WEG Easy Drive CFW10 Quick Start Manual

Other manuals for Easy Drive CFW10: User Manual

Summary of Easy Drive CFW10

  • Page 1

    Publication numer qs005cfw10 phone: 800.894.0412 - fax: 888.723.4773 - web: www.Ctiautomation.Net - email: info@ctiautomation.Net.

  • Page 2

    2 2 power connections: the cfw10 quick start guide is a supplement to help get the cfw10 started quickly using the most common installation and configuration options. This cfw10 quick start guide is not meant to replace the cfw10 user ’s manual. For detailed instructions, safety precautions, proper ...

  • Page 3

    3 3 keypad operation and parameter setup: figure 2 – keypad operation display display description rdy drive is ready to be enabled. Sub power supply voltage too low for drive operation. Dcb drive in dc braking mode. Epp drive is loading factory setting. Note: plus versions of the cfw10 have a speed ...

  • Page 4

    4 4 keypad start/stop (local mode) continued: 4. If parameters were accessed or changed under parameter setup then the last parameter number or value will be displayed. Scroll up or down with the or keys to the read only parameter p002 (frequency proportional value for speed) and press the key to se...

  • Page 5

    5 5 3 wire start/stop (remote mode): parameters: 1. Set di1 (start) to “on” (p263=13). See note below. 2. Set di2 (stop) to “off” (p264=14). 3. Set di4 to “no function” (p266=0). 4. Set p229=1 (dix) if you want the 3 wire control in local mode. 5. Confirm p230=1 (dix) if you want the 3 wire control ...

  • Page 6

    6 publication numer qs005cfw10 6 parameters example: • the following is a typical list of parameter changes that may be needed in addition to the factory default settings (p204=5). P000=5 parameter access (5 = password) p204=5 loads factory default p100=5 acceleration time = 5 seconds p101=10 decele...