Hardness:
Recommended hardness should not exceed 10 grains per gallon, or 170 ppm. System
will operate with hardness over 10 grains but the membrane life may be shortened. (Addition of a
water softener may lengthen the membrane life.)
1 Tank – White
1 Module – White
1 Parts Bag
1 Faucet Bag
1 Filter Wrench
If any of the items are missing please contact
Watts Premier prior to installing.
Tools Recommended For Installation
√
1 1/4" Hole Saw Bit for Faucet opening and/or
√
Round Knock out Punch for Stainless Sinks 1 ¼”
√
Adjustable Wrench
√
Sharp Knife
√
1 / 2" - 13/16” Open End Wrenches
√
Phillips Screw Driver
√
Needle Nose Pliers – Adjustable Pliers
√
Electric Drill
√
1/8", 1/4" & 3/8" Drill Bits
Contents of Reverse Osmosis (RO) System
Copper Tubing:
Reverse Osmosis water should not be run through copper tubing as the purity of the
water will leach copper and cause an objectionable taste in water and may cause damage to copper
tubing. Watts Premier supplies specialty filters that can be used if copper tubing is down stream of the
RO. Be sure to follow any state or local regulations.
Operational Parameters
Water Pressure:
The operating water pressure in your home should be tested over a 24 hour period
to attain the maximum pressure. If the incoming water pressure is above 85 psi a pressure regulator
is recommended and if over 100 psi then a pressure regulator is required. Should you need a gauge
to check your water pressure, see page 23 (item no. 261003).
1 Manual
Operating Temperatures:
Maximum 100°F (37.8°C)
Minimum 40°F (4.4°C)
Operating Pressure:
Maximum 85 psi (6.0 kg/cm
2
)
Minimum 40 psi (2.80 kg/cm
2
)
pH Parameters:
Maximum 11
Minimum 2
Iron:
Maximum 0.2 ppm
TDS (Total Dissolved Solids)
Turbidity
* All Filters Are Pre-Installed
Installation must comply with state and local plumbing regulations.
This system is intended to be installed on the cold water line only.