Watts Premier WP-4V Installation, Operation And Maintenance Manual - page 19
Page 19
Description
Replace
Sediment Filter
Part# 104017
6 Months
Carbon Filter
Part# 101009
6 Months
Depending upon incoming feed water conditions replacement time
frame may vary.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of the indicated substances in water
enter
ed in NSF/ANSI 58. This
system has been tested for the treatment of water containing pentavalent arsenic (also known as As (V), As (+5), or arsenate) at concentrations of 0.30 mg/L or
less. This system reduces pentavalent arsenic, but may not remove other forms of arsenic. This system is to be used on water supplies containing a detectable free
chlorine residual at the system inlet or on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufficient to ensure complete conversion of trivalent arsenic to pentavalent arsenic, Please see the Arsenic Facts section of the Performance Data
Sheet for further information.
Avg. In.
Avg. Eff.
% Reduction pH
Pressure
Max Eff.
Inf. challenge
Max Allowable
(mg/L)
(mg/L)
mg/L
concentration
concentration
mg/L
mg/L
Arsenic (Pentavalent)
334.62 ug/L
5.039 ug/L
98.4%
50psi
19 ug/L
0.30±10%
0.010 mg/L
Barium Reduction
10.2
0.13
98.7%
7.24
50psi
0.27
10.0±10%
2.0
Cadmium Reduction
0.031
0.0001
99.7%
7.49
50psi
0.0009
0.03±10%
0005
Chromium (Hexavalent)
0.30
0.006
98.0%
7.24
50psi
0.013
0.03±10%
0.1
Chromium (Trivalent)
0.30
0.003
99.0%
7.24
50psi
0.008
0.03±10%
0.1
Copper Reduction
3.0
0.04
98.7%
7.64
50psi
0.06
3.0±10%
1.3
Cysts
222,077#/ml
10 #/ml
99.99%
50psi
58 minimum 50,000/mL
N/A
Fluoride Reduction
8.0
0.33
95.9%
7.49
50psi
0.47
8.0±10%
1.5
Lead Reduction
0.15
0.004
97.3%
7.49
50psi
0.008
0.15±10%
0.0107
Perchlorate
0.10
0.003
96.5%
7.39
50 psi
0.005 mg/L
0.10±10%
0.006
Radium 226/228
25pCi/L
5pCi/L
80.0%
7.24
50psi
5pCi/L
25pCiL±10%
5pCiL
Selenium
0.10
<0.001
99.0%
50psi
<0.001
0.10±10%
0.05
TDS
765
24
96.8%
7.84
50psi
39.0
750±40mg/L
187
Turbidity
81 NTU
0.15 NTU
99.8%
50psi
0.28 NTU
11±1 NTU
0.5 NTU
*Refer to the VOC Performance Data Sheet for the complete list of VOC’s.
Recovery - 15.5%
Daily Production Rate - 9.06 GPD
Efficiency - 8.35%
Depending on water chemistry, water temperature, and water pressure Watts Premier’s R.O. Systems production and performance will vary.
Efficiency rating means the percentage of the influent water to the system that is available to the user as reverse osmosis treated water under
operating conditions that approximate typical daily usage. Recovery rating means the percentage of the influent water to the membrane portion of
the system that
tank is bypassed. There is an average of 4 gallons of reject water for every 1 gallon of product water produced.
REFER TO OWNER’S INSTALLATION/SERVICE MANUAL FOR FURTHER MAINTENANCE REQUIREMENTS AND WARRANTY
INFORMATION.
Phone: (623) 931-1977
Fax: (623) 931-0191
Email: wpmail@wattsind.com
GENERAL USE CONDITIONS:
1. S
. DO NOT use with water that
is microbiologically unsafe or unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
2. Operating Temperature:
Maximum: 100°F (40.5°C)
Minimum: 40° (4.4°)
3. Operating Water Pressure:
Maximum: 85 psi (6.0kg/cm2)
Minimum: 40 psi (2.8kg/cm2)
4. pH
2 to 11
5. No iron present in incoming feed water supply.
6. Hardness of more than 10 grains per gallon (170 ppm) may reduce RO membrane life expectancy.
7. Recommend TDS (Total Dissolved Solids) not to exceed 1800 ppm.
Performance Data Sheet
WP-4v
Watts Premier Inc.
1725 W. Williams Drive C-20
Phoenix, AZ 85027 USA
Description
Replace
Stage 4 - VOC Block Filter
Part# 101013
12 Months
(600 Gallons)
RO Membrane
25 GPD Part# 110009
2 to 5 Years