Weber Summit 675 NG General Information Manual

Other manuals for Summit 675 NG: Operating Manual
Manual is about: Weber SUMMITTM 4 BURNER & 6 BURNER NATURAL GAS COOKING MODULES Operating Guide

Summary of Summit 675 NG

  • Page 1

    Summit 475 & 675 natural gas barbecues summit 475 ng summit 675 ng this gas appliance is designed for outdoor use only. G eneral i nformation built-in construction general information warning a weber-stephen products co. Insulated sleeve must be used for any built-in installation. Clearance from com...

  • Page 2: Built-In Structure

    2 built-in structure cutout dimensions side 475 675 burner tolerances a 31 5 ⁄ 8 ” 43 5 ⁄ 8 ” 10 3 ⁄ 4 ” b 21 1 ⁄ 8 ” 21 1 ⁄ 8 ” 4 1 ⁄ 2 ” c 25” 25” 24” wt 240 285 40 dimensions + 3 ⁄ 16 ” - 0 + 3 ⁄ 32 ” - 0 + 3 ⁄ 16 ” -0 built-in cutout dimensions built-in structure sleeve dimensions a b c .625 typ...

  • Page 3: Built-In Sleeve Gas

    3 built-in sleeve gas line locations a b c support tubes front of sleeve front of sleeve plan view right side view 475 675 tolerances a 5.0” 5.0” b 10.1” 10.1” c 2.5” 2.5” dimensions + 1 ⁄ 16 - 1 ⁄ 16 + 1 ⁄ 16 - 1 ⁄ 16 + 1 ⁄ 32 - 1 ⁄ 32 built-in sleeve gas line locations the dimensions shown indicat...

  • Page 4: Typical Gas Supply

    4 typical gas supply installation gas line piping ■ if the length of line required does not exceed 50 feet, use a 5/8" o.D. Tube. One size larger should be used for lengths greater than 50 feet. ■ gas piping may be copper tubing, type k or l; polyethylene plastic tube, with a minimum wall thickness ...

  • Page 5

    5 built-in side burner for summit natural gas cooking modules this accessory may be purchased seperately. G eneral i nformation built-in construction general information warning a weber-stephen products co. Insulated sleeve must be used for any built-in installation. Clearance from combustible surfa...

  • Page 6: Built-In Structure

    6 built-in structure cutout dimensions side burner tolerances a 10 3 ⁄ 4 ” b 4 1 ⁄ 2 ” c 24” wt 40 dimensions + 3 ⁄ 16 ” - 0 + 3 ⁄ 32 ” - 0 + 3 ⁄ 16 ” -0 built-in cutout dimensions built-in structure sleeve dimensions side burner tolerances a 10 19 ⁄ 32 ” b 4 9 ⁄ 64 ” c 23 25 ⁄ 32 ” wt 40 dimensions...

  • Page 7

    7 built-in construction general information warning a weber-stephen products co. Factory installed sleeve must be used for any built-in installation. Clearance from combustible surfaces or structures warning: clearance from the outside walls of the sides and back of the sleeve must be a minimum of 2...

  • Page 8: Typical Gas Supply

    8 typical gas supply installation ■ a manual shut-off valve must be installed outdoors, and be accessible, not in the “built-in” structure. An additional manual shut-off valve indoors should be installed in the branch fuel line in an accessible location near the supply line. Caution: if young childr...