Weather-Rite UHA100 Installation, Operation & Service Manual - Warning
UHA L
OW
P
ROFILE
U
NIT
H
EATER
I
NSTALLATION
O
PERATION AND
S
ERVICE
M
ANUAL
48 of 51
15.9.1 Fan Removal and Replacement
15.9.2 To Replace the Fan Assembly
To replace the fan assembly, reverse the procedure
shown above.
• Check that the fan blades are free to rotate
before turning on the power to the fan.
• Strictly comply with the color code of the fan
wires to ensure correct operation. See Page 25,
Section 10.3 wiring diagram.
• Use onlygenuinereplacement parts sold and
supplied by Weather-Rite LLC.
15.10 Limit Switches
15.10.1 Removal and Replacement
1. Remove the electrical connections to the
switch.
2. Unscrew the two screws securing the
switch.
3. Fit a new switch with two screws.
4. Reconnect the electrical connections and test
operation.
Description
Part Number Quantity
Axial Fan UHA[X][S] 30
12011910
1
Axial Fan UHA[X][S] 45
12011911
1
Axial Fan UHA[X][S] 60
12011920
1
Axial Fan UHA[X][S] 75
12011921
1
Axial Fan UHA[X][S] 100 and UHA[X][S] 125
12011922
1
WARNING
Severe Injury Hazard
Turn off gas and electrical supply before
service.
Fan can start automatically at any time.
Failure to follow these instructions can