball valve onto the tank fitting. Do not apply teflon tape to fitting. Do not over tighten or the valve could crack. Step 20 tank ball valve installation green tube connection step 17 insert the other open end of the green 1/4” tube into the open 1/4” quick connect fitting ...

  • Page 10: Congratulations!

    Page 10 congratulations! You have completed the installation of your new reverse osmosis system. Please follow the startup instructions. Flushing of the tank 3 times is only necessary during the initial startup and after replacing the membrane. Note: start up instructions step 1 turn on the cold wat...

  • Page 11: 6 Month System Maintenance

    Page 11 how to remove / install filter housings when performing a filter change be sure to follow all of the steps. To remove: 1. Push housing up and twist to the left important: 2 1 2. Pull downward to install: 1. Push housing into the threaded housing cap. 1 2 2. Twist housing to the right until s...

  • Page 12: Annual Maintenance

    Page 12 items needed: annual maintenance √ stage 1 - sediment filter (part #: 104017) √ stage 2 - carbon block filter (part #: 101009) √ stage 4 - carbon voc (part #: 101013) √ stage 5 - final in-line filter (part #: 100004) remove the final filter from the two clips. Remove the fittings from both e...

  • Page 13: Membrane Replacement

    Page 13 membrane replacement use a 5/8” wrench to remove the white tube fitting on the left side of the horizontal membrane housing (end with one elbow). Step 1 step 2 step 3 step 4 step 5 this reverse osmosis system contains a replaceable component (the ro membrane) which is critical to the efficie...

  • Page 14: To Restart System:

    Page 14 california proposition 65 warning warning: this product contains chemicals known to the state of california to cause cancer and birth defects or other reproductive harm. (installer: california law requires that this warning be given to the consumer). For more information: www. Wattsind.Com/p...

  • Page 15: Performance Data Sheet

    Page 15 recommended replacement parts and change intervals: depending on incoming feed water conditions replacement time frame may vary. Change time description 6 months: sediment pre-filter (104017) carbon pre-filter (101009) 12 months voc carbon block (101013) final carbon filter (100010) 3 to 5 y...

  • Page 16

    Page 16 substance percent reduction influent challenge concentration (mg/l unless noted) maximum permissible product water concentration alachlor >98% 0.05 0.001 atrazine >97% 0.1 0.003 benzene >99% 0.081 0.001 bromodichloromethane (tthm) >99.8% 0.300 +/- 0.30 0.015 bromoform (tthm) >99.8% 0.300 +/-...

  • Page 17: 4 Ways to Register

    Page 17 4 ways to register 1. Online at www.Wattspremier.Com 2. Call in your information 1-800-752-5582 3. Fax in your information 623-866-5666 first name:_________________________ last name:____________________________ address: ________________________________________ city: ____________________ sta...

  • Page 18: Warranty Registration

    Page 18 warranty registration please fill out and keep for your records insert into envelope and return to watts premier first name:_________________________ last name:____________________________ address: ________________________________________ city: ____________________ state/prov:_______________...

  • Page 19: Service Record

    Page 19 service record date of purchase:__________ date of install:___________ installed by:__________________ notes: date 1st stage sediment (6 months) 2 nd stage carbon (6 months) 4th stage voc (1 year) final filter carbon (1 year) tfm membrane (2-5 years).

  • Page 20: Limited Warranty

    Page 20 limited warranty what your warranty covers: if any part of your watts reverse osmosis system is defective in workmanship (excluding replaceable filters and membranes), return unit after obtaining a return authorization (see below), less tank, within 1 year of original retail purchase, watts ...