WebGate C1080PT-Z20 User Manual - page 23
23
MOTION SETUP > ALARM INPUT SETUP
OSD -
1
2
3
4
MOTION SETUP>
====================================================
POWER UP ACTION
JOG MAX SPEED
JOG DIRECTION
ALARM INPUT SETUP>
PARKING ACTION SETUP>
BACK
EXIT
ON
9O/SEC
NORMAL
‘
and press the ‘NEAR’ Key
ALARM INPUT SETUP>
====================================================
ALARM 1
ALARM 2
ALARM 3
ALARM 4
ALARM 5
ALARM 6
ALARM 7
ALARM 8
BACK
EXIT
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
N.O
ALARM INPUT SETUP>
====================================================
ALARM 1
ALARM 2
ALARM 3
ALARM 4
ALARM 5
ALARM 6
ALARM 7
ALARM 8
BACK
EXIT
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
ALARM INPUT SETUP>
====================================================
ALARM 1
ALARM 2
ALARM 3
ALARM 4
ALARM 5
ALARM 6
ALARM 7
ALARM 8
BACK
EXIT
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
N.C
N.O
N.O
N.O
N.O
N.O
N.O
N.O
Select ‘Alarm Number’
by move the joystick up/down.
And press the ‘NEAR’ key
Select ‘Alarm Type’
by move the joystick up/down.
And move the joystick right.
Select ‘Alarm Action’
by move the joystick up/down.
And press the ‘NEAR’ key to save.
1
2
MOTION SETUP
Setup the general functions of pan/tilt motions.
PWR UP ACTION
This function enables to resume the last action executed before power
down. Most of actions such as preset, pattern, scan and group are
available for this function but jog actions are not available to resume.
JOG MAX SPEED
Sets maximum jog speed. Jog speed is inversely proportional to zoom
magnification. As zoom magnification goes up, pan/tilt speed goes down.
JOG DIRECTION
If you set this to ‘NORMAL’, the view in the screen is moving same
direction with jog tilting. If ‘INVERSE’ is selected, the view in the screen
is moving reversely.
Moves to ‘ALARM INPUT ACTION’ screen.
Moves to ‘PARKING ACTION SETUP’ screen.
ON / OFF
10/SEC ~ 150/SEC
NORMAL / INVERSE
ALARM INPUT SETUP
If an external sensor is activated, camera will move to
corresponding action.
Alarm Number
Alarm Type
- Sets sensor input type.
- See on 14p for more detailed information.
Alarm Action
Assign counter-action to each alarm input. Among 254 actions, choose
the action as explained below.
1 ~ 8
N.O(Normal Open) / N.C(Normal Close)
NOT USED / HOME / PRESET 1~255(95 excepted)
SCAN 1~8 / PATTERN 1~4 / GROUP 1~8
3
3
ALARM INPUT SETUP - Type Setup
1) Move the joystick up/down to set alarm type.
2) Move the joystick right to set alarm action.
ALARM INPUT SETUP - Alarm Action Setup
1) Move the joystick up/down to set the action(HOME, PRESET,
SCAN, PATTERN, GROUP) and number.
2) Move the joystick left/right to move the focus to set alarm
type, function name and function number.
3) By pressing the near key, save the current setting.