Webasto Air Top 3500 ST D Installation Instructions Manual - page 11
11
Renault Master/Nissan Interstar
On vehicles with side trim:
The dimensions 40 mm and 60 mm are
specifications for a side panel that reaches
down to the floor panel.
Should a side panel be installed that does not
reach down to the floor panel, these
dimensions must be calculated in accordance
with the distance to the floor panel.
Cut out side trim as shown
Cutting out
side trim
Mount side trim. Push preassembled hot air
ducting A/B with 80/55 reducer onto
distributor 1.
Drill 2.5 mm hole through reducer and
distributor. Connect reducer and distributor
with self-tapping screw.
Preassem-
bling distri-
bution
All vehicles
Shorten connection piece from air outlet by
approx. 10 mm on vehicles without side trim.
Mount cover piece 2 on air outlet 3. Mount air
outlet 3 with cover piece 2 on each hot air
elbow. Drill 2 2.5 mm dia. holes 1 each
through reducer and distributor. Connect
reducer and distributor with self-tapping
screw.
Installing
air outlet
When drilling, watch components located
behind!
Copy hole pattern 1 from cover piece 3 to side
panel or trim in each case.
Copy hole pattern 2 from air outlet 4 to cover
piece 3 in each case.
1 2.5 mm dia. hole, self-tapping screw
[4x each]
2 2.5 mm dia. hole, self-tapping screw
[3x each]
Installing
air outlet
19
780
80
80
320
90
30
90
80
40
*
60
*
1
20
A/B
1
3
21
1
2
1
1
22
1
3
1
2
2
2
4