Woodbridge Fireplace Inc BONFIRE Owner's Operation And Installation Manual - page 12
TROUBLESHOOTING
WARNING: Turn off the unit
and let cool before servicing. Only
a qualified service person should
service and repair this appliance.
OBSERVED PROBLEM
POSSIBLE CAUSE
REMEDY
age
1. Passage of air/gas across irregular sur-
faces
2. Excessive gas pressure on natural gas
units
1. Incorrect gas supply or pressure
2. Blocked burner orifice or burner mani-
fold ports
3. Improper burner orifice size
Unit is smoking / sooting excessively
(
Note
: It is natural and unavoidable for
appliance sets to produce moderate
levels of carbon (soot) where flames
Burner is excessively noisy
(
Note: The movement and combustion of
gas will create low, unavoidable levels of
noise.)
Burner flame is too low or too high
more flame passage
flame pattern and/or check for proper
orifice sizing
1. Relieve any tight bends or kinks in gas
supply line
2. Check/reset gas regulator pressure
1. Check for proper gas supply pressure
2. Free burner orifice and manifold ports
of any burrs, paint, or other blockage
Note:All troubleshooting items are listed in
order of operation.
contact the media. This is especially true
2.
Improper fuel/air mixture
1.
Excessive flame impingement or block-
1. S
eparate the stones/media to allow
2.
Remove any foreign items from the
3. Verify proper burner orifice sizing.
12
4. Too much media around 4. Clear area in front of pilot assembly,
pilot area. make sure pilot flame is posi-
tioned correctly
3. Insufficient amount of burner media 3. Add burner media.