Wechillit Burco User Manual - page 4
Wall mounting your autofill water boiler
•
Before wall mounting your water boiler ensure that the wall you intend to attach
it to is sturdy and that there are no electrical cables/pipes running behind it.
•
Drill holes in the wall to the following dimensions shown below.
Using
IMPORTANT: Always ensure unit is connected correctly to a water supply and the
supply is on before switching the appliance on.
Operating
Safety tap.
1
The tap is locked or unlocked by twisting it so that the closed or opened padlock
symbol is lined up with the white dot on the tap body.
General operation.
2
There are two open positions, one self- holding so that the tap remains open, and
the other self-closing so that the tap closes as soon as the lever is released. To
change the tap position, turn the tap lever through 180º.
3
Open the tap by depressing the tap lever into the horizontal position.
4
Close the tap by returning the lever to a vertical position.
After use
Switch off and isolate from supply. Water may be left in the water boiler when it
is not in use for short periods, for longer periods it should be emptied and cleaned out.
Protective cut-out
WARNING: The only parts you should touch behind the front pane are
the two red isolation valves. Touching any other part will put you in
danger of receiving an electric shock.
WARNING: The protective cutout is only to be reset by a qualified
service engineer
.
The heating element is fitted with a manual resettable thermal cutout which
protects the water boiler from damage if it were to overheat
D
. If your appliance fails
to heat up and/or appears “dead” when switched on, try the following:
Check the water boiler is plugged in to the mains and switched on both at the
plug/spur and the front of the unit. If this does not resolve the problem switch off and
disconnect the appliance. Remove the front panel (see instructions below) and remove
internal cover below the water tank. Reach in carefully and on the underside of the
element, between the two terminals you will see a reset button.
Press this upwards and the thermostat will reset (click). We would always
recommend descling the water boiler after resetting the thermostat as scale build up
is the most common reason for the safetey thermostat operating.
If the safety thermostat activates repeatedly, even after descaling please contact
the customer helpline.
After resetting the cut-out replace the front panel and top plastic lid. Reconnect
to the mains and switch on at plug/spur and on the front of the unit. If the problem
pursists please contact Burco customer helpline.
Cleaning
WARNING: Disconnect from the electrical supply before cleaning and
allow the water boiler to cool.
IMPORTANT Do not immerse the water boiler in water or any other liquids and
take care to keep water away from the mains lead and connections. There are two
ways in which you will need to clean your autofill water boiler:
Externally; to do this follow the external cleaning guidelines (on page 8).
Internally; to do this follow the Easy Descale Procedure (on page 8).
IMPORTANT Do not use any abrasive cleaning fluids or materials.
6
7