Webasto Air Top 3500 ST Installation Instructions Manual - page 25
Technical Data
Unless tolerances are shown within the technical data
table, a tolerance of
±
10% applies at an ambient tempera-
ture of +20°C and at the rated voltage and conditions.
Electrical Components:
Control unit, motor, fuel metering pump, light bulb in the
digital timer* and pencil-type glow plug/flame detector are
designed either for 12-volt or 24-volt operation.
The digital timer*, temperature limiter and temperature sen-
sor are voltage-independent components.
* Presetting of heater operating times is not possible for
TRS-operation
Fuel for AT 3500/5000 B (Petrol):
The fuel specified by the vehicle manufacturer is suitable
as fuel for the heater.
Fuel for AT 3500/5000 D (Diesel/Fuel Oil EL):
The Diesel fuel specified by the vehicle manufacturer is
suitable as fuel for the heater. Also EL class fuel oil – not,
however, L type fuel oil – can be used provided it conform-
s to the usual quality on the German market in accordance
with DIN 51603.
Any negative effect caused by additives is not known.
When the fuel for the heater
is drawn from the vehicle’s fuel tank, the vehicle manufac-
turer’s specifications concerning additives are to be ob-
served.
When to changing to cold-resistant fuels, the heater must
be operated for approx. 15 minutes to ensure that the fuel
pump is filled with the new fuel.
Heater
Operation
Air Top
3500 B
Air Top
3500 D
Air Top
3500 D
Volume
Plus
Air Top
5000 B
Air Top
5000 D
Mark of approval
~S 305
~S 306
~S 306
~S 304
~S 303
Type
air heater with vaporizing type burner
Heat output
control range 1,5 – 3,5 kW
1,5 – 3,5 kW
1,5 – 5,0(5,5)* kW
*booster setting for max.
30 min.
Fuel
petrol
Diesel
petrol
Diesel
Fuel consumption
*booster setting for max. 30 min.
control range
0,17 – 0,46
l/h
0,17 – 0,42 l/h
0,19 – 0,66
l/h
(0,73)* l/h
0,17 – 0,60
l/h
(0,66)* l/h
Rated voltage
12 volts
12/24 volts
12 volts
12/24 volts
Operating voltage range
10,5 – 15
volts
10,5–15/21–30 volts
10,5 – 15
volts
10,5–15/21–30
volts
Rated power consumption
control range
15 – 36 W
15 – 36 W
15 – 90 W
15 – 90 W
15 – 90 W
Permissible ambient temperature:
Heater:
- operation
- storage
Metering pump- operation
- storage
Heater control - operation
- storage
-40°... +40°C
-40°... +85°C
-40°... +20°C
-40°... +85°C
-40°... +75°C
-40°... +85°C
Perm. combustion air intake
temperature
-40°... +20°C
Setting range for interior
temperature
+10 ... + 45 °C
Flow rate of heating air against
0.5 mbar
139 m3/h
139 m3/h
218 m3/h
218 m3/h
218 m3/h
CO2 content in exhaust gas
(permissible operating range)
1,5 kW
:5,0-8,0%
3,5 kW
:9,0-12,5%
1,5 kW
:5,0-8,0%
5 kW
:9,0-12,5%
Dimensions of heater
length 42
5
±
2 mm
width 148
±
1 mm
height148
±
1 mm
Weight of heater
5,9 Kg
Air Top 3500/5000
23
Visit www.butlertechnik.com for more technical information & downloads.