Gather and identify the faucet pieces.
Remove faucet base & faucet spout from their respective
plastic bags. From above the sink, feed the faucet tubing &
toggle bolt down through the 1¼” mounting hole in the sink.
Ensure that the soft rubber gasket is uniformly positioned in
between the base and the top of the sink.
Align the faucet base so that the handle is on the right side and
the base is sitting flush on the sink top. Turn the handle down
(towards you) to the “ON” position to reveal the tightening
screw (located where the spout will be inserted). Using a
phillips head screwdriver, turn the screw clockwise until the
toggle bolt secures the faucet base snug onto the sink top,
do not over torque toggle bolt (5lb.in. max)
Once the faucet base is securely fastened to the sink top,
insert the faucet spout into the faucet base until it is fully
seated. Turn the handle up (away from you) to the “OFF”
position.
Completion of faucet installation (tubing connections) will be
done later in this manual. Refer to the
Black Tube Connection
(page 10), Red Tube Connection (page 11), and Blue Tube
Connection (page 11) sections of this manual.
Remove the faucet battery from the plastic bag. Locate the faucet battery compartment drawer on the base of the faucet.
Using a small screwdriver to pry on the notch at the compartment drawer face, slide the drawer out. Insert the battery into
the battery compartment drawer.
NOTE: The + side of the battery faces up. The compartment drawer will not slide in if the battery is installed upside
down.
Once the battery is in place, slide the battery compartment drawer back into the base until it is flush.
When the battery is first installed, both the red and green lights will flash to indicate that both lights are functional. Thereafter,
it will flash green only when the faucet handle is turned to the “ON” position. When your system is ready to be serviced
(approximately six months) you will see the light flash red when the handle is turned to the “ON” position. Refer to the
Six
Month Maintenance (page 12) section of this manual for filter replacement.
NOTE: If your water usage is high the red light may activate sooner than six months indicating the need for filter
replacement.
This faucet provides an electronic monitor that will tell you when it is time to replace the filters in your water
treatment device. The light indicator will be green for the life of the filter, turning red once the life of the filter has
been reached. This can occur after six months of use, or sooner for heavy water usage. To reset the electronic
monitor during replacement of filters, simply slide out the battery from the faucet and reinsert. The battery life is
expected to last one year, however, for heavy use the battery may need to be replaced sooner. For replacement,
look for battery number CR2354 (Watts p/n:116082) which is available at your local battery store or contact Watts
Premier at 800-752-7782. You can also order online at www.wattspremier.com.
WATTS Premier Chrome Monitor
(Top Mount) Faucet Installation
Step 6
Step 7
Step 8
Step 9
Step 10
Faucet Battery Installation
Minimum
Maximum
Mounting Hole Size
1.00”
1.25”
Torque on Toggle Bolt 5lb.in. (max)